Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine

被引:5
|
作者
Conrads, Nora [1 ]
Grunz, Jan-Peter [1 ]
Huflage, Henner [1 ]
Luetkens, Karsten Sebastian [1 ]
Feldle, Philipp [1 ]
Grunz, Katharina [2 ]
Koehler, Stefan [3 ,4 ]
Westermaier, Thomas [3 ,5 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Standort Juliusspital, Klinikum Wurzburg Mitte, Dept Orthoped & Trauma Surg, Juliuspromenade 19, D-97070 Wurzburg, Germany
[3] Univ Hosp Wurzburg, Dept Neurosurg, Josef Schneider Str 11, D-97080 Wurzburg, Germany
[4] Die Neurochirurg Praxis, Eichhornstr 28, D-97070 Wurzburg, Germany
[5] Helios Amper Klinikum Dachau, Dept Neurosurg, Krankenhausstr 15, D-85221 Dachau, Germany
关键词
Pedicle screws; Vertebral pedicles; Fluoroscopy; Neuronavigation; Spine; FREE-HAND; NAVIGATION; GUIDANCE; SURGERY;
D O I
10.1007/s00402-022-04514-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities. Materials and methods Posterior instrumentation procedures between 2010 and 2015 were retrospectively analyzed. Pedicle screws were placed using 3D rotational fluoroscopy and neuronavigation. Accuracy of screw placement was assessed using a 6-grade scoring system. In addition, screw length was analyzed in relation to the vertebral body diameter. Intra- and postoperative revision rates were recorded. Results Thoracic and lumbar spine surgery was performed in 285 patients. Of 1704 pedicle screws, 1621 (95.1%) showed excellent positioning in 3D rotational fluoroscopy imaging. The lateral rim of either pedicle or vertebral body was protruded in 25 (1.5%) and 28 screws (1.6%), while the midline of the vertebral body was crossed in 8 screws (0.5%). Furthermore, 11 screws each (0.6%) fulfilled the criteria of full lateral and medial displacement. The median relative screw length was 92.6%. Intraoperative revision resulted in excellent positioning in 58 of 71 screws. Follow-up surgery due to missed primary malposition had to be performed for two screws in the same patient. Postsurgical symptom relief was reported in 82.1% of patients, whereas neurological deterioration occurred in 8.9% of cases with neurological follow-up. Conclusions Combination of neuronavigation and 3D rotational fluoroscopy control ensures excellent accuracy in pedicle screw positioning. As misplaced screws can be detected reliably and revised intraoperatively, repeated surgery for screw malposition is rarely required.
引用
收藏
页码:3007 / 3013
页数:7
相关论文
共 50 条
  • [31] A multi-level drill guide template improves the accuracy of pedicle screw placement in lumbar spine
    Ge, D. -W.
    Yang, L.
    Chen, X.
    Tang, J.
    Chen, H. -T.
    Li, H. -J.
    Sui, T.
    Zhuang, Y.
    Zheng, S. -N.
    Cao, X. -J.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2018, 22 (12) : 3643 - 3648
  • [32] Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine
    Rajan, Vinod V.
    Kamath, Vijay
    Shetty, Ajoy Prasad
    Rajasekaran, S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2010, 44 (02) : 163 - 168
  • [33] Accuracy of pedicle screw placement in thoracic spine fractures - Part II: A retrospective analysis of 278 pedicle screws using computed tomographic scans
    Zdichavsky M.
    Blauth M.
    Knop C.
    Lotz J.
    Krettek C.
    Bastian L.
    European Journal of Trauma, 2004, 30 (4): : 241 - 247
  • [34] The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine
    Bredow, J.
    Oppermann, J.
    Kraus, B.
    Schiller, P.
    Schiffer, G.
    Sobottke, R.
    Eysel, P.
    Koy, T.
    EUROPEAN SPINE JOURNAL, 2015, 24 (12) : 2967 - 2976
  • [35] The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine
    J. Bredow
    J. Oppermann
    B. Kraus
    P. Schiller
    G. Schiffer
    R. Sobottke
    P. Eysel
    T. Koy
    European Spine Journal, 2015, 24 : 2967 - 2976
  • [36] Percutaneous Pedicle Screw Placement in the Lumbar Spine A Comparison Study Between the Novel Guidance System and the Conventional Fluoroscopy Method
    Gu, Guangfei
    Zhang, Hailong
    He, Shisheng
    Cai, Xiaobing
    Gu, Xin
    Jia, Jianbo
    Fu, Qingsong
    Zhou, Xu
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (09): : E522 - E527
  • [37] Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine
    Kageyama, Hiroto
    Yoshimura, Shinichi
    Uchida, Kazutaka
    Iida, Tomoko
    NEUROLOGIA MEDICO-CHIRURGICA, 2017, 57 (09) : 481 - 488
  • [38] Computed-tomography-based anatomical study to assess feasibility of pedicle screw placement in the lumbar and lower thoracic pediatric spine
    Shaikh, Kashif A.
    Bennett, Garrett M.
    White, Ian K.
    Bullis, Carli L.
    Fulkerson, Daniel H.
    CHILDS NERVOUS SYSTEM, 2012, 28 (10) : 1743 - 1754
  • [39] Computed-tomography-based anatomical study to assess feasibility of pedicle screw placement in the lumbar and lower thoracic pediatric spine
    Kashif A. Shaikh
    Garrett M. Bennett
    Ian K. White
    Carli L. Bullis
    Daniel H. Fulkerson
    Child's Nervous System, 2012, 28 : 1743 - 1754
  • [40] Accuracy of pedicle screw insertion in the thoracic and lumbar spine: a comparative study between percutaneous screw insertion and conventional open technique
    Hiroko Ikeuchi
    Ko Ikuta
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 1195 - 1202