Determination of load transfer characteristics to connections between cold-formed steel truss and supporting system

被引:0
|
作者
Choong, Kok Keong [1 ]
De'nan, Fatimah [1 ]
Chew, Seen Hooi [1 ]
Hashim, Nor Salwani [1 ]
机构
[1] Univ Sains Malaysia, Sch Civil Engn, Engn Campus, Seri Ampangan, Nibong Tebal, Malaysia
关键词
Cold-formed steel; Finite element method; Connections; DESIGN;
D O I
10.1108/WJE-03-2022-0121
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Purpose Recently, the utilization of cold-formed steel (CFS) roof truss systems and different types of other combination structural support systems, such as concrete or hot-rolled steel support, becomes more frequently used. This paper aims to identify the load transfer characteristics of three different design details for cold-formed truss to supporting system connections and to propose simplified modelling approach for practices. Design/methodology/approach Simplification modelling of connection design could be proposed for practical purpose based on the load transfer characteristics obtained from detailed study using finite element method. A cold-formed roof truss system with connection is modelled using line elements. However, the supporting system is not modelled in this work. Three types of connection involve, which are five pieces of CFS L-angle brackets, one-piece of CFS L-angle brackets and three types of bolts connection are modelled. Findings The results of analysis show that the connections located on the loaded side experienced higher reactions than those far from loaded side. From the result, it is also found that the option of "Fixed But" support condition in STAAD.Pro with translational degree of freedom being restrained is the most suitable way to represent the CFS L-angle brackets design for Type 1 connection for use in truss modelled using line elements. Originality/value Such increase in usage necessitates an appropriate connection detailing depending on the behaviour of the connection.
引用
收藏
页码:1239 / 1248
页数:10
相关论文
共 50 条
  • [21] Analysis and design of lapped connections between cold-formed steel Z sections
    Chung, KF
    Ho, HC
    THIN-WALLED STRUCTURES, 2005, 43 (07) : 1071 - 1090
  • [22] Bearing strength of cold-formed steel bolted connections with a gap
    Yu, Cheng
    Panyanouvong, Mark Xouphab
    THIN-WALLED STRUCTURES, 2013, 67 : 110 - 115
  • [23] Behavior of low ductility steels in cold-formed steel connections
    Seleim, S
    LaBoube, R
    THIN-WALLED STRUCTURES, 1996, 25 (02) : 135 - 151
  • [24] Behavior of screw connections in sheathed cold-formed steel walls
    Abu-Hamd, Metwally
    Tawfik, Nouran M.
    Abu-Hamd, Metwally (abuhamd@eng.cu.edu.eg), 1600, Elsevier Ltd (187):
  • [25] Performance evaluation of cold-formed steel spot weld connections
    Rajić, Andrea
    Lukačević, Ivan
    Ćurković, Ivan
    Žuvelek, Vlaho
    ce/papers, 2023, 6 (3-4) : 1959 - 1964
  • [26] Structural Behavior of Screwed Connections in Cold-Formed Steel Beams
    Minh Toan Huynh
    Cao Hung Pham
    Rogers, Cohn A.
    Hancoc, Gregory J.
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (03)
  • [27] Behavior of screw connections in sheathed cold-formed steel walls
    Abu-Hamd, Metwally
    Tawfik, Nouran M.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 187
  • [28] Structural behavior of cold-formed stainless steel bolted connections
    Cai, Yancheng
    Young, Ben
    THIN-WALLED STRUCTURES, 2014, 83 : 147 - 156
  • [29] Structural performance of cold-formed steel structures with bolted connections
    Chung, KF
    ADVANCES IN STRUCTURAL ENGINEERING, 2005, 8 (03) : 231 - 245
  • [30] Serviceability limit state for cold-formed steel bolted connections
    LaBoube, RA
    Yu, WW
    Carril, JL
    CONNECTIONS IN STEEL STRUCTURES III: BEHAVIOUR, STRENGTH AND DESIGN, 1996, : 403 - 411