Validation of a new automated irradiation system for off-line ECP

被引:0
|
作者
Del Fante, Claudia [1 ]
Klersy, Catherine [2 ]
Barone, Eugenio [1 ]
De Vitis, Simona [1 ]
Troletti, Daniela [1 ]
Mortellaro, Cristina [3 ]
Musella, Valeria [2 ]
Perotti, Cesare [3 ]
机构
[1] Fdn IRCCS Policlin San Matteo, Immunohaematol & Transfus Serv, Cell Manipulat Lab, Viale Golgi 19, I-27100 Pavia, Italy
[2] Fdn IRCCS Policlin San Matteo, Biostat & Clin trial Ctr, Pavia, Italy
[3] Fdn IRCCS Policlin San Matteo, Immunohaematol & Transfus Serv, Pavia, Italy
关键词
Extracorporeal Photopheresis; ECP off-line technique; Quality controls; Photopheresis; UV -A irradiator device; transplantation; VERSUS-HOST-DISEASE; REGULATORY T-CELLS; EXTRACORPOREAL PHOTOPHERESIS; QUALITY-CONTROL; PHOTOCHEMOTHERAPY; INDUCTION; APOPTOSIS; PROLIFERATION; MODULATION;
D O I
10.1016/j.transci.2023.103724
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Extracorporeal photopheresis (ECP) is a cell therapy originally employed for cutaneous T cell lymphoma and later for GvHD, solid organ rejection and other immunological diseases demonstrating an excellent safety profile. Mononuclear cell (MNCs) apoptosis triggered by UV-A light irradiation in the presence of 8-methoxypsoralene has a key role in priming the cells, ultimately leading to immunomodulation. We report preliminary data about an evaluation of the new automated irradiator device LUMILIGHT (Pelham Crescent srl) for off-line ECP. Fifteen MNCs samples collected by apheresis from 15 adult patients undergoing ECP at our Center were cultured immediately after irradiation along with untreated samples and evaluated at 24, 48 and 72 h timepoints for T cell apoptosis and viability by flow cytometry with Annexin V and Propide Iodidum staining. Post irradiation Hematocrit (HCT), calculated by the device, was compared with that of the automated cell counter. Bacterial contamination was also tested. In irradiated samples after 24-48 and 72 h, the average total apoptosis was 47 %, 70 % and 82 %, respectively, showing a significant difference from untreated samples; residual viable lymphocytes at 72 h were, on average, 18 %. The greatest initiation of apoptosis occurred from 48 h of irradiation onwards. Average early apoptosis of irradiated samples decreased over time (26 %, 17 % and 10 % at 24, 48 and 72 h, respectively). HCT measured by LUMILIGHT was over-estimated, possibly due to the low pre irradiation red blood cell contamination. Bacterial tests resulted negative. Our study showed the LUMILIGHT device to be a valid instrument for MNCs irradiation with good handling and no major technical problems as well as no adverse events in the patients. Our data need to be confirmed in larger studies.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] AUTOMATED ANALYTICAL SYSTEMS AND DATATERMINALS - OFF-LINE DATASYSTEM DEVICE
    CHRISTIANSEN, H
    GRIMNES, S
    KULAS, FR
    WAALER, T
    PHARMACEUTICA ACTA HELVETIAE, 1971, 46 (10-1): : 677 - +
  • [22] An off-line cursive handwriting recognition system
    Senior, AW
    Robinson, AJ
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1998, 20 (03) : 309 - 321
  • [23] OFF-LINE CLINICAL CHEMISTRY COMPUTER SYSTEM
    VITEK, P
    CHIU, S
    HEALY, MJR
    LUCAS, D
    ANNALS OF CLINICAL BIOCHEMISTRY, 1974, 11 (MAY) : 86 - 90
  • [24] Off-line sheet glass coating system
    Buchanan, JL
    McKown, C
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1997, 218 : 179 - 184
  • [26] OFF-LINE SYSTEM FOR DATA ACQUISITION AND ANALYSIS
    MASTER, RC
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1971, 48 (05) : 191 - &
  • [27] Validation, off-line programming and optimisation of industrial control logic
    Danielsson, F
    Moore, P
    Eriksson, P
    MECHATRONICS, 2003, 13 (06) : 571 - 585
  • [28] OFF-LINE SYSTEM FOR MEASUREMENT OF NITROUS-OXIDE CONCENTRATION IN GASES LEAVING THE IRRADIATION CHAMBER
    LICKI, J
    CHMIELEWSKI, AG
    RADZIO, B
    RADIATION PHYSICS AND CHEMISTRY, 1995, 45 (06): : 1035 - 1038
  • [29] Extracorporeal photopheresis - comparison of the in-line and off-line system
    Lanska, M.
    Radocha, J.
    Visek, B.
    Zavrelova, A.
    Horacek, J. M.
    Stevkova, J.
    Zak, P.
    BONE MARROW TRANSPLANTATION, 2022, 57 (SUPPL 1) : 404 - 404
  • [30] Off-line accountability
    Mehta, M
    INDUSTRIAL ENGINEER, 2006, 38 (04): : 53 - 53