Validation of a new automated irradiation system for off-line ECP

被引:0
|
作者
Del Fante, Claudia [1 ]
Klersy, Catherine [2 ]
Barone, Eugenio [1 ]
De Vitis, Simona [1 ]
Troletti, Daniela [1 ]
Mortellaro, Cristina [3 ]
Musella, Valeria [2 ]
Perotti, Cesare [3 ]
机构
[1] Fdn IRCCS Policlin San Matteo, Immunohaematol & Transfus Serv, Cell Manipulat Lab, Viale Golgi 19, I-27100 Pavia, Italy
[2] Fdn IRCCS Policlin San Matteo, Biostat & Clin trial Ctr, Pavia, Italy
[3] Fdn IRCCS Policlin San Matteo, Immunohaematol & Transfus Serv, Pavia, Italy
关键词
Extracorporeal Photopheresis; ECP off-line technique; Quality controls; Photopheresis; UV -A irradiator device; transplantation; VERSUS-HOST-DISEASE; REGULATORY T-CELLS; EXTRACORPOREAL PHOTOPHERESIS; QUALITY-CONTROL; PHOTOCHEMOTHERAPY; INDUCTION; APOPTOSIS; PROLIFERATION; MODULATION;
D O I
10.1016/j.transci.2023.103724
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Extracorporeal photopheresis (ECP) is a cell therapy originally employed for cutaneous T cell lymphoma and later for GvHD, solid organ rejection and other immunological diseases demonstrating an excellent safety profile. Mononuclear cell (MNCs) apoptosis triggered by UV-A light irradiation in the presence of 8-methoxypsoralene has a key role in priming the cells, ultimately leading to immunomodulation. We report preliminary data about an evaluation of the new automated irradiator device LUMILIGHT (Pelham Crescent srl) for off-line ECP. Fifteen MNCs samples collected by apheresis from 15 adult patients undergoing ECP at our Center were cultured immediately after irradiation along with untreated samples and evaluated at 24, 48 and 72 h timepoints for T cell apoptosis and viability by flow cytometry with Annexin V and Propide Iodidum staining. Post irradiation Hematocrit (HCT), calculated by the device, was compared with that of the automated cell counter. Bacterial contamination was also tested. In irradiated samples after 24-48 and 72 h, the average total apoptosis was 47 %, 70 % and 82 %, respectively, showing a significant difference from untreated samples; residual viable lymphocytes at 72 h were, on average, 18 %. The greatest initiation of apoptosis occurred from 48 h of irradiation onwards. Average early apoptosis of irradiated samples decreased over time (26 %, 17 % and 10 % at 24, 48 and 72 h, respectively). HCT measured by LUMILIGHT was over-estimated, possibly due to the low pre irradiation red blood cell contamination. Bacterial tests resulted negative. Our study showed the LUMILIGHT device to be a valid instrument for MNCs irradiation with good handling and no major technical problems as well as no adverse events in the patients. Our data need to be confirmed in larger studies.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] AUTOMATED BORDER DETECTION - OFF-LINE VALIDATION OF SERIAL INTRAOPERATIVE MEASUREMENTS
    PERRINO, AC
    LUTHER, MA
    OCONNOR, TZ
    COHEN, IS
    ANESTHESIOLOGY, 1994, 81 (3A) : A522 - A522
  • [2] The all new kajaanipaperlab automated paper & board testing system with completely new generation for off-line and at-line
    Process Automation Systems, Metso Automation, Japan
    Kami Pa Gikyoshi, 1600, 3 (85-89):
  • [3] A new untraceable off-line electronic cash system
    Eslami, Ziba
    Talebi, Mehdi
    ELECTRONIC COMMERCE RESEARCH AND APPLICATIONS, 2011, 10 (01) : 59 - 66
  • [4] The COMPASS off-line system
    Martin, A
    COMPUTER PHYSICS COMMUNICATIONS, 2001, 140 (1-2) : 82 - 91
  • [5] OFF-LINE SUPPORT SYSTEM
    不详
    ELECTRICAL COMMUNICATION, 1980, 55 (02): : 44 - 48
  • [6] Evaluation of On- and Off-Line Bioluminescence Tomography System for Focal Irradiation Guidance
    Zhang, B.
    Wang, K.
    Iordachita, I.
    Reyes, J.
    Tran, P.
    Wong, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3198 - 3198
  • [7] Evaluation of On- and Off-Line Bioluminescence Tomography System for Focal Irradiation Guidance
    Zhang, Bin
    Wong, John W.
    Iordachita, Iulian I.
    Reyes, Juvenal
    Nugent, Katriana
    Tran, Phuoc T.
    Tuttle, Stephen W.
    Koumenis, Constantinos
    Wang, Ken Kang-Hsin
    RADIATION RESEARCH, 2016, 186 (06) : 592 - 601
  • [8] Automated versus off-line prefractionation of proteomics samples
    Axelman, Johan
    Hoepker, Hans-Rudolf
    Jonsson, Andreas
    Poetsch, Stephan
    Renlund, Staffan
    MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (10) : S297 - S297
  • [9] Off-line validation of power network branch parameters
    Do Coutto Filho, M. B.
    Stacchini de Souza, J. C.
    Meza, E. B. M.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2008, 2 (06) : 892 - 905
  • [10] Off-line Handwritten Thai Name Recognition for Student Identification in an Automated Assessment System
    Suwanwiwat, Hemmaphan
    Vu Nguyen
    Blumenstein, Michael
    Pal, Umapada
    PROCEEDINGS OF THE 2014 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2014, : 2347 - 2353