A study on the immediate effects of enhanced external counterpulsation on physiological coupling

被引:1
|
作者
Liu, Hongyun [1 ,2 ]
Liang, Hui [3 ]
Yu, Xiaohua [1 ,2 ]
Han, Yi [1 ,2 ]
Wang, Guojing [1 ,2 ]
Yan, Muyang [3 ]
Wang, Weidong [1 ,2 ]
Li, Shijun [4 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Res Ctr Biomed Engn, Med Innovat Res Div, Beijing, Peoples R China
[2] Minist Ind & Informat Technol, Key Lab Biomed Engn & Translat Med, Beijing, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Hyperbar Oxygen, Beijing, Peoples R China
[4] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Diagnost Radiol, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
enhanced external counterpulsation; physiological coupling; immediate effects; hemodynamics; phase synchronization; BLOOD-PRESSURE; HEART-RATE; SYNCHRONIZATION; BAROREFLEX;
D O I
10.3389/fnins.2023.1197598
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
IntroductionEnhanced external counterpulsation (EECP) is a non-invasive assisted circulation technique for its clinical application in the rehabilitation and management of ischemic cardiovascular and cerebrovascular diseases, which has complex physiological and hemodynamic effects. However, the effects of EECP on the coupling of physiological systems are still unclear. We aimed to investigate the immediate effects of EECP on the coupling between integrated physiological systems such as cardiorespiratory and cardiovascular systems. MethodsBased on a random sham-controlled design, simultaneous electrocardiography, photoplethysmography, bio-electrical impedance, and continuous hemodynamic data were recorded before, during and after two consecutive 30 min EECP in 41 healthy adults. Physiological coupling strength quantified by phase synchronization indexes (PSI), hemodynamic measurements and heart rate variability indices of 22 subjects (female/male: 10/12; age: 22.6 +/- 2.1 years) receiving active EECP were calculated and compared with those of 19 sham control subjects (female/male: 7/12; age: 23.6 +/- 2.5 years). ResultsImmediately after the two consecutive EECP interventions, the physiological coupling between respiratory and cardiovascular systems PSIRES-PTT (0.34 +/- 0.14 vs. 0.49 +/- 0.17, P = 0.002), the physiological coupling between cardiac and cardiovascular systems PSIIBI-PTT (0.41 +/- 0.14 vs. 0.52 +/- 0.16, P = 0.006) and the total physiological coupling PSItotal (1.21 +/- 0.35 vs. 1.57 +/- 0.49, P = 0.005) in the EECP group were significantly lower than those before the EECP intervention, while the physiological coupling indexes in the control group did not change significantly (P > 0.05). ConclusionOur study provides evidence that the PSI is altered by immediate EECP intervention. We speculate that the reduced PSI induced by EECP may be a marker of disturbed physiological coupling. This study provides a new method for exploring the mechanism of EECP action and may help to further optimize the EECP technique.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Effects of External Counterpulsation Therapy on Physiological Fitness Indicators in Healthy Adults
    Thor, Dianna
    Balasekaran, Govindasamy
    Kawabata, Masato
    McLaren, Jason
    Bert, Anthony
    Bin Fang, Jia
    Teng, Phillis
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 431 - 431
  • [12] Acute hemodynamic effects and angina improvement with enhanced external counterpulsation
    Stys, T
    Lawson, WE
    Hui, JCK
    Lang, G
    Liuzzo, J
    Cohn, PF
    ANGIOLOGY, 2001, 52 (10) : 653 - 658
  • [13] Acute Effects of Enhanced External Counterpulsation in Adults With Fontan Circulation
    Wu, Fred M.
    Misra, Amrit
    Valle, Christopher
    Duncan, Madeline E.
    Ghelani, Sunil J.
    Gerhard-Herman, Marie D.
    Lipsitz, Stuart R.
    Rathod, Rahul H.
    Gurvitz, Michelle Z.
    Singh, Michael N.
    Valente, Anne M.
    CIRCULATION, 2023, 148
  • [14] Effects of enhanced external counterpulsation on internal mammary artery flow: Comparison with intraaortic balloon counterpulsation
    Katz, WE
    Gulati, V
    Feldman, AM
    Crawford, L
    Peron, M
    Soran, O
    Gorcsan, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 85A - 85A
  • [15] The study of the Enhanced External Counterpulsation system based on smart clothes
    Wu, Ting-Kai
    Ku, Wun-Ye
    Yang, Chih-Yu
    Lin, Wen-Yen
    Lin, Chung-Chih
    Liou, Yi-Shin
    Lee, Ming-Yih
    Tsai, Tsai-Hsuan
    2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2016, : 125 - 129
  • [16] Experiment study of the effect of enhanced external counterpulsation on shear stress
    Wang, H.
    Zheng, Z.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2001, 18 (04): : 520 - 522
  • [17] A historical overview of enhanced external counterpulsation
    DeMaria, AN
    CLINICAL CARDIOLOGY, 2002, 25 (12) : 3 - 5
  • [18] Enhanced external counterpulsation: Mechanism of action
    Feldman, AM
    CLINICAL CARDIOLOGY, 2002, 25 (12) : 11 - 15
  • [19] Numerical Simulation of Enhanced External Counterpulsation
    Edwin T. Ozawa
    Karen E. Bottom
    Xinshu Xiao
    Roger D. Kamm
    Annals of Biomedical Engineering, 2001, 29 : 284 - 297
  • [20] Numerical simulation of enhanced external counterpulsation
    Ozawa, ET
    Bottom, KE
    Xiao, XS
    Kamm, RD
    ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (04) : 284 - 297