Experimental study on the flexible peak shaving with pulverized coal self-preheating technology under load variability

被引:3
|
作者
Wang, Hongshuai [1 ,2 ]
Ouyang, Ziqu [1 ,2 ,4 ]
Ding, Hongliang [1 ,2 ]
Su, Kun [1 ,2 ]
Zhang, Jinyang [1 ,3 ]
Hu, Yujie [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Jiangsu Univ, Zhenjiang 212013, Peoples R China
[4] Chinese Acad Sci, Inst Engn Thermophys, 11 Beisihuanxi Rd, Beijing 100190, Peoples R China
关键词
Coal combustion; Peak shaving; Self-preheating; Load-stabilization basis; Load change rate; FIRED POWER-PLANTS; COMBUSTION CHARACTERISTICS; OPERATIONAL FLEXIBILITY; ANTHRACITE COMBUSTION; NOX EMISSION; BOILER; VOLATILE; AIR; SPECTROSCOPY; FLAME;
D O I
10.1016/j.energy.2023.129830
中图分类号
O414.1 [热力学];
学科分类号
摘要
The integration of renewable energy sources into power grids has led to power fluctuations, necessitating coal-fired power units to provide flexible peak shaving. The pulverized coal self-preheating technology can potentially provide broad-load regulation and rapidly respond to load changes. In this study, the impact of the self-preheating technology on fuel preheating modification, combustion characteristics, and NOx emissions are investigated. Load-stabilization bases are proposed based on preheating temperature, preheated coal gas composition, combustion temperature, and flue gas emissions. Load change rates are calculated using these bases to character the load response. The results demonstrate that the preheated fuel has similar properties as the highly reactive gaseous fuel and exhibits excellent ignition and combustion performances at 25 % load. Pre-heating treatment improves combustion efficiency, and burnout ratio and reduces NOx emissions. The NOx concentration approaches the ultra-low emission standard at 50 % load. Four load-stabilization bases, covering the preheating and combustion sides, comprehensively characterize the load response performance. The rates based on preheating indicators and combustion indicators maximize to 3.30 %/minute and 2.71 %/minute, respectively. The load change rate in the ramp-up phase is higher than that in the ramp-down phase, which is related to the effective internal heat storage carrier and external thermal insulation conditions. The driving force formed by high load step ranges and the deviation from the full load capacity are conducive to increasing the load change rates.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Experimental study on preheating combustion characteristics and NOx emission of pulverized coal based on an entrained-flow gasifier
    Tan H.
    Wang X.
    Zhou B.
    Zhou S.
    Wang Y.
    Wang X.
    Meitan Xuebao/Journal of the China Coal Society, 2023, 48 (11): : 4192 - 4204
  • [32] Experimental study on surface potential effect of coal under load
    Wang En-Yuan
    Li Zhong-Hui
    Liu Zhen-Tang
    Li Yan-Na
    Song Xiao-Yan
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2009, 52 (05): : 1318 - 1325
  • [33] Experimental study on combustion characteristics of a 40 MW pulverized coal boiler based on a new low NOx burner with preheating function
    Tang, Hong
    Liu, Zuodong
    Han, Xiaoju
    Shen, Xueqiang
    Liu, Yuqiu
    Wang, Siyuan
    Xu, Zhiming
    ENERGY, 2024, 305
  • [34] Experimental study on optimizing parameters of flexible reinforcement technology of coal wall
    Yang S.
    Yang Y.
    Meitan Xuebao/Journal of the China Coal Society, 2019, 44 (09): : 2622 - 2631
  • [35] Experimental investigation on co-firing residual char and pulverized coal under MILD combustion using low-temperature preheating air
    Hu, Fan
    Li, Pengfei
    Zhang, Tai
    Zu, Daohua
    Cheng, Pengfei
    Liu, Yaowei
    Mi, Jianchun
    Liu, Zhaohui
    ENERGY, 2022, 244
  • [36] The combustion and NOx emission characteristics of the ultra-low volatile fuel using the novel pulverized coal self-sustained preheating combustion technology
    Song, Wenhao
    Ouyang, Ziqu
    Wang, Minghao
    Li, Shiyuan
    Liu, Jingzhang
    Yu, Qiang
    Liu, Wen
    Zhu, Shujun
    FUEL, 2020, 271 (271)
  • [37] Experimental study on ignition characteristics of pulverized coal under high-temperature oxygen condition
    Liu, G. W.
    Liu, Y. H.
    Dong, P.
    2016 INTERNATIONAL CONFERENCE ON NEW ENERGY AND FUTURE ENERGY SYSTEM (NEFES 2016), 2016, 40
  • [38] Experimental Study on Characteristics of Pulverized Coal Combustion Under the High-speed Jet Condition
    Huang, Wenshi
    Zhang, Yang
    Zhang, Qi
    Jiang, Fangzhou
    Wu, Yuxin
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (08): : 2119 - 2126
  • [39] Experimental Study on Crushing Characteristic of Coal and Gangue under Impact Load
    Zhou, Jiawei
    Liu, Yu
    Du, Changlong
    Wang, Furong
    INTERNATIONAL JOURNAL OF COAL PREPARATION AND UTILIZATION, 2016, 36 (05) : 272 - 282
  • [40] Numerical Study of Furnace Process of a 600 MW Pulverized Coal Boiler under Low load with SNCR Application
    Cao, Q. X.
    Shi, Y.
    Liu, H.
    Yang, C. H.
    Wu, S. H.
    CLEANER COMBUSTION AND SUSTAINABLE WORLD, 2012, : 108 - 112