Performance of Computed Tomographic Angiography-Based Aortic Valve Area for Assessment of Aortic Stenosis

被引:4
|
作者
Ash, Jerry [1 ]
Sandhu, Gurmandeep S. [1 ,2 ]
Arriola-Montenegro, Jose [2 ]
Agakishiev, Dzhalal [2 ]
Clavel, Marie-Annick [3 ]
Pibarot, Philippe [3 ]
Duval, Sue [1 ]
Nijjar, Prabhjot S. [1 ,4 ]
机构
[1] Univ Minnesota, Med Sch, Dept Med, Cardiovasc Div, Minneapolis, MN USA
[2] Univ Minnesota, Med Sch, Dept Med, Minneapolis, MN USA
[3] Laval Univ, Quebec Heart & Lung Inst, Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
[4] Univ Minnesota, Med Ctr, 420 Delaware St SE,MMC 508, Minneapolis, MN 55455 USA
来源
关键词
aortic stenosis; computed tomography; echocardiography;
D O I
10.1161/JAHA.123.029973
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundA total of 40% of patients with severe aortic stenosis (AS) have low-gradient AS, raising uncertainty about AS severity. Aortic valve calcification, measured by computed tomography (CT), is guideline-endorsed to aid in such cases. The performance of different CT-derived aortic valve areas (AVAs) is less well studied. Methods and ResultsConsecutive adult patients with presumed moderate and severe AS based on echocardiography (AVA measured by continuity equation on echocardiography <1.5 cm(2)) who underwent cardiac CT were identified retrospectively. AVAs, measured by direct planimetry on CT (AVA(CT)) and by a hybrid approach (AVA measured in a hybrid manner with echocardiography and CT [AVA(Hybrid)]), were measured. Sex-specific aortic valve calcification thresholds (& GE;1200 Agatston units in women and & GE;2000 Agatston units in men) were applied to adjudicate severe or nonsevere AS. A total of 215 patients (38.0% women; mean & PLUSMN;SD age, 78 & PLUSMN;8 years) were included: normal flow, 59.5%; and low flow, 40.5%. Among the different thresholds for AVA(CT) and AVA(Hybrid), diagnostic performance was the best for AVA(CT) <1.2 cm(2) (sensitivity, 85%; specificity, 26%; and accuracy, 72%), with no significant difference by flow status. The percentage of patients with correctly classified AS severity (correctly classified severe AS+correctly classified moderate AS) was as follows; AVA measured by continuity equation on echocardiography <1.0 cm(2), 77%; AVA(CT) <1.2 cm(2), 73%; AVA(CT) <1.0 cm(2), 58%; AVA(Hybrid) <1.2 cm(2), 59%; and AVA(Hybrid) <1.0 cm(2), 45%. AVA(CT) cut points of 1.52 cm(2) for normal flow and 1.56 cm(2) for low flow, provided 95% specificity for excluding severe AS. ConclusionsCT-derived AVAs have poor discrimination for AS severity. Using an AVA(CT) <1.2-cm(2) threshold to define severe AS can produce significant error. Larger AVA(CT) thresholds improve specificity.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Variation of computed tomographic angiography–based fractional flow reserve after transcatheter aortic valve implantation
    Yi Zhang
    Tian-Yuan Xiong
    Yi-Ming Li
    Fang-Yang Huang
    Yong Peng
    Qiao Li
    Jia-Fu Wei
    Sen He
    Kun-Lin Cao
    Yuan Feng
    Bo Xu
    Darren Mylotte
    Mao Chen
    European Radiology, 2021, 31 : 6220 - 6229
  • [22] Relationship Between Aortic Valve Area Assessment From Transthoracic Echocardiogram and Cardiac Computed Tomographic Angiogram
    Sankaramangalam, Kesavan P.
    Sulaiman, Samian
    Ludhwani, Dipesh
    Uqaily, Muhammad
    Zeb, Irfan
    CIRCULATION, 2022, 146
  • [23] NONINVASIVE ASSESSMENT OF VALVE AREA IN PATIENTS WITH AORTIC-STENOSIS
    OHLSSON, J
    WRANNE, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (03) : 501 - 508
  • [24] Comparison of Echocardiography and CT for the Assessment of Aortic Stenosis Valve Area
    Habis, Michel
    Capderou, Andre
    Ghostine, Said
    Paul, Jean-Francois
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (09) : 1115 - 1116
  • [25] Assessment of aortic valve area on cardiac computed tomography and doppler echocardiography: differences and clinical significance in symptomatic bicuspid aortic stenosis
    Kim, K.
    Lee, S. J.
    Seo, J.
    Suh, Y. J.
    Cho, I.
    Hong, G. R.
    Ha, J. W.
    Kim, Y. J.
    Shim, C. Y.
    EUROPEAN HEART JOURNAL, 2022, 43 : 143 - 143
  • [26] Assessment of aortic valve area on cardiac computed tomography in symptomatic bicuspid aortic stenosis: Utility and differences from Doppler echocardiography
    Kim, Kyu
    Lee, Soo Ji
    Seo, Jiwon
    Suh, Young Joo
    Cho, Iksung
    Hong, Geu-Ru
    Ha, Jong-Won
    Kim, Young Jin
    Shim, Chi Young
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [27] THE RELATIONSHIP OF AORTIC VALVE CALCIFICATION AND AORTIC VALVE AREA ON COMPUTED TOMOGRAPHY
    Foley, R.
    Lyen, S.
    Manghat, N.
    Hamilton, M.
    HEART, 2020, 106 : A8 - A8
  • [28] Sixteen slice computed tomography for assessment of aortic valve calcification as a marker of aortic stenosis severity
    Koos, R
    Mahnken, AH
    Sinha, AM
    Mühlenbruch, G
    Wildberger, JE
    Hoffmann, R
    Kühl, HP
    EUROPEAN HEART JOURNAL, 2004, 25 : 377 - 377
  • [29] Morphometry of the aortic arch and its branches. A computed tomography angiography-based study
    Tapia-Nanez, M.
    Landeros-Garcia, G. A.
    Sada-Trevino, M. A.
    Pinales-Razo, R.
    Quiroga-Garza, A.
    Fernandez-Rodarte, B. A.
    Elizondo-Omana, R. E.
    Guzman-Lopez, S.
    FOLIA MORPHOLOGICA, 2021, 80 (03) : 575 - 582
  • [30] Demonstration of a hypoplastic aortic arch by computed tomographic angiography
    Goksel, Onur Selcuk
    Ugurlucan, Murat
    Tireli, Emin
    Dayioglu, Enver
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2007, 35 (01): : 57 - 57