Diagnostic accuracy of magnetic resonance elastography and point-shear wave elastography for significant hepatic fibrosis screening: Systematic review and meta-analysis

被引:6
|
作者
Schambeck, Joao Paulo L. [1 ,2 ]
Forte, Gabriele C. [2 ,3 ]
Goncalves, Luana M. [1 ,2 ]
Stuker, Guilherme [2 ]
Kotlinski, Joao Bruno F. [3 ]
Tramontin, Giacomo [2 ]
Altmayer, Stephan [1 ]
Watte, Guilherme [4 ]
Hochhegger, Bruno [1 ,2 ,4 ,5 ]
机构
[1] Pontificia Univ Catolica Rio Grande do Sul, Postgrad Program Med & Hlth Sci, Porto Alegre, RS, Brazil
[2] Pontificia Univ Catolica Rio Grande do Sul, Hosp Sao Lucas, Dept Radiol, Porto Alegre, RS, Brazil
[3] Pontificia Univ Catolica Rio Grande do Sul, Fac Med, Porto Alegre, RS, Brazil
[4] LABIMED, Dept Radiol, Med Imaging Res Lab, Porto Alegre, RS, Brazil
[5] Fed Univ Hlth Sci Porto Alegre, Dept Diagnost Methods, Porto Alegre, RS, Brazil
来源
PLOS ONE | 2023年 / 18卷 / 02期
关键词
RADIATION-FORCE IMPULSE; CHRONIC VIRAL-HEPATITIS; LIVER FIBROSIS; NONINVASIVE ASSESSMENT; TRANSIENT ELASTOGRAPHY; MR ELASTOGRAPHY; ULTRASOUND ELASTOGRAPHY; ARFI; PERFORMANCE; STEATOSIS;
D O I
10.1371/journal.pone.0271572
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The hepatic diseases are extremely common in clinical practice. The correct classification of liver fibrosis is extremely important, as it influences therapy and predicts disease outcomes. The purpose of this study is to compare the diagnostic performance of point-shear wave elastography (pSWE) and magnetic resonance elastography (MRE) in the hepatic fibrosis diagnostic. A meta-analysis was carried out based on articles published until October 2020. The articles are available at following databases: MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Scientific Electronic Library Online, LILACS, Scopus, and CINAHL. Diagnostic performances were analyzed per METAVIR F2, using 3.5kPa as target fibrosis. Assessment of the methodological quality of the incorporated papers by the QUADAS-2 tool for pSWE and MRE. A total 2,153 studies articles were evaluated and 44 studies, comprising 6,081 patients with individual data, were included in the meta-analysis: 28 studies for pSWE and 16 studies for MRE. The pooled sensitivity and specificity were 0.86 (95%CI 0.80-0.90) and 0.88 (95%CI 0.85-0.91), respectively, for pSWE, compared with 0.94 (95%CI 0.89-0.97) and 0.95 (95%CI 0.89-0.98) respectively, for MRE. The pooled SROC curve for pSWE shows in the area under the curve (AUC) of 0.93 (95%CI 0.90-0.95), whereas the AUC for MRE was 0.98 (95%CI 0.96-0.99). The diagnostic odds ratio for pSWE and MRE were 41 (95%CI 24-72) and 293 (95%CI 86-1000), respectively. There was statistically significant heterogeneity for pSWE sensitivity (I-2 = 85.26, P<0.001) and specificity (I-2 = 89.46, P<0.001). The heterogeneity for MRE also was significant for sensitivity (I-2 = 73.28, P<0.001) and specificity (I-2 = 87.24, P<0.001). Therefore, both pSWE and MRE are suitable modalities for assessing liver fibrosis. In addition, MRE is a more accurate imaging technique than pSWE and can be used as alternative to invasive biopsy.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Shear Wave Elastography for Assessment of Biopsy-Proven Renal Fibrosis: A Systematic Review and Meta-analysis
    Cao, Huiling
    Ke, Ben
    Lin, Feng
    Xue, Yuting
    Fang, Xiangdong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (05): : 1037 - 1048
  • [32] Shear-wave elastography for the evaluation of tendinopathies: a systematic review and meta-analysis
    Albano, Domenico
    Basile, Mariachiara
    Gitto, Salvatore
    Messina, Carmelo
    Longo, Stefano
    Fusco, Stefano
    Snoj, Ziga
    Gianola, Silvia
    Bargeri, Silvia
    Castellini, Greta
    Sconfienza, Luca Maria
    RADIOLOGIA MEDICA, 2024, 129 (01): : 107 - 117
  • [33] Shear-wave elastography for the evaluation of tendinopathies: a systematic review and meta-analysis
    Domenico Albano
    Mariachiara Basile
    Salvatore Gitto
    Carmelo Messina
    Stefano Longo
    Stefano Fusco
    Ziga Snoj
    Silvia Gianola
    Silvia Bargeri
    Greta Castellini
    Luca Maria Sconfienza
    La radiologia medica, 2024, 129 : 107 - 117
  • [34] Shear-wave elastography of the plantar fascia: a systematic review and meta-analysis
    Albano, Domenico
    Messina, Carmelo
    Gitto, Salvatore
    Serpi, Francesca
    Basile, Mariachiara
    Acquasanta, Marzia
    Lanza, Ezio
    Sconfienza, Luca Maria
    JOURNAL OF ULTRASOUND, 2023, 26 (01) : 59 - 64
  • [35] Shear-wave elastography of the plantar fascia: a systematic review and meta-analysis
    Domenico Albano
    Carmelo Messina
    Salvatore Gitto
    Francesca Serpi
    Mariachiara Basile
    Marzia Acquasanta
    Ezio Lanza
    Luca Maria Sconfienza
    Journal of Ultrasound, 2023, 26 : 59 - 64
  • [36] The diagnostic performance of shear wave elastography for malignant cervical lymph nodes: A systematic review and meta-analysis
    Suh, Chong Hyun
    Choi, Young Jun
    Baek, Jung Hwan
    Lee, Jeong Hyun
    EUROPEAN RADIOLOGY, 2017, 27 (01) : 222 - 230
  • [37] The diagnostic performance of shear wave elastography for malignant cervical lymph nodes: A systematic review and meta-analysis
    Chong Hyun Suh
    Young Jun Choi
    Jung Hwan Baek
    Jeong Hyun Lee
    European Radiology, 2017, 27 : 222 - 230
  • [38] Diagnostic performance of shear wave elastography in thyroid nodules with indeterminate cytology: A systematic review and meta-analysis
    Qiu, Yuxuan
    Xing, Zhichao
    Yang, Qianru
    Luo, Yan
    Ma, Buyun
    HELIYON, 2023, 9 (10)
  • [39] Two-dimensional shear wave elastography for significant liver fibrosis in patients with chronic hepatitis B: A systematic review and meta-analysis
    Wei, Hong
    Jiang, Han-Yu
    Li, Mou
    Zhang, Tong
    Song, Bin
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 124
  • [40] Diagnostic Performance of Magnetic Resonance Elastography for the Staging of Liver Fibrosis: A Systematic Review and Collaborative Individual Participant Data Meta-Analysis
    Singh, Siddharth
    Venkatesh, Sudhakar
    Wang, Zhen
    Miller, Frank
    Motosugi, Utaroh
    Low, Russell
    Hassanein, Tarek
    Asbach, Patrick
    Godfrey, Edmund
    Yin, Meng
    Chen, Jun
    Keaveny, Andrew
    Bohte, Anneloes
    Murad, Mohammad
    Talwalkar, Jay
    Ehman, Richard
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 : S144 - S144