Diagnostic accuracy of magnetic resonance elastography and point-shear wave elastography for significant hepatic fibrosis screening: Systematic review and meta-analysis

被引:6
|
作者
Schambeck, Joao Paulo L. [1 ,2 ]
Forte, Gabriele C. [2 ,3 ]
Goncalves, Luana M. [1 ,2 ]
Stuker, Guilherme [2 ]
Kotlinski, Joao Bruno F. [3 ]
Tramontin, Giacomo [2 ]
Altmayer, Stephan [1 ]
Watte, Guilherme [4 ]
Hochhegger, Bruno [1 ,2 ,4 ,5 ]
机构
[1] Pontificia Univ Catolica Rio Grande do Sul, Postgrad Program Med & Hlth Sci, Porto Alegre, RS, Brazil
[2] Pontificia Univ Catolica Rio Grande do Sul, Hosp Sao Lucas, Dept Radiol, Porto Alegre, RS, Brazil
[3] Pontificia Univ Catolica Rio Grande do Sul, Fac Med, Porto Alegre, RS, Brazil
[4] LABIMED, Dept Radiol, Med Imaging Res Lab, Porto Alegre, RS, Brazil
[5] Fed Univ Hlth Sci Porto Alegre, Dept Diagnost Methods, Porto Alegre, RS, Brazil
来源
PLOS ONE | 2023年 / 18卷 / 02期
关键词
RADIATION-FORCE IMPULSE; CHRONIC VIRAL-HEPATITIS; LIVER FIBROSIS; NONINVASIVE ASSESSMENT; TRANSIENT ELASTOGRAPHY; MR ELASTOGRAPHY; ULTRASOUND ELASTOGRAPHY; ARFI; PERFORMANCE; STEATOSIS;
D O I
10.1371/journal.pone.0271572
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The hepatic diseases are extremely common in clinical practice. The correct classification of liver fibrosis is extremely important, as it influences therapy and predicts disease outcomes. The purpose of this study is to compare the diagnostic performance of point-shear wave elastography (pSWE) and magnetic resonance elastography (MRE) in the hepatic fibrosis diagnostic. A meta-analysis was carried out based on articles published until October 2020. The articles are available at following databases: MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Scientific Electronic Library Online, LILACS, Scopus, and CINAHL. Diagnostic performances were analyzed per METAVIR F2, using 3.5kPa as target fibrosis. Assessment of the methodological quality of the incorporated papers by the QUADAS-2 tool for pSWE and MRE. A total 2,153 studies articles were evaluated and 44 studies, comprising 6,081 patients with individual data, were included in the meta-analysis: 28 studies for pSWE and 16 studies for MRE. The pooled sensitivity and specificity were 0.86 (95%CI 0.80-0.90) and 0.88 (95%CI 0.85-0.91), respectively, for pSWE, compared with 0.94 (95%CI 0.89-0.97) and 0.95 (95%CI 0.89-0.98) respectively, for MRE. The pooled SROC curve for pSWE shows in the area under the curve (AUC) of 0.93 (95%CI 0.90-0.95), whereas the AUC for MRE was 0.98 (95%CI 0.96-0.99). The diagnostic odds ratio for pSWE and MRE were 41 (95%CI 24-72) and 293 (95%CI 86-1000), respectively. There was statistically significant heterogeneity for pSWE sensitivity (I-2 = 85.26, P<0.001) and specificity (I-2 = 89.46, P<0.001). The heterogeneity for MRE also was significant for sensitivity (I-2 = 73.28, P<0.001) and specificity (I-2 = 87.24, P<0.001). Therefore, both pSWE and MRE are suitable modalities for assessing liver fibrosis. In addition, MRE is a more accurate imaging technique than pSWE and can be used as alternative to invasive biopsy.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Comparison of magnetic resonance elastography and transient elastography in the diagnosis of hepatic fibrosis: a systematic review and meta-analysis
    Bi, Junying
    Liu, Liangjin
    Qin, Tao
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (08) : 8692 - 8700
  • [2] Diagnostic accuracy of point shear wave elastography and transient elastography for staging hepatic fibrosis in patients with non-alcoholic fatty liver disease: a meta-analysis
    Jiang, Weixi
    Huang, Sirun
    Teng, Hua
    Wang, Peipei
    Wu, Meng
    Zhou, Xia
    Ran, Haitao
    BMJ OPEN, 2018, 8 (08):
  • [3] Diagnostic Accuracy of Transient Elastography and Two-Dimensional Shear Wave Elastography for Staging Liver Fibrosis in Children or Adolescents: A Systematic Review and Meta-Analysis
    Gong, Xiuru
    Zhu, Tingting
    Peng, Xiaolin
    Xing, Dongwei
    Zhang, Minguang
    CURRENT MEDICAL IMAGING, 2023, 19 (11) : 1258 - 1272
  • [4] Shear wave elastography: a systematic review and meta-analysis
    Mo, Jin A.
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2016, 59 (07): : 529 - 535
  • [5] Diagnostic accuracy of elastography and magnetic resonance imaging in patients with NAFLD: A systematic review and meta-analysis
    Selvaraj, Emmanuel Anandraj
    Mozes, Ferenc Emil
    Jayaswal, Arjun Narayan Ajmer
    Zafarmand, Mohammad Hadi
    Vali, Yasaman
    Lee, Jenny A.
    Levick, Christina Kim
    Young, Liam Arnold Joseph
    Palaniyappan, Naaventhan
    Liu, Chang-Hai
    Aithal, Guruprasad Padur
    Romero-Gomez, Manuel
    Brosnan, M. Julia
    Tuthill, Theresa A.
    Anstee, Quentin M.
    Neubauer, Stefan
    Harrison, Stephen A.
    Bossuyt, Patrick M.
    Pavlides, Michael
    JOURNAL OF HEPATOLOGY, 2021, 75 (04) : 770 - 785
  • [6] Diagnostic value of magnetic resonance elastography for detecting and staging of hepatic fibrosis: A meta-analysis
    Su, L. -N.
    Guo, S. -L.
    Li, B. -X.
    Yang, P.
    CLINICAL RADIOLOGY, 2014, 69 (12) : E545 - E552
  • [7] Comparing the accuracy of shear wave elastography and strain elastography in the diagnosis of breast tumors A systematic review and meta-analysis
    Wu, Huayu
    Wang, Cong
    An, Qi
    Qu, Xiaomeng
    Wu, Xiaohang
    Yan, Yumei
    MEDICINE, 2022, 101 (44) : E31526
  • [8] Accuracy of real-time shear wave elastography in staging hepatic fibrosis: a meta-analysis
    Fu, Juan
    Wu, Biao
    Wu, Huazhi
    Lin, Feng
    Deng, Wei
    BMC MEDICAL IMAGING, 2020, 20 (01)
  • [9] Accuracy of real-time shear wave elastography in staging hepatic fibrosis: a meta-analysis
    Juan Fu
    Biao Wu
    Huazhi Wu
    Feng Lin
    Wei Deng
    BMC Medical Imaging, 20
  • [10] Diagnostic accuracy of shear wave elastography for endometrial cancer: A meta-analysis
    Bian, Jinyi
    Li, Jingnan
    Liu, Yangcheng
    MEDICINE, 2023, 102 (04) : E32700