Experimental research on fire performance of U-shaped steel-concrete composite beam under uniformly distributed loading

被引:7
|
作者
Yang, Weiqi [1 ,2 ]
Yang, Yuanlong [1 ,2 ]
Wang, Guojun [1 ,2 ]
Liu, Faqi [3 ]
Chen, Yohchia Frank [4 ]
机构
[1] Chongqing Univ, Key Lab New Technol Construct Cities Mt Area, Minist Educ, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[3] Harbin Inst Technol Harbin, Sch Civil Engn, Harbin 150090, Heilongjiang Pr, Peoples R China
[4] Penn State Univ, Dept Civil Engn, Middletown, PA 17057 USA
关键词
U-shaped steel-concrete composite beam; (USCB); Fire protection layer; Fire test; Fire resistance; Channel steel connector; CHANNEL SHEAR CONNECTORS; BEHAVIOR;
D O I
10.1016/j.tws.2023.110700
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Four U-shaped steel-concrete composite beams with channel connectors (CUSCBs) were designed and tested under the uniformly distributed vertical load and ISO-834 standard fire condition. The sectional temperature distribution, mid-span deformation development, fire resistance, and failure modes of each CUSCB under fire were investigated. The test results reveal the following facts: (1) All specimens fail flexurally; (2) The interface between the concrete flange and the U-shaped steel web remain intact and no local buckling occurs in U-shaped steel; (3) The concrete temperature decreases from the fired surface to the non-fired surface gradually; and (4) The temperature of the concrete at the corner between the lower flange and the web of U-shaped steel is higher than the concrete within the beam. Moreover, the fire resistance increases with the increase of fire protection layer thickness; and the bottom reinforcement in U-shaped steel can improve the fire resistance. The fire behavior of CUSCBs was also analyzed using the finite element program ABAQUS and the simulated temperature distributions and fire resistances were found to be in good agreement with the test results. Furthermore, the parametric analysis results show that the thickness of fire protection layer, the diameter of bottom reinforcement, the load ratio, and the thickness of U-shaped steel have significant impact on the fire resistance, while the section size and material strength have little impact. Lastly, design suggestions for the fire resistance design of CUSCBs are proposed.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Experimental study on mechanical performance of steel-concrete girders under fire loading
    Yao W.-F.
    Huang Q.
    Zhang J.-X.
    Yao, Wei-Fa (ywfzjx@163.com), 1600, Tsinghua University (33): : 58 - 65
  • [22] Experimental investigation on the flexural behavior of steel-concrete composite beams with U-shaped steel girders and angle connectors
    Liu, Yong
    Guo, Lanhui
    Qu, Bing
    Zhang, Sumei
    ENGINEERING STRUCTURES, 2017, 131 : 492 - 502
  • [23] Experimental and numerical investigations on square CFST column to U-shaped steel-concrete composite beam joints with internal T-shaped diaphragms
    Xu, Xing
    Cheng, Rui
    Yang, Pu
    Yu, Yuanlin
    JOURNAL OF BUILDING ENGINEERING, 2022, 60
  • [24] Experimental study on internal force variation of steel-concrete composite beam under fire
    Zhang J.-C.
    Zhang D.-S.
    Dong Y.-L.
    Wang W.-H.
    Gongcheng Lixue/Engineering Mechanics, 2019, 36 (06): : 183 - 192and210
  • [25] Seismic performance and design method of T-shaped CFST column to U-shaped steel-concrete composite beam joint with vertical stiffeners
    Cheng, Yu
    Yang, Yuanlong
    Liu, Jiepeng
    Nie, Wanqian
    Chen, Yohchia Frank
    ENGINEERING STRUCTURES, 2023, 275
  • [26] Experimental Investigation on Flexural Behavior of U-Shaped Steel-Concrete Composite Beams with Bolt Connections under a Negative Bending Moment
    Kim, Chul-Goo
    Kim, Hyoung-Seop
    Lee, Sang-Hyun
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (07)
  • [27] Behaviour of a joint between a U-shaped steel-concrete beam and a concrete-filled steel tubular column
    Heng, Piseth
    Lepourry, Clemence
    Somja, Hugues
    Palas, Franck
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 175
  • [28] Fire performance research and application on steel-concrete composite structures
    Yu, Zhiwu
    Ding, Faxing
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2010, 31 (06): : 96 - 109
  • [29] Experimental Study on Mechanical Performance of U-Shaped Steel-Encased Concrete Composite Beam-Girder Joints
    Hu, Zhangqi
    He, Ran
    Wang, Yukui
    Lv, Weirong
    Li, Jingchao
    ADVANCES IN CIVIL ENGINEERING, 2021, 2021
  • [30] Structural Behavior of a Steel-Concrete Composite Beam under Fire Condition
    Kang, M. S.
    Pak, H.
    Kang, J. W.
    Kee, S. H.
    Choi, B. J.
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 2146 - 2153