Electrolyte Additives and 3D X-ray Tomography Study of All Iron Redox Flow Batteries in a Full-Cell Configuration for High Capacity Retention

被引:2
|
作者
Furquan, Mohammad [1 ]
Ali, Saad [2 ]
Hussaini, Syed Rizwanullah [3 ]
Bhat, Zahid Manzoor [1 ]
Sial, Muhammad Aurang Zeb Gul [1 ]
Alzahrani, Atif Saeed [2 ,4 ]
Yamani, Zain H. [1 ]
Qamar, Mohammad [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Hydrogen Technol & Carbo, Dhahran 31261, Saudi Arabia
[2] King Fahd Univ Petr & Minerals, Dept Mat Sci & Engn, Dhahran 31261, Saudi Arabia
[3] King Fahd Univ Petr & Minerals, Coll Petr Engn & Geosci, Dhahran 31261, Saudi Arabia
[4] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Sustainable Energy Syst, Dhahran 31261, Saudi Arabia
关键词
PERFORMANCE; ENERGY; EFFICIENCY; DENSITY; STORAGE;
D O I
10.1021/acs.energyfuels.3c04842
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
All-iron redox flow batteries (Fe-RFBs) can be the grid's most cost-effective and environmentally friendly electrochemical energy storage solution. However, low-capacity retention due to electrolyte degradation is the major hurdle in its progress. This study examines the effects of different electrolyte additives and their effects on the Fe-RFBs system in a full-cell configuration. Adding hydrochloric acid (HCl) results in a slow aging of the iron chloride electrolyte compared to that without HCl, leading to improved electrochemical performance. This improvement is evident in terms of both capacity retention and Coulombic efficiency (CE). HCl (0.2 M) addition in the electrolyte results in a discharge capacity retention of around 98% compared with 73% without HCl after 150 cycles. Moreover, the plating patterns of Fe at the negative electrode are also greatly affected due to HCl. Ex situ 3D X-ray tomography of Fe-plated electrodes in the presence and absence of HCl in an all-iron chloride electrolyte within the full-cell system is conducted, and the iron deposition pattern on the electrodes is obtained by FE-SEM. This study reveals the critical role of additives in the reversibility of iron deposition and stripping and its overall effect on cycling life to all iron redox flow batteries.
引用
收藏
页码:4699 / 4710
页数:12
相关论文
共 50 条
  • [21] PRECISE 3D DIMENSIONAL METROLOGY USING HIGH RESOLUTION X-RAY COMPUTED TOMOGRAPHY (μCT)
    Brunke, Oliver
    Santillan, Javier
    Suppes, Alexander
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [23] Laboratory-based x-ray computed tomography for 3D imaging of samples in a diamond anvil cell in situ at high pressures
    Ohta, Kenji
    Wakamatsu, Tatsuya
    Kodama, Manabu
    Kawamura, Katsuyuki
    Hirai, Shuichiro
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (09):
  • [24] X-Ray-Computed Radiography and Tomography Study of Electrolyte Invasion and Distribution inside Pristine and Heat-Treated Carbon Felts for Redox Flow Batteries
    Gebhard, Marcus
    Schnucklake, Maike
    Hilger, Andre
    Roehe, Maximilian
    Osenberg, Markus
    Krewer, Ulrike
    Manke, Ingo
    Roth, Christina
    ENERGY TECHNOLOGY, 2020, 8 (03)
  • [25] Comparative Study of 2D Petrographic and 3D X-ray Tomography Investigations of Air Voids in Asphalt
    Middendorf, Moritz
    Umbach, Cristin
    Boehm, Stefan
    Liu, Jia
    Middendorf, Bernhard
    MATERIALS, 2023, 16 (03)
  • [26] 2D automated SEM and 3D X-ray computed tomography study on inclusion analysis of steels
    Bandi, Bharath
    Santillana, Begona
    Tiekink, Wouter
    Koura, Nadia
    Williams, Mark
    Srirangam, Prakash
    IRONMAKING & STEELMAKING, 2020, 47 (01) : 47 - 50
  • [27] 3D morphological analysis of copper foams as current collectors for Li-ion batteries by means of X-ray tomography
    Etiemble, A.
    Adrien, J.
    Maire, E.
    Idrissi, H.
    Reyter, D.
    Roue, L.
    MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2014, 187 : 1 - 8
  • [28] High-resolution 3D phenotyping of the grapevine root system using X-ray Computed Tomography
    Schmitz, R.
    Atkinson, B. S.
    Sturrock, C. J.
    Hausmann, L.
    Toepfer, R.
    Herzog, K.
    VITIS, 2021, 60 (01) : 21 - 27
  • [29] Middle and Inner Ear 3D Reconstructions using High Resolution X-ray Micro-Tomography
    Labrousse, Marc
    Dubernard, Xavier
    Settembre, Nicla
    Tonnelet, Romain
    Avisse, Claude
    Devy, Jerome
    Renard, Yohann
    FASEB JOURNAL, 2016, 30
  • [30] Investigation of the melt and flow behavior in the hot-end of a 3D printer using X-ray computed tomography
    Chung, Phi-Long
    Kattinger, Julian
    Kornely, Mike
    Ehrler, Julian
    Bonten, Christian
    Kreutzbruck, Marc
    e-Journal of Nondestructive Testing, 2024, 29 (Special Issue):