Smart wound dressing for advanced wound management: Real-time monitoring and on-demand treatment

被引:52
|
作者
Pang, Qian [1 ]
Yang, Fang [1 ]
Jiang, Zilian [1 ]
Wu, Kaihao [1 ]
Hou, Ruixia [1 ]
Zhu, Yabin [1 ]
机构
[1] Ningbo Univ, Hlth Sci Ctr, Dept Cell Biol & Regenerat Med, Ningbo 315211, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Biomarkers; Wearable sensors; Drug delivery; Wound dressing; Wound management; HYPOXIA-INDUCIBLE FACTOR; WIRELESS CONNECTIVITY; CONDUCTIVE HYDROGELS; TREATING WOUNDS; IN-VITRO; SKIN; TEMPERATURE; INFECTION; SENSORS; PH;
D O I
10.1016/j.matdes.2023.111917
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Timely and accurate assessment of wounds during the wound healing process is key for correct diagnosis and treatment decisions for wound repair. However, traditional wound management strategies often fail to provide timely and accurate information on wound status, thereby delaying or misleading treatments. Smart wound dressings that enable the in situ real-time monitoring of wound-related biomarkers, early diagnosis and on-demand treatment of adverse wound healing events, such as bacterial infection and inflammation, by integrating wearable sensors, advanced drug delivery systems and wireless communi-cation technology have recently been developed and could improve wound management. In this review, we provided an overview of biomarkers, including temperature, pH, uric acid, glucose, reactive oxygen (ROS), oxygen and enzymes, related to adverse wound healing events and exiting sensors for detecting these biomarkers based on colorimetric, fluorimetric and electrochemical approaches. Examples of smart wound dressings that integrate controllable drug delivery functions triggered by both endogenous and exogenous stimuli, the all-in-one wound dressing systems capable of real-time monitoring and on-demand treatment, and the major challenges and exciting opportunities of such smart wound dressings in wound management are presented and comprehensively discussed. & COPY; 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Real-Time Monitoring of Wound States via Rationally Engineered Biosensors
    Zeng, Qiankun
    Shi, Guoyue
    Zhang, Min
    ADVANCED SENSOR RESEARCH, 2024, 3 (03):
  • [32] A glucose responsive multifunctional hydrogel with antibacterial properties and real-time monitoring for diabetic wound treatment
    Yang, Zhifei
    Zhang, Jiaxu
    Wang, Chen
    Yu, Fangzheng
    Yu, Wen
    Zhao, Zheng
    BIOMATERIALS SCIENCE, 2024, 13 (01) : 275 - 286
  • [33] On-demand removable hydrogels based on photolabile cross-linkings as wound dressing materials
    Wu, Haiyang
    Qin, Zezhao
    Yu, Xiaofeng
    Li, Jinge
    Lv, Hongying
    Yang, Xiaoniu
    JOURNAL OF MATERIALS CHEMISTRY B, 2019, 7 (37) : 5669 - 5676
  • [34] Wireless and Closed-Loop Smart Dressing for Exudate Management and On-Demand Treatment of Chronic Wounds
    Ge, Zhenyou
    Guo, Wenshang
    Tao, Ye
    Sun, Haoxiu
    Meng, Xiangyu
    Cao, Liangyu
    Zhang, Shanguo
    Liu, Weiyu
    Akhtar, Muhammad Luqman
    Li, Yu
    Ren, Yukun
    ADVANCED MATERIALS, 2023, 35 (47)
  • [35] κ-carrageenan-C-phycocyanin based smart injectable hydrogels for accelerated wound recovery and real-time monitoring
    Dev, Atul
    Mohanbhai, Soni Jignesh
    Kushwaha, Avinash Chandra
    Sood, Ankur
    Sardoiwala, Mohammed Nadim
    Choudhury, Subhasree Roy
    Karmakar, Surajit
    Acta Biomaterialia, 2020, 109 : 121 - 131
  • [36] κ-carrageenan-C-phycocyanin based smart injectable hydrogels for accelerated wound recovery and real-time monitoring
    Dev, Atul
    Mohanbhai, Soni Jignesh
    Kushwaha, Avinash Chandra
    Sood, Ankur
    Sardoiwala, Mohammed Nadim
    Choudhury, Subhasree Roy
    Karmakar, Surajit
    ACTA BIOMATERIALIA, 2020, 109 : 121 - 131
  • [37] A Biomimetic Asymmetric Structured Intelligent Wound Dressing with Dual-modality Humidity-pressure Sensing for Non-invasive and Real-time Wound Healing Monitoring
    Ding, Shanshan
    Jin, Xu
    Guo, Jia
    Kou, Buxin
    Chai, Mengyin
    Dou, Shuang
    Jin, Gaoling
    Zhang, Huijie
    Zhao, Ximeng
    Ma, Jiayu
    Li, Xiuyan
    Liu, Xiaoni
    Wang, Bin
    Zhang, Xiuqin
    ADVANCED FIBER MATERIALS, 2025, 7 (01) : 156 - 171
  • [38] An ionic liquid-functionalized near-infrared fluorescent hydrogel dressing for promoting wound healing and real-time monitoring hypochlorous acid at the diabetic wound site
    Zong, Yuange
    Liu, Pan
    Zha, Ruyan
    Zong, Beige
    Wang, Yanying
    Fang, Huaifang
    Wong, Wing-Leung
    Li, Chunya
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 394
  • [39] An On-Demand ELT Architecture for Real-Time BI
    Freudenreich, Tobias
    Furtado, Pedro
    Koncilia, Christian
    Thiele, Maik
    Waas, Florian
    Wrembel, Robert
    ENABLING REAL-TIME BUSINESS INTELLIGENCE, VLDB 2012, 2013, 154 : 50 - 59
  • [40] Real-time wound management through integrated pH sensors: a review
    Khan, Munezza Ata
    Ansari, Umar
    Ali, Murtaza Najabat
    SENSOR REVIEW, 2015, 35 (02) : 183 - 189