Simulation and experimental study on ECT of circumferential cracks in small-diameter tubes

被引:0
|
作者
Yin, Zun [1 ]
Li, Jiaojiao [1 ]
Meng, Yongle [1 ]
Qin, Jianzhu [2 ]
Tang, Dianwu [2 ]
Hou, Zhaotang [1 ]
Li, Zhaoyang [3 ]
机构
[1] Xian Thermal Power Res Inst, Xian 710032, Peoples R China
[2] Dongfang Power Plant Huaneng Hainan Power Generat, Dongfang 562700, Peoples R China
[3] Nanchang Hangkong Univ, Key Lab Nondestruct Testing, Minist Educ, Nanchang 330063, Peoples R China
基金
中国国家自然科学基金;
关键词
EDDY-CURRENT PROBE; DEFECTS;
D O I
10.1063/5.0131357
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Circumferential crack detection of small diameter tubes is a difficult problem to solve in eddy current testing. The three-dimensional simulation model is established through electromagnetic field simulation software to analyze the eddy current field distribution of the traditional bobbin probe and transverse cylindrical probe in small diameter tubes. The results show that the circumferential crack has a more marked disturbance to the eddy current field generated by the latter. Based on the simulation research, a new type of probe based on transverse excitation is designed to detect the artificial circumferential crack of the specimen with the designed probe, which can effectively detect the circumferential crack and has a potentially high sensitivity to the narrower natural circumferential crack.
引用
收藏
页数:7
相关论文
共 50 条
  • [22] R134a flow patterns in small-diameter tubes
    Chen, L
    Tian, YS
    Karayiannis, TG
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2005, 219 (E2) : 167 - 181
  • [23] Investigation of a method for small-diameter hot rolled tubes production
    Romantsev, B.A.
    Shamanaev, V.I.
    Vysokosov, A.G.
    Umerenkov, V.N.
    Karmazin, V.Ya.
    Stal', 1991, (11): : 53 - 55
  • [24] Inactivation of Escherichia coli in Small-Diameter Tubes by Remote Plasmas
    Asada R.
    Fujiyama T.
    Bounyang O.
    Sakamoto J.J.
    Matsuura H.
    Tsuchido T.
    Furuta M.
    Plasma Medicine, 2022, 12 (03) : 59 - 68
  • [25] ULTRASONIC INSPECTION TECHNIQUE FOR FILLET WELDS IN SMALL-DIAMETER TUBES
    KRAKOVYAK, MF
    RAKHMANOV, VV
    GREBENNIK, IL
    WELDING PRODUCTION, 1971, 18 (09): : 61 - +
  • [26] EXPERIMENTAL STUDIES OF SMALL-DIAMETER ARTERIAL PROSTHESES
    BARROSDSA, AAB
    SAUVAGE, LR
    WALKER, MW
    BERGER, K
    ROBEL, SB
    YATES, SG
    BRITISH JOURNAL OF SURGERY, 1979, 66 (05) : 364 - 365
  • [27] Experimental recharge by small-diameter wells: the Pirna, Saxony, case study
    Handel, Falk
    Binder, Martin
    Dietze, Michael
    Liedl, Rudolf
    Dietrich, Peter
    ENVIRONMENTAL EARTH SCIENCES, 2016, 75 (10)
  • [28] Experimental recharge by small-diameter wells: the Pirna, Saxony, case study
    Falk Händel
    Martin Binder
    Michael Dietze
    Rudolf Liedl
    Peter Dietrich
    Environmental Earth Sciences, 2016, 75
  • [29] STUDY OF IMPEDANCE OF THE WEAK-CURRENT GLOW-DISCHARGE IN SMALL-DIAMETER TUBES
    PRIVALOV, VE
    SHISHOV, SI
    ZHURNAL TEKHNICHESKOI FIZIKI, 1989, 59 (07): : 204 - 208
  • [30] STUDY ON SMALL-DIAMETER DRILLING IN GFRP
    AOYAMA, E
    INOUE, H
    HIROGAKI, T
    NOBE, H
    KITAHARA, Y
    KATAYAMA, T
    COMPOSITE STRUCTURES, 1995, 32 (1-4) : 567 - 573