Simulation and experimental study on ECT of circumferential cracks in small-diameter tubes

被引:0
|
作者
Yin, Zun [1 ]
Li, Jiaojiao [1 ]
Meng, Yongle [1 ]
Qin, Jianzhu [2 ]
Tang, Dianwu [2 ]
Hou, Zhaotang [1 ]
Li, Zhaoyang [3 ]
机构
[1] Xian Thermal Power Res Inst, Xian 710032, Peoples R China
[2] Dongfang Power Plant Huaneng Hainan Power Generat, Dongfang 562700, Peoples R China
[3] Nanchang Hangkong Univ, Key Lab Nondestruct Testing, Minist Educ, Nanchang 330063, Peoples R China
基金
中国国家自然科学基金;
关键词
EDDY-CURRENT PROBE; DEFECTS;
D O I
10.1063/5.0131357
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Circumferential crack detection of small diameter tubes is a difficult problem to solve in eddy current testing. The three-dimensional simulation model is established through electromagnetic field simulation software to analyze the eddy current field distribution of the traditional bobbin probe and transverse cylindrical probe in small diameter tubes. The results show that the circumferential crack has a more marked disturbance to the eddy current field generated by the latter. Based on the simulation research, a new type of probe based on transverse excitation is designed to detect the artificial circumferential crack of the specimen with the designed probe, which can effectively detect the circumferential crack and has a potentially high sensitivity to the narrower natural circumferential crack.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Guided waves based diagnostic imaging of circumferential cracks in small-diameter pipe
    Liu, Kehai
    Wu, Zhanjun
    Jiang, Youqiang
    Wang, Yishou
    Zhou, Kai
    Chen, Yingpu
    ULTRASONICS, 2016, 65 : 34 - 42
  • [2] STRENGTH OF SMALL-DIAMETER ELECTRICALLY WELDED TUBES
    MONOSHKO.AM
    SVETLAKO.VA
    GAZMAN, SM
    GRINBERG, ZA
    PYKHOV, SI
    WELDING PRODUCTION, 1971, 18 (11): : 34 - &
  • [3] STRAIGHTENING SMALL-DIAMETER TUBES ON DRUM EQUIPMENT
    SEMENENKO, YL
    VARAVA, LM
    STEEL IN THE USSR, 1975, 5 (01): : 60 - 61
  • [4] Coke from small-diameter tubes analyzed
    Albright, Lyle F.
    1600, (86):
  • [5] A Novel Circumferential Eccentric Eddy Current Probe and Its Application in Defect Detection of Small-Diameter Tubes
    Yang Q.
    Xie S.
    He K.
    Wang K.
    Tong Z.
    Chen H.
    Chen Z.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2021, 57 (12): : 109 - 117
  • [6] A novel circumferential eccentric eddy current probe and its application for defect detection of small-diameter tubes
    Yang, Qingning
    Xie, Shejuan
    He, Kun
    Chen, Yue-E
    Chen, Zhenmao
    Uchimoto, Tetsuya
    Takagi, Toshiyuki
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 331
  • [7] AN EXPERIMENTAL-STUDY OF EVAPORATING SMALL-DIAMETER JETS
    KOWALEWSKI, TA
    HILLER, WJ
    BEHNIA, M
    PHYSICS OF FLUIDS A-FLUID DYNAMICS, 1993, 5 (08): : 1883 - 1890
  • [8] Experimental Study on Strain Sensing by Small-Diameter FBG
    Liu, Rong-mei
    Li, Qiufeng
    Zhu, Lujia
    Liang, Dakai
    SECOND INTERNATIONAL SEMINAR ON PHOTONICS, OPTICS, AND ITS APPLICATIONS (ISPHOA 2016), 2016, 10150
  • [9] AUTOMATIC SUBMERGED ARC WELDING OF SMALL-DIAMETER CIRCUMFERENTIAL SEAMS
    CHERNENK.YA
    WELDING PRODUCTION, 1970, 17 (02): : 67 - &
  • [10] Safety of Small-Diameter Endotracheal Tubes in Microlaryngeal Surgery
    Strober, William A.
    Enin, Kwasi
    Kallogjeri, Dorina
    Piccirillo, Jay F.
    Komen, Helga
    Rohlfing, Matthew L.
    LARYNGOSCOPE, 2025, 135 (04): : 1451 - 1454