Meta-analysis of Comparative Studies Between Self- and Balloon-Expandable Bridging Stent Grafts in Branched Endovascular Aneurysm Repair

被引:16
|
作者
Nana, Petroula [1 ,2 ]
Spanos, Konstantinos [1 ,2 ]
Brodis, Alexandros [3 ]
Panuccio, Giuseppe [2 ]
Kouvelos, George [1 ]
Behrendt, Christian-Alexander [2 ]
Giannoukas, Athanasios [1 ]
Koelbel, Tilo [2 ]
机构
[1] Univ Thessaly, Gen Univ Hosp Larissa, Sch Hlth Sci, Vasc Surg Dept, Larisa, Greece
[2] Univ Heart & Vasc Ctr, German Aort Ctr Hamburg, Dept Vasc Med, Hamburg, Germany
[3] Gen Univ Hosp Larissa, Neurosurg Dept, Larisa, Greece
关键词
balloon-expandable; self-expanding; stent; branched device; complex aortic repair; outcomes; OFF-THE-SHELF; T-BRANCH; EARLY OUTCOMES; EXPERIENCE;
D O I
10.1177/15266028221083458
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Currently there is no robust evidence which type of bridging stent graft provides better outcomes after branched endovascular aortic repair (BEVAR). Self-expanding (SESG) and balloon-expandable (BESG) stent grafts are both commonly used to connect branches to their respective target vessels (TV). The aim of the current review was to evaluate the impact of the type of bridging stent grafts on TV outcomes during the mid-term follow-up after BEVAR. Materials and Methods: The study protocol was registered to the PROSPERO (CRD42021274766). A search of the English literature was conducted, using PubMed and EMBASE databases via Ovid and Cochrane database via CENTRAL, from inception to June 30, 2021, using the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines. Only comparative studies on BEVAR reporting TV outcomes related to BESG vs SESG were considered eligible. Individual studies were assessed for risk of bias using the Newcastle Ottawa Scale. The Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach was used to evaluate the quality of evidence. The primary outcomes were primary patency, freedom from endoleak, TV instability, and re-intervention between BESG and SESG, used as bridging stents in branches. The outcomes were summarized as odds ratio along with their 95% confidence intervals (CI), through a paired meta-analysis. Results: Five out of 609 articles published from 2016 to 2020 were included in the analysis. In total, 1406 TV were revascularized, 547 (38.9 %) with BESGs and 859 with SESGs. The overall pooled primary patency (odds ratio [OR], 0.40; 95% confidence interval [CI], 0.29-1.09; p=.256, I-2=4.24%) and freedom from branch-related endoleak (OR, 0.65; 95% CI, 0.17-1.48; p<.122, I-2=0.18%) did not differ between the stent types during the available follow-up (17 months, range = 12-35 months). In 4 studies (619 TV), SESG required fewer secondary interventions (OR, 1.04; 95% CI, 0.23-1.83; p=.009, I-2=0%) and TV instability rate was lower (OR, 0.99; 95% CI, 0.33-1.65; p=.003, I-2=0%) compared with BESG during the available follow-up. Conclusion: BESG and SESG seem to perform similarly in terms of primary patency and branch-related endoleak during the mid-term follow-up. Current data from retrospective studies suggest that overall TV instability and re-intervention rates are favorable for SESG as bridging stent grafts in BEVAR.
引用
收藏
页码:336 / 346
页数:11
相关论文
共 50 条
  • [21] Performance of the Gore VBX Balloon Expandable Endoprosthesis as Bridging Stent-Graft in Branched Endovascular Aortic Repair for Thoracoabdominal Aneurysms
    Torsello, Giovanni B.
    Pitoulias, Apostolos
    Litterscheid, Sarah
    Berekoven, Barbel
    Torsello, Giovanni-Federico
    Austermann, Martin
    Bosiers, Michel J.
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (04) : 549 - 554
  • [22] Aortic neck enlargement after endovascular aneurysm repair using balloon-expandable versus self-expanding endografts
    Savlovskis, Janis
    Krievins, Dainis
    de Vries, Jean-Paul P. M.
    Holden, Andrew
    Kisis, Kaspars
    Gedins, Marcis
    Ezite, Natalija
    Zarins, Christopher K.
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (03) : 541 - 549
  • [23] Meta-Analysis of Comparison Between Self-Expandable and Balloon-Expandable Valves for Patients Having Transcatheter Aortic Valve Implantation
    Moretti, Claudio
    D'Ascenzo, Fabrizio
    Mennuni, Marco
    Taha, Salma
    Brambilla, Nedy
    Nijhoff, Freek
    Fraccaro, Chiara
    Barbanti, Marco
    Tamburino, Corrado
    Tarantini, Giuseppe
    Rossi, Marco L.
    Presbitero, Patrizia
    Napodanno, Massimo
    Stella, Pieter
    Bedogni, Francesco
    Omede, Pierluigi
    Conrotto, Federico
    Montefusco, Antonio
    Giordana, Francesca
    Zoccai, Giuseppe Biondi
    Agostoni, Piefrancesco
    D'Amico, Maurizio
    Rinaldi, Mauro
    Marra, Sebastiano
    Gaita, Fiorenzo
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (12): : 1720 - 1725
  • [24] Aortic valve replacement vs balloon-expandable and self-expandable transcatheter implantation: a network meta-analysis
    Bruno, Francesco
    D'Ascenzo, Fabrizio
    Baldetti, Luca
    Franchin, Luca
    Marengo, Giorgio
    Beviario, Susanna
    Melillo, Francesco
    Gallone, Guglielmo
    De Filippo, Ovidio
    La Torre, Michele
    Rinaldi, Mauro
    Omede, Pierluigi
    Conrotto, Federico
    Salizzoni, Stefano
    Giustetto, Carla
    De Ferrari, Gaetano Maria
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0N) : N54 - N54
  • [25] AORTIC VALVE REPLACEMENT VS BALLOON-EXPANDABLE AND SELF-EXPANDABLE TRANSCATHETER IMPLANTATION: A NETWORK META-ANALYSIS
    Bruno, Francesco
    D'Ascenzo, Fabrizio
    Baldetti, Luca
    Franchin, Luca
    Marengo, Giorgio
    Breviario, Susanna
    Melillo, Francesco
    Gallone, Guglielmo
    De Filippo, Ovidio
    La Torre, Michele
    Rinaldi, Mauro
    Omede, Pierluigi
    Conrotto, Federico
    Salizzoni, Stefano
    De Ferrari, Gaetano
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 1157 - 1157
  • [26] Geometrical Analysis on Flared Section of Stainless-Steel Bridging Stent Grafts for Fenestrated Endovascular Aneurysm Repair
    Colacchio, Elda Chiara
    Squizzato, Francesco
    Marenghi, Marco
    Dall'Antonia, Alberto
    Battocchio, Piero
    Zavatta, Marco
    Piazza, Michele
    Grego, Franco
    Antonello, Michele
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (06) : E74 - E75
  • [27] Endovascular treatment of aortic coarctation using covered balloon-expandable stents-a systematic review and meta-analysis
    He, Fei
    Cao, Zhongze
    Wang, Chen
    Premaratne, Shyamal
    Starnes, Benjamin W.
    Shu, Chang
    Zhang, Wayne W.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [29] Aortic valve replacement vs. balloon-expandable and self-expandable transcatheter implantation: A network meta-analysis
    D'Ascenzo, Fabrizio
    Bruno, Francesco
    Baldetti, Luca
    De Filippo, Ovidio
    Marengo, Giorgio
    Breviario, Susanna
    Melillo, Francesco
    Thyregod, Hans Gustav Horsted
    Thiele, Holger
    Sondergaard, Lars
    Popma, Jeffrey J.
    Kodali, Susheel
    Franchin, Luca
    Annaratone, Margherita
    Marruncheddu, Laura
    Gallone, Guglielmo
    Crimi, Gabriele
    La Torre, Michele
    Rinaldi, Mauro
    Omede, Pierluigi
    Conrotto, Federico
    Salizzoni, Stefano
    De Ferrari, Gaetano Maria
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 337 : 90 - 98
  • [30] Effect of branch length and tortuosity on the outcomes of branched endovascular repair of thoracoabdominal aneurysms using self-expandable bridging stent graft
    Piazza, Michele
    Squizzato, Francesco
    Xodo, Andrea
    Gubert, Alberto
    Grego, Franco
    Antonello, Michele