Hardware implementation of interconnection and damping assignment passivity-based control for BLDC motor using microcontroller

被引:0
|
作者
Astik, Mitesh B. [1 ]
Shah, Dhruv B. [2 ]
Bhatt, Praghnesh [3 ]
Bhalja, Bhavesh R. [4 ]
Modha, Paresh R. [5 ]
机构
[1] AD Patel Inst Technol, Dept Elect Engn, Anand, Gujarat, India
[2] Dynam Res Consultancy, Vadodara, India
[3] Pandit Deendayal Energy Univ, Sch Technol, Dept Elect Engn, Gandhinagar, India
[4] Indian Inst Technol Roorkee, Dept Elect Engn, Roorkee, Uttar Pradesh, India
[5] CVM Univ, Anand, Gujarat, India
关键词
Brushless direct current (BLDC); Immersion and invariance (I&I); Interconnection and damping assignment (IDA); Passivity-based control (PBC); Start-up method; Electrical machine; Permanent magnet machine; SENSORLESS CONTROL; SPEED CONTROLLER; ADAPTIVE-CONTROL; POSITION; TORQUE; STABILIZATION; INVARIANCE; IMMERSION; ALGORITHM; DRIVES;
D O I
10.1108/COMPEL-10-2021-0367
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Purpose The purpose of this paper is to develop a generalized observer and controller for brushless direct current (BLDC) motor to make the system more robust for parameter variations, load torque and speed tracking. Design/methodology/approach A robust interconnection and damping assignment passivity-based control (IDA-PBC) technique for BLDC motor is introduced in this paper. The IDA-PBC is used to obtain the reference voltages for pulse width modulation (PWM) control. The immersion and invariance (I&I) observer is used to estimate the load torque and speed of the BLDC motor. At the time of starting, the motor rotates in arbitrary direction, and sometimes, because of the cogging action, it may take a huge current. Therefore, a new start-up method is proposed for the BLDC motor, which maintains the alignment of the rotor. Findings From the simulation and experimental results, it can be seen that the proposed controller and observer satisfactorily work for parameter variations, load torque and speed tracking. Originality/value The authenticity of the proposed technique is tested experimentally on two different BLDC motors using low-cost 32-bit STM32F407VG microcontroller. The response of the proposed technique is evaluated by changing motor parameters such as stator resistance, inductance, flux linkage constant and torque constant.
引用
收藏
页码:323 / 352
页数:30
相关论文
共 50 条
  • [21] Simultaneous interconnection and damping assignment passivity-based control: the induction machine case study
    Batlle, Carles
    Doria-Cerezo, Arnau
    Espinosa-Perez, Gerardo
    Ortega, Romeo
    INTERNATIONAL JOURNAL OF CONTROL, 2009, 82 (02) : 241 - 255
  • [22] Interconnection and Damping Assignment Passivity-Based Control Design Under Loss of Actuator Effectiveness
    Liu, Zhong
    Theilliol, Didier
    Yang, Liying
    He, Yuqing
    Han, Jianda
    JOURNAL OF INTELLIGENT & ROBOTIC SYSTEMS, 2020, 100 (01) : 29 - 45
  • [23] Interconnection and damping assignment passivity-based control for a compass-like biped robot
    de-Leon-Gomez, Victor
    Santibanez, Victor
    Sandoval, Jesus
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2017, 14 (04): : 1 - 18
  • [24] Interconnection and Damping Assignment Passivity-Based Control Design Under Loss of Actuator Effectiveness
    Zhong Liu
    Didier Theilliol
    Liying Yang
    Yuqing He
    Jianda Han
    Journal of Intelligent & Robotic Systems, 2020, 100 : 29 - 45
  • [25] Interconnection and damping assignment passivity-based control of port-controlled Hamiltonian systems
    Ortega, R
    van der Schaft, A
    Maschke, B
    Escobar, G
    AUTOMATICA, 2002, 38 (04) : 585 - 596
  • [26] Interconnection and damping assignment passivity-based control:: Towards a constructive procedure -: Part I
    Ortega, R
    García-Canseco, E
    2004 43RD IEEE CONFERENCE ON DECISION AND CONTROL (CDC), VOLS 1-5, 2004, : 3412 - 3417
  • [27] Interconnection and damping assignment passivity-based control:: Towards a constructive procedure -: Part II
    García-Canseco, E
    Astolfi, A
    Ortega, R
    2004 43RD IEEE CONFERENCE ON DECISION AND CONTROL (CDC), VOLS 1-5, 2004, : 3418 - 3423
  • [28] Interconnection and damping assignment passivity-based control of mechanical systems with underactuation degree one
    Acosta, JA
    Ortega, R
    Astolfi, A
    Mahindrakar, AD
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2005, 50 (12) : 1936 - 1955
  • [29] INTERCONNECTION AND DAMPING ASSIGNMENT PASSIVITY-BASED CONTROL OF AN UNDERACTUATED 2-DOF GYROSCOPE
    Cordero, Gustavo
    Santibanez, Victor
    Dzul, Alejandro
    Sandoval, Jesus
    INTERNATIONAL JOURNAL OF APPLIED MATHEMATICS AND COMPUTER SCIENCE, 2018, 28 (04) : 661 - 677
  • [30] Decentralized Control of DC Microgrids Using Interconnection and Damping Assignment Passivity-Based Control Technique: Experimental Verification
    Afkar, Mohammad
    Yuan, Cong
    Gavagsaz-Ghoachani, Roghayeh
    Saksiri, Wiset
    Phattanasak, Matheepot
    Martin, Jean-Philippe
    Pierfederici, Serge
    IEEE ACCESS, 2024, 12 : 136613 - 136627