Fracture strength of endocrown maxillary restorations using different preparation designs and materials

被引:2
|
作者
Al Fodeh, Rami S. [1 ]
Al-Johi, Omer S. [1 ]
Alibrahim, Anas N. [1 ]
Al-Dwairi, Ziad N. [1 ]
Husain, Nadin Al -Haj [2 ,3 ,4 ]
Ozcan, Mutlu [2 ,3 ,5 ]
机构
[1] Jordan Univ Sci & Technol, Fac Dent, Dept Prosthodont, Irbid, Jordan
[2] Univ Zurich, Ctr Dent Med, Div Dent Biomat, Clin Reconstruct Dent, Zurich, Switzerland
[3] Univ Zurich, Ctr Dent Med, Clin Masticatory Disorders & Dent Biomat, Zurich, Switzerland
[4] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[5] Univ Zurich, Clin Prevent Dent Periodontol & Cariol, Ctr Dent Med, Plattenstr 11, CH-8032 Zurich, Switzerland
关键词
Dental materials; Endocrown; Endodontically treated teeth; Lithium discilicate; Multilayer zirconia; Prosthodontics; ENDODONTICALLY TREATED TEETH; BIOMECHANICAL BEHAVIOR; LITHIUM DISILICATE; BITE FORCE; RESISTANCE; POST; CROWNS; TOOTH; CORE;
D O I
10.1016/j.jmbbm.2023.106184
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: This study investigated the impact of preparation design and material types on fracture strength in maxillary premolars endocrowns after thermodynamic aging.Materials and methods: Eighty two-rooted maxillary premolar crowns underwent endodontic treatment (N = 80, n = 10). The teeth were categorized into ten groups (4-mm deep with no intracanal extension lithium disilicate glass ceramic & multilayer zirconia endocrowns (LE0 & ZE0); 4-mm deep with 4-mm intracanal extension in one canal (LE1 & ZE1); 4-mm deep with 2-mm intracanal extensions in both canals (LE2 & ZE2); flat overlays with no endocore (LO & ZO); glass fiber reinforced post & core and crown (LC & ZC)). After cementation, all specimens were subjected to 1500 thermocycles and 1,200,000 chewing cycles with an axial occlusal load of 49 N. A static loading test was performed at a non-axial 45 loading using a universal testing machine and failure modes (Type I: restoration debonding; Type II: restoration fracture; Type III: restoration/tooth complex fracture above bone level; Type IV: restoration/tooth complex fracture below bone level) were evaluated using a stereoscope. Data were ananalzed using 2-way ANOVA and Tukey's tests (alpha = 0.05).Results: The endocrowns manufactured from multilayered zirconia and pressed lithium disilicate glass ceramic exhibited a fracture load ranging between 1334 +/- 332 N and 756 +/- 150 N, with ZC presenting the highest and LE2 the lowest values. The differences were not statistically significant (p > 0.05).Conclusion: All endocrowns tested in this study performed similar considering the different designs and materials tested. The distribution of fracture modes did not differ significantly depending on the design of the restoration and the type of material used.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Fracture strengths of endocrown restorations fabricated with different preparation depths and CAD/CAM materials
    Kanat-Erturk, Burcu
    Saridag, Serkan
    Koseler, Ege
    Helvacioglu-Yigit, Dilek
    Avcu, Egemen
    Yildiran-Avcu, Yasemin
    DENTAL MATERIALS JOURNAL, 2018, 37 (02) : 256 - 265
  • [2] Fracture resistance of maxillary premolars restored with different endocrown designs and materials after artificial ageing
    Ahmed, Mohamed A. A.
    Kern, Matthias
    Mourshed, Bilal
    Wille, Sebastian
    Chaar, Mohamed Sad
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (01) : 141 - 150
  • [3] Influence of different cavity preparation designs on fracture resistance of onlay and overlay restorations using different CAD/CAM materials
    Salman, Gizem On
    Tacir, Ibrahim Halil
    Polat, Zelal Seyfioglu
    Salman, Afsin
    AMERICAN JOURNAL OF DENTISTRY, 2017, 30 (03): : 165 - 170
  • [4] The effect of fiber insertion on fracture strength and fracture modes in endocrown and overlay restorations
    Fildisi, Mehmet Ali
    Dalkilic, Evrim Eliguzeloglu
    MICROSCOPY RESEARCH AND TECHNIQUE, 2022, 85 (05) : 1799 - 1807
  • [5] A 3-dimensional finite element and in vitro analysis of endocrown restorations fabricated with different preparation designs and various restorative materials
    Ural, Cagri
    Caglayan, Esma
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (04): : 586.e1 - 586.e9
  • [6] Effect of different preparation designs and all ceramic materials on fracture strength of molar endocrowns
    Haralur, Satheesh B.
    Alamrey, Alaa Ali
    Alshehri, Shatha Abdulrahman
    Alzahrani, Danyah Saeed
    Alfarsi, Mohammed
    JOURNAL OF APPLIED BIOMATERIALS & FUNCTIONAL MATERIALS, 2020, 18
  • [7] Effect of different ceramic materials and substructure designs on fracture resistance in anterior restorations
    Jo, Eun-Hye
    Huh, Yoon-Hyuk
    Ko, Kyung-Ho
    Park, Chan-Jin
    Cho, Lee-Ra
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (05): : 785 - 792
  • [8] Fracture Resistance and Failure Mode of Endocrown Restorations with Different Remaining Walls and Finish Lines
    Koosha, Sara
    Mostafavi, Azam S.
    Jebelizadeh, Mahdieh S.
    Ghasemi, Mahsa
    Hayerimaybodi, Mahrad
    OPEN DENTISTRY JOURNAL, 2023, 17
  • [9] Acoustic properties of fracture of dental restorative materials and endocrown restorations under quasi-static loading
    Skalskyi, Valentyn
    Makeev, Valentyn
    Stankevych, Olena
    Dubytskyi, Olexandr
    DENTAL MATERIALS, 2020, 36 (05) : 617 - 625
  • [10] Impact of different CAD/CAM materials on internal and marginal adaptations and fracture resistance of endocrown restorations with: 3D finite element analysis
    Shaimaa Ahmed Abo El-Farag
    Fatma Abdallah Elerian
    Abdallah Ahmed Elsherbiny
    Mahy Hassouna Abbas
    BMC Oral Health, 23