Rapid Method To Determine 137Cs, 237Np, and Pu Isotopes in Seawater by SF-ICP-MS

被引:8
|
作者
Zhang, Shuai [1 ,2 ]
Liu, Zhiyong [1 ,3 ,4 ]
Yang, Guosheng [1 ]
Zheng, Jian [1 ]
Pan, Shaoming [2 ]
Aono, Tatsuo [1 ,6 ]
Sakaguchi, Aya [5 ]
机构
[1] Natl Inst Quantum Sci & Technol, Inst Radiol Sci, Inage, Chiba 2638555, Japan
[2] Nanjing Univ, Sch Geog & Oceanog Sci, Nanjing 210023, Peoples R China
[3] Soochow Univ, Sch Radiol & Interdisciplinary Sci RAD X, State Key Lab Radiat Med & Protect, Suzhou 215123, Peoples R China
[4] Soochow Univ, Collaborat Innovat Ctr Radiat Med Jiangsu Higher E, Suzhou 215123, Peoples R China
[5] Univ Tsukuba, Inst Pure & Appl Sci, Tsukuba, Ibaraki 3058577, Japan
[6] Fukushima Inst Res Educ & Innovat, Radioecol Unit, Fukushima 9601295, Japan
关键词
ACCELERATOR MASS-SPECTROMETRY; SEA-WATER; ANTHROPOGENIC RADIONUCLIDES; MARINE-ENVIRONMENT; SEDIMENT SAMPLES; NP; PLUTONIUM; AM; ACID; PERFORMANCE;
D O I
10.1021/acs.analchem.3c02702
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Neptunium-237, owing to its long half-life (t(1/2) = 2.14 x 10(6) year) and similar conservatism to Cs-137, has the potential to replace Cs-137 for water mass circulation studies on decades and even longer time scales. A new method for the determination of Cs-137, Np-237, and Pu isotopes in seawater samples was proposed to solve the difficulty of Np-237 analysis in seawater. The developed method includes the separation technique of ammonium phosphomolybdate (AMP) adsorption for Cs-137 and anion exchange chromatography for Np-237 and Pu, a measurement technique of gamma spectrometry for Cs-137 and SF-ICP-MS for Np-237 and Pu isotopes. Pu-242 as a pseudo isotope dilution tracer for Np, the negligible chemical fractionation between Np-237 and Pu-242 of 1.02 +/- 0.06 (k = 2) was obtained by implementing sophisticated control of the redox system and chromatographic elution optimization. The analytical results for the International Atomic Energy Agency Certified Reference Materials (IAEA-443) agreed with the reference values, showing chemical yields of 65-88%, U decontamination factor above 10(6) level, and improved sample throughput (5 days for 12 samples). Meanwhile, the lower method detection limits (MDLs) of Np-237, Pu-239, and Pu-240 were 1.3 x 10(-3), 0.065, and 0.15 mu Bq L-1 for 15 L seawater, respectively. Results obtained by the developed method can be used to evaluate the impact on the marine ecological system of the planned marine discharge of Fukushima decontaminated wastewater. Working toward that purpose, we are the first to report the Np-237 activity concentration in Pacific Ocean seawater sampled near the station site, and we obtained the value of 0.122-0.154 mu Bq L-1.
引用
收藏
页码:16892 / 16901
页数:10
相关论文
共 47 条
  • [31] Concurrent determination of 237Np and Pu isotopes using ICP-MS: analysis of NIST environmental matrix standard reference materials 4357, 1646a, and 2702
    Matteson, Brent S.
    Hanson, Susan K.
    Miller, Jeffrey L.
    Oldham, Warren J., Jr.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2015, 142 : 62 - 67
  • [32] Sorption of 237Np(V), 238U(VI), and 137Cs on clays: Role of surface films of Fe(III) compounds
    M. N. Sabodina
    E. V. Zakharova
    S. N. Kalmykov
    K. V. Pokholok
    A. A. Menyailo
    Radiochemistry, 2008, 50 (1) : 91 - 97
  • [33] Limiting spectroscopic interferences of 239Pu and 237Np in a UO2 matrix using LA-ICP-MS
    Campbell, Keri
    Unger, Aaron
    Kerlin, William
    Hartmann, Thomas
    Bertoia, Julie
    Judge, Elizabeth
    Dirmyer, Matthew
    Czerwinski, Ken
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 310 (02) : 533 - 540
  • [34] Simultaneous determination of femtogram levels of 237Np, 239Pu, and 240Pu in environmental solid samples using extraction chromatography and ICP-MS/MS
    Huang, Zhao
    Hou, Xiaolin
    Qiao, Jixin
    Zhao, Xue
    TALANTA, 2023, 265
  • [35] A rapid method for 137Cs preconcentration from seawater by using polyaluminum chloride as coagulant
    Wan-Ling Chen
    Chia-Yin Pan
    Hsin-Hsiung Huang
    Wen-Hsien Tsai
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 329 : 1345 - 1351
  • [36] A rapid method for 137Cs preconcentration from seawater by using polyaluminum chloride as coagulant
    Chen, Wan-Ling
    Pan, Chia-Yin
    Huang, Hsin-Hsiung
    Tsai, Wen-Hsien
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 329 (03) : 1345 - 1351
  • [37] Limiting spectroscopic interferences of 239Pu and 237Np in a UO2 matrix using LA-ICP-MS
    Keri Campbell
    Aaron Unger
    William Kerlin
    Thomas Hartmann
    Julie Bertoia
    Elizabeth Judge
    Matthew Dirmyer
    Ken Czerwinski
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 310 : 533 - 540
  • [38] Determination of Pu isotopes in urine samples by a pseudo-isotope dilution method using non-isotopic tracer 237Np
    Qin, Ning
    Zheng, Jian
    Yang, Guosheng
    Kim, Eunjoo
    Kurihara, Osamu
    TALANTA, 2025, 289
  • [39] Uranium comparison by means of AMS and ICP-MS and Pu and 137Cs results around an Italian Nuclear Power Plant
    De Cesare, M.
    Tims, S. G.
    Fifield, L. K.
    HEAVY ION ACCELERATOR SYMPOSIUM 2014, 2015, 91
  • [40] Simple and fast method for the analysis of 236U, 237Np, 239PU and 240Pu from seawater samples by Accelerator Mass Spectrometry
    Lopez-Lora, Mercedes
    Levy, Isabelle
    Chamizo, Elena
    TALANTA, 2019, 200 : 22 - 30