Optimum angle of reflective mirrors integrated on PV/Trombe wall: An experimental assessment

被引:5
|
作者
Ibrahim, Ateka K. [1 ]
Ahmed, Omer K. [1 ]
Algburi, Sameer [2 ]
机构
[1] Northern Tech Univ, Mosul, Iraq
[2] Al Kitab Univ, Altun Kupri, Iraq
关键词
Photovoltaic Trombe wall; Reflective mirrors; Optimum angle; PV-TROMBE WALL; FLAT-PLATE; THERMAL PERFORMANCE; COLLECTOR; DESIGN; ENHANCEMENT; MODULES; FLUID;
D O I
10.1016/j.egyr.2023.07.020
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The provision of electricity and hot water is among the most significant human requirements at present. A photovoltaic/Trombe wall (PV/TW) system concurrently provides warm water, hot air, and electrical power for domestic usage. To optimize the amount of incident solar radiation, reflective mirrors were put on each side of the front face of the PV/TW system. The current article aims to determine the optimal angle for these mirrors that improve the thermal and electrical efficiency of the system.The findings indicated the utilization of DC fans, reflecting mirrors and water flowing across a heat exchanger improves thermal and electrical performance. The best angle for the impact of reflective mirrors to enhance electrical efficiency is the angle (30 degrees) when using water cooling, which led to a decrease in the temperature of the photovoltaic panel and thus raised the electrical efficiency to reach (13.86 %). Also, the results confirmed that the system's thermal efficiency that uses two cooling fluids is the highest relative to the other cases, and the system's thermal efficiency that contains mirrors at 30 degrees was higher than the other two angles. Finally, the addition of reflective mirrors is a favorable option for obtaining higher energy compared to the system without mirrors.& COPY; 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:591 / 603
页数:13
相关论文
共 26 条
  • [21] Performance of Bi-fluid PV/thermal collector integrated with phase change material: Experimental assessment
    Awad, Muthanna Mohammed
    Ahmed, Omer Khalil
    Ali, Obed Majeed
    SOLAR ENERGY, 2022, 235 : 50 - 61
  • [22] Calculation of Optimum Fixed Tilt Angle of PV Panels Depending on Solar Angles and Comparison of the Results with Experimental Study Conducted in Summer in Bilecik, Turkey
    Karafil, Akif
    Ozbay, Harun
    Kesler, Metin
    Parmaksiz, Huseyin
    2015 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2015, : 971 - 976
  • [23] Experimental assessment of concrete masonry units integrated with insulation and phase change material: A wall-pattern study
    Zhang, Yuan
    Sun, Xiaoqin
    Medina, Mario A.
    ENERGY, 2024, 289
  • [24] A hybrid PV thermal (water or air) wall system integrated with double air channel and phase change material: A continuous full-day seasonal experimental research
    Xu, Lijie
    Ji, Jie
    Cai, Jingyong
    Ke, Wei
    Tian, Xinyi
    Yu, Bendong
    Wang, Jun
    RENEWABLE ENERGY, 2021, 173 : 596 - 613
  • [25] The design, experimental and numerical study on a novel double-skin glass ventilation wall with PV blind integrated with thermal catalytic materials for synergistic energy generation and air purification
    Wang, Yiting
    Hu, Xuan
    Gu, Tao
    Ji, Jie
    Li, Niansi
    Yu, Bendong
    ENERGY, 2024, 313
  • [26] Exergetic and environment assessment of linear fresnel concentrating photovoltaic systems integrated with a porous-wall mini-channel heat sink: Outdoor experimental tests
    Wang, Yacheng
    Xia, Guodong
    Zhou, Wenbin
    Zhao, Shuai
    Zhao, Pengsheng
    ENERGY, 2024, 306