Experimental Development of the Horizontal Drain Water Heat Recovery Unit

被引:4
|
作者
Kordana-Obuch, Sabina [1 ]
Starzec, Mariusz [1 ]
机构
[1] Rzeszow Univ Technol, Dept Infrastructure & Water Management, Powstancow Warszawy 6, PL-35959 Rzeszow, Poland
关键词
domestic hot water; greywater; shower; energy consumption; CO2; emission; energy efficiency; heat exchanger; waste heat; CONSUMPTION;
D O I
10.3390/en16124634
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The increase in energy demand, the scarcity of resources, as well as the adverse environmental impact of burning fossil fuels make it necessary to diversify the energy sources used. This also applies to the residential sector, which accounts for a significant proportion of global energy consumption. Particular attention should be paid to water heating, as the importance of this process in the energy balance of buildings is steadily increasing. One of the methods used to decrease energy consumption for heating water is to recover heat from greywater. However, commercially available horizontal drain water heat recovery (DWHR) units are characterized by low effectiveness, which creates a need for further research to improve it. The aim of the paper was to evaluate the possibility of improving the effectiveness of a circular horizontal DWHR unit through the use of baffles. Six different baffle models for installation in the greywater section of the heat exchanger were analyzed. The tests were conducted under the assumption of the installation of the DWHR unit on the horizontal shower waste pipe. They showed that the effectiveness of the unit equipped with baffles was higher by several to as much as 40% compared to the DWHR unit without baffles. This is tantamount to an increase in annual financial savings resulting from greywater heat recovery, as well as a reduction in CO2 emissions into the atmosphere. However, it was not possible to clearly identify the optimum baffle model. In any case, the selection should consider the hydraulic conditions in the heat exchanger before installing the baffles. The results can provide guidance for companies interested in bringing new equipment and technologies to the market.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Analyzing the efficiency of a heat pump assisted drain water heat recovery system that uses a vertical inline heat exchanger
    Wallin, Jorgen
    Claesson, Joachim
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2014, 8 (08) : 109 - 119
  • [42] Experimental Heat Transfer Coefficients of Waste Heat Recovery Unit in Detergent Manufacturing Process
    Bumroongsri, P.
    Witchayanuwat, W.
    Kheawhom, S.
    EXPERIMENTAL HEAT TRANSFER, 2013, 26 (01) : 114 - 125
  • [43] Experimental and simulation performance optimization of an exhaust air heat recovery heat pump unit
    Wang, Zhiyi
    Lu, Xiaohong
    Wang, Gaoyuan
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2022, 17 : 686 - 695
  • [44] Experimental performance evaluation of a novel heat pump water heater assisted with shower drain water
    Dong, Jiankai
    Zhang, Zhuo
    Yao, Yang
    Jiang, Yiqiang
    Lei, Bo
    APPLIED ENERGY, 2015, 154 : 842 - 850
  • [45] Investigating the Performance of Two Types of Solar Domestic Water Heating (SDWH) Systems with Drain Water Heat Recovery through Computer Simulation and Experimental Analysis
    Tanha, Kamyar
    Fung, Alan S.
    Leong, Wey H.
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 2, 2012, 118 : 214 - 221
  • [46] Experimental Evaluation of a Total Heat Recovery Unit with Polymer Membrane Foils
    Fang, Lei
    Yuan, Shu
    Nie, Jinzhe
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 235 - 242
  • [47] The experimental research on the characteristics of AC system with condenser heat recovery unit
    Zhang, WJ
    Gao, XD
    Wang, HX
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1377 - 1381
  • [48] Development and experimental validation of high temperature heat pump for heat recovery
    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    Hsi An Chiao Tung Ta Hsueh, 2008, 10 (1309-1312):
  • [49] An experimental study on heat transfer characteristics of paraffin wax in horizontal double pipe heat latent heat storage unit
    Jesumathy, S. P.
    Udayakumar, M.
    Suresh, S.
    Jegadheeswaran, S.
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2014, 45 (04) : 1298 - 1306
  • [50] Decentralized drain water heat recovery: A probabilistic method for prediction of wastewater and heating system interaction
    Spriet, Jan
    McNabola, Aonghus
    ENERGY AND BUILDINGS, 2019, 183 : 684 - 696