Quantifying metallic components in aerosol filter samples using micro-synchrotron radiation X-ray fluorescence: With quartz filter as an example

被引:2
|
作者
Zhang, Yidan [1 ]
Xu, Yifan [1 ]
Peng, Bo [1 ]
Chen, Wu [1 ]
Cui, Xiaoyu [1 ]
Zhang, Tianle [1 ,2 ]
Chen, Xi [1 ,3 ]
Yao, Yuan [1 ]
Wang, Mingjin [1 ,4 ]
Liu, Junyi [1 ,2 ]
Zheng, Mei [1 ,2 ]
Zhu, Tong [1 ]
机构
[1] Peking Univ, Coll Environm Sci & Engn, BIC ESAT & SKL ESPC, Beijing 100871, Peoples R China
[2] Peking Univ, Ctr Environm & Hlth, Beijing 100871, Peoples R China
[3] Shenzhen Inst Bldg Res Co Ltd, Hebei Technol Innovat Ctr Human Settlement Green B, Xiongan, Peoples R China
[4] Hefei Univ Technol, Sch Resources & Environm Engn, Hefei 230009, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Micro-synchrotron radiation; Metallic components; Personal exposure; X-ray fluorescence; QFFs; AROMATIC-HYDROCARBONS PAHS; RESOLVED TRACE-ELEMENTS; PARTICULATE MATTER; AMBIENT AIR; PM2.5; FIBER; PM10; XRF; SPECTROMETRY; EXHAUST;
D O I
10.1016/j.atmosenv.2023.120205
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Metals in atmospheric fine particulate matter (PM2.5) are presumed to have toxic effects. For environmental epidemiological studies, measuring the metallic components of PM2.5 collected by personal samplers and quartz fiber filters (QFF) has two key advantages: reducing exposure misclassification and enabling analyses of multiple (organic and inorganic) components on a single filter. We developed a sensitive, low-sample-consumption method to quantify the metallic components of PM2.5 collected on QFFs using micro-synchrotron radiation Xray fluorescence (mu-SRXRF). Teflon filter is used here as a reference to test the substrate applicability of QFF. This method requires only a 5-mm-diameter portion of a QFF and can simultaneously quantify 15 metals with atomic numbers Z = 19-34 (i.e., K-Se, excluding Sc). The analysis time for each sample was 120-360 s, and the method detection limits were 0.04-36.6 ng/m3. We validated this method by performing cross-comparisons with two external methods: offline inductively coupled plasma mass spectrometry (ICP-MS) and online X-ray fluorescence (XRF). The slopes of the linear fits between the mu-SRXRF and offline ICP-MS methods varied from 0.40 to 1, with R2 values ranging from 0.62 to 0.98. The slopes of the linear fits between the mu-SRXRF and online XRF methods were between 0.29 and 0.89, with R2 values ranging from 0.39 to 0.80. We applied the proposed method to analyze 391 personal PM2.5 samples collected in an epidemiological study conducted in urban Beijing. By comparing the results with the ambient concentrations from a fixed monitoring site, we found that the con-centrations of some metallic components in personal PM2.5 samples were significantly different from those in the corresponding fixed-site samples, with up to an order of magnitude difference. Because personal sampling can reduce the potential for exposure misclassifications, the high-resolution temporal analysis of metallic compo-nents in personal samples using the mu-SRXRF method could be a useful approach for exploring the health risks and identifying the sources of metallic components of PM2.5.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Aerosol filter analysis using scanning micro X-ray fluorescence
    Havrilla, George J.
    Montoya, Velma M.
    Tandon, Lav
    LaMont, Stephen P.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 234
  • [2] Micro-synchrotron X-ray fluorescence of cadmium-challenged corn roots
    Naftel, SJ
    Martin, RR
    Sham, TK
    Macfie, SM
    Jones, KW
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2001, 119 (2-3) : 235 - 239
  • [3] PREPARATION OF QUARTZ FIBER FILTER STANDARDS FOR X-RAY-FLUORESCENCE ANALYSIS OF AEROSOL SAMPLES
    HAUPT, O
    KLAUE, B
    SCHAEFER, C
    DANNECKER, W
    X-RAY SPECTROMETRY, 1995, 24 (05) : 267 - 275
  • [4] Using micro-synchrotron radiation x-ray fluorescence (μ-SRXRF) for trace metal imaging in the development of MRI contrast agents for prostate cancer imaging
    Dao, E.
    Jordan, M. V. Clavijo
    Geraki, K.
    Martins, A. F.
    Chirayil, S.
    Sherry, A. D.
    Farquharson, M. J.
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2022, 74
  • [5] Using Micro-Synchrotron Radiation X-Ray Fluorescence (Μ-Srxrf) for Trace Metal Imaging in the Development of MRI Contrast Agents for Prostate Cancer Imaging
    Dao, Erica
    Jordan, M.V. Clavijo
    Geraki, K.
    Martins, A.F.
    Chirayil, S.
    Sherry, A.D.
    Farquharson, M.J.
    SSRN, 2022,
  • [6] X-Ray Absorption Effect in Aerosol Samples Collected on Filter Media
    Mecchia, Marco
    Pretorius, Cecilia
    Stacey, Peter
    Mattenklott, Markus
    Incocciati, Emma
    SILICA AND ASSOCIATED RESPIRABLE MINERAL PARTICLES, 2014, 1565 : 139 - 168
  • [7] Application of combined micro-proton-induced X-ray emission and micro-synchrotron radiation X-ray fluorescence techniques for the characterization of impact materials around Barringer Meteor Crater
    Uzonyi, I
    Szöör, G
    Vekemans, B
    Vincze, L
    Rózsa, P
    Szabó, G
    Somogyi, A
    Adams, F
    Kiss, AZ
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) : 1717 - 1723
  • [8] X-RAY OPTICS FOR SYNCHROTRON-RADIATION-INDUCED X-RAY MICRO FLUORESCENCE AT THE EUROPEAN SYNCHROTRON-RADIATION FACILITY, GRENOBLE
    VINCZE, L
    JANSSENS, K
    ADAMS, F
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 613 - 616
  • [9] Bivalve Characterization Using Synchrotron Micro X-Ray Fluorescence
    Jones, K. W.
    Bronson, S.
    Brink, P.
    Gordon, C.
    Mosher-Smith, K.
    Brown, M.
    Chaudhry, S.
    Rizzo, A.
    Sigismondi, R.
    Whitehurst, M.
    Lukaszewski, A.
    Kranz, D.
    Bland, K.
    Gordan, D.
    Lobel, J.
    Sullivan, J.
    Metzger, M.
    O'Shea, C.
    Harris, C.
    Arezzo, R.
    Kambhampati, M. S.
    ACTA PHYSICA POLONICA A, 2009, 115 (02) : 477 - 481
  • [10] SAMPLES FOR X-RAY-FLUORESCENCE ANALYSIS USING SYNCHROTRON RADIATION
    KHVOSTOVA, VP
    TRUNOVA, VA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 261 (1-2): : 295 - 300