3D simulation of percutaneous sustentaculum tali screw insertion in calcaneal fractures

被引:0
|
作者
Li, Xian [1 ,2 ]
Wang, Xiao-ke [1 ]
Yu, Lian-kui [2 ]
Zhang, Chao [2 ]
Zhao, Ming-ming [2 ]
Yan, Jun [2 ]
Han, Li-ren [2 ]
机构
[1] Weifang Med Univ, Sch Clin Med, Weifang, Peoples R China
[2] Liaocheng Peoples Hosp, Dept Orthopaed Surg, Liaocheng, Peoples R China
关键词
Calcaneal fracture; Percutaneous screw fixation; Sustentaculum tali; Digital measurement; SANDERS TYPE-II; PLACEMENT; FIXATION;
D O I
10.1186/s12891-023-06748-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background In calcaneal fractures, the percutaneous screw fixation (PSF) is currently considered to be the better choice, but it is difficult to accurately place the screw into the sustentaculum tali (ST) during the operation. In this study, the ideal entry point, angle, diameter and length of the screw were calculated by simulating the operation process. Methods We retrospectively collected the calcaneus computed tomography (CT) scans of 180 adults, DICOM-formatted CT-scan images of each patient were imported into Mimics software to establish calcaneus model. Virtual screws were placed on the lateral of the posterior talar articular surface (PTAS), the lateral edge of the anterior process of calcaneus (APC), and the calcaneal tuberosity, respectively, the trajectory and size of the screws were calculated. Results The mean maximum diameter of the PTAS screw was 42.20 +/- 3.71 mm. The vertical distance between the midpoint of the APC optimal screw trajectory and the lowest point of the tarsal sinus was 10.67 +/- 1.84 mm, and the distance between the midpoint of the APC optimal screw trajectory and the calcaneocuboid joint was 5 mm similar to 19.81 +/- 2.08 mm. The mean maximum lengths of APC screws was 44.69 +/- 4.81 mm, and the Angle between the screw and the coronal plane of the calcaneus from proximal to distal was 4.72 degrees +/- 2.15 degrees to 20.52 degrees +/- 3.77 degrees. The optimal point of the maximum diameter of the calcaneal tuberosity screw was located at the lateral border of the achilles tendon endpoint. The mean maximum diameters of calcaneal tuberosity screws was 4.46 +/- 0.85 mm, the mean maximum lengths of screws was 65.31 +/- 4.76 mm. We found gender- dependent differences for the mean maximum diameter and the maximum length of the three screws. Conclusions The study provides effective positioning for percutaneous screw fixation of calcaneal fractures. For safer and more efficient screw placement, we suggest individualised preoperative 3D reconstruction simulations. Further biomechanical studies are needed to verify the function of the screw.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Percutaneous subtalar joint screw fixation of comminuted calcaneal fractures: a salvage procedure
    Malik, Catherine
    Najefi, Ali Asgar
    Patel, Amit
    Vris, Alexandros
    Malagelada, Francesc
    Parker, Lee
    Heidari, Nima
    Jeyaseelan, Lucky
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (05) : 4043 - 4051
  • [22] The study of screw placement parameters for Ogawa type I acromial fractures by 3D simulation
    Zhang, Wei
    Sun, Zhongye
    Li, Weiyan
    Yan, Jun
    Han, Liren
    Han, Shizhang
    Yang, Xiaofei
    Zhao, Bei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [23] Percutaneous reduction and screw fixation for all types of intra-articular calcaneal fractures
    Ebrahimpour A.
    Kord M.H.C.
    Sadighi M.
    Chehrassan M.
    Najafi A.
    Sajjadi M.M.
    MUSCULOSKELETAL SURGERY, 2021, 105 (1) : 97 - 103
  • [24] The study of screw placement parameters for Ogawa type I acromial fractures by 3D simulation
    Wei Zhang
    Zhongye Sun
    Weiyan Li
    Jun Yan
    Liren Han
    Shizhang Han
    Xiaofei Yang
    Bei Zhao
    Journal of Orthopaedic Surgery and Research, 16
  • [25] Sinus Tarsi Approach With Percutaneous Screw Fixation for Intra-Articular Calcaneal Fractures
    Xu, Hao
    Ju, Jihui
    Hou, Ruixing
    Liu, Yuefei
    Zhou, Rong
    Chen, Lucheng
    Hu, Changqing
    Yang, Liang
    JOURNAL OF FOOT & ANKLE SURGERY, 2022, 61 (04): : 792 - 797
  • [26] Comparison of 2D and 3D navigation techniques for percutaneous screw insertion into the scaphoid: Results of an experimental cadaver study
    Catala-Lehnen, Philip
    Nuechtern, Jakob V.
    Briem, Daniel
    Klink, Thorsten
    Rueger, Johannes M.
    Lehmann, Wolfgang
    COMPUTER AIDED SURGERY, 2011, 16 (06) : 280 - 287
  • [27] 3D navigated osteosynthesis of calcaneal fractures Open and minimally invasive techniques
    Ruebberdt, A.
    Hofbauer, V. R.
    Herbort, M.
    Loehrer, L.
    Ochman, S.
    Raschke, M. J.
    UNFALLCHIRURG, 2009, 112 (01): : 15 - 22
  • [28] Treatment of Displaced Intra-Articular Calcaneal Fractures with Closed Reduction and Percutaneous Screw Fixation
    Tomesen, T.
    Biert, J.
    Frolke, J. P. M.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (10): : 920 - 928
  • [29] Immediate percutaneous sacroiliac screw insertion for unstable pelvic fractures: is it safe enough?
    Acker, A.
    Perry, Z. H.
    Blum, S.
    Shaked, G.
    Korngreen, A.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2018, 44 (02) : 163 - 169
  • [30] Immediate percutaneous sacroiliac screw insertion for unstable pelvic fractures: is it safe enough?
    A. Acker
    Z. H. Perry
    S. Blum
    G. Shaked
    A. Korngreen
    European Journal of Trauma and Emergency Surgery, 2018, 44 : 163 - 169