Mechanical Device Malfunction of the HeartMate II Versus the HeartMate 3 Left Ventricular Assist Device: The Rotterdam Experience

被引:1
|
作者
van der Heiden, Cornelis W. [1 ]
Zijderhand, Casper F. [1 ,2 ]
Veen, Kevin M. [2 ]
Constantinescu, Alina A. [1 ]
Manintveld, Olivier C. [1 ]
Brugts, Jasper J. [1 ]
Bekkers, Jos A. [2 ]
Birim, Ozcan [2 ]
Bogers, Ad J. J. C. [2 ]
Caliskan, Kadir [1 ]
机构
[1] Erasmus MC Univ Med Ctr Rotterdam, Dept Cardiol, Thoraxctr, Room RG 431,Dr Molewaterpl 40, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus MC Univ Med Ctr Rotterdam, Dept Cardiothorac Surg, Thoraxctr, Rotterdam, Netherlands
关键词
left ventricular assist device; HeartMate II; HeartMate; 3; mechanical device malfunction; CIRCULATORY SUPPORT;
D O I
10.1097/MAT.0000000000001877
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Mechanical device malfunction remains a known issue in left ventricular assist devices (LVADs). We investigated the incidence of mechanical device malfunction in the HeartMate II and HeartMate 3 LVADs. We conducted a retrospective study of all HeartMate II and HeartMate 3 LVADs implanted in our center. We evaluated major malfunction, potential major malfunction, minor malfunction, and need of device exchange. In total, 163 patients received an LVAD; in 63 (39%) a HeartMate II, and in 100 (61%) a HeartMate 3, median support time of respectively 24.6 months (interquartile range [IQR]: 32.4) and 21.1 months [IQR: 27.2]. Mechanical device malfunction, consisting of both major and potential major malfunction, occurred significantly less in the HeartMate 3 patients with a hazard ratio (HR) of 0.37 (95% confidence interval [CI]: 0.15-0.87, p = 0.022). Major malfunction alone occurred significantly less in HeartMate 3 patients with a HR of 0.18 (95% CI: 0.05-0.66, p = 0.009). HeartMate 3 patients had a significantly decreased hazard of a pump or outflow graft exchange (HR 0.13, 95% CI: 0.08-0.81, p = 0.008). System controller defects occurred significantly less in HM 3 patients (p = 0.007), but battery-clips defects occurred significantly more in HM 3 patients (p = 0.039). Major device malfunction including pump or outflow graft exchange occurred significantly less in HeartMate 3 compared to HeartMate II, while minor malfunctions were similar. Periodical assessment of the technical integrity of the device remains necessary during long-term LVAD support.
引用
收藏
页码:E80 / E85
页数:6
相关论文
共 50 条
  • [21] Recovery Plug for HeartMate 3 Left Ventricular Assist Device
    Mulzer, J.
    Potapov, E.
    Kaufmann, F.
    Mueller, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S480 - S480
  • [22] Discontinuation of Aspirin in Heartmate 3 Left Ventricular Assist Device
    Lim, S.
    Ranasinghe, A.
    Howell, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S72 - S72
  • [23] Recovery plug for HeartMate 3 left ventricular assist device
    Mulzer, Johanna
    Faerber, Gloria
    Kaufmann, Friedrich
    Potapov, Evgenij V.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (02): : E35 - E37
  • [24] Single-Center Experience With HeartMate II Left Ventricular Assist Device Explantation
    Tchantchaleishvili, Vakhtang
    Cheyne, Christina
    Sherazi, Saadia
    Melvin, Amber L.
    Hallinan, William
    Chen, Leway
    Massey, Howard Todd
    ARTIFICIAL ORGANS, 2016, 40 (12) : 1145 - 1149
  • [25] Clinical Experience of HeartMate II to HeartWare Left Ventricular Assist Device Exchange: A Multicenter Experience
    Agarwal, Richa
    Kyvernitakis, Andreas
    Soleimani, Behzad
    Milano, Carmelo A.
    Davis, Robert Patrick
    Kennedy, Jamie L. W.
    Yarboro, Leora
    Benza, Raymond L.
    Moraca, Robert J.
    Bailey, Stephen H.
    ANNALS OF THORACIC SURGERY, 2019, 108 (04): : 1178 - 1182
  • [26] Progression of Valvular Insufficiency with the Heartmate 3 Left Ventricular Assist Left Ventricular Assist Device: An Institutional Experience
    Kilcoyne, M. F.
    Bhandari, K.
    Ghannam, A.
    Kwon, J. H.
    McDonald, W.
    Welch, B.
    Shorbajji, K.
    Kilic, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S136 - S136
  • [27] Technical and Mechanical Problems and Failures of HeartMate II versus HeartMate 3: The Rotterdam Experience
    van der Heiden, C. W.
    Veen, K.
    Constantinescu, A. C.
    Manintveld, O.
    Brugts, J. J.
    Bekkers, J. A.
    Birim, O.
    Bogers, A. J.
    Caliskan, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S467 - S467
  • [28] Identification of device malfunction in patients supported with the HeartMate XVE left ventricular assist system
    Haft, Jonathan W.
    Suzuki, Yoshi
    Aaronson, Keith D.
    Dyke, David B.
    Wright, Susan
    Poirier, Victor L.
    Pagani, Francis D.
    ASAIO JOURNAL, 2007, 53 (03) : 298 - 303
  • [29] Outcomes and Readmissions After Continuous Flow Left Ventricular Assist Device: Heartmate II Versus Heartware Ventricular Assist Device
    Tuncer, O. N.
    Kemaloglu, C.
    Erbasan, O.
    Golbasi, I.
    Turkay, C.
    Bayezid, O.
    TRANSPLANTATION PROCEEDINGS, 2016, 48 (06) : 2157 - 2161
  • [30] Diagnosis and successful treatment of a unique form of malfunction of the Heartmate left ventricular assist device
    Jahania, S
    Onsager, DR
    Weigel, TL
    Canver, CC
    Love, RB
    Mentzer, RM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 114 (01): : 143 - 144