Start-up strategy of mixed-flow pump system with impulse operation

被引:11
|
作者
Ren, Zhiying [1 ]
Sun, Mingkang [1 ,2 ]
Zhang, Jinsong [2 ]
Wang, Xinlong [3 ]
Huang, Zhenwei [4 ]
Xu, Jin [5 ]
Huang, Chuibing [6 ]
机构
[1] Fuzhou Univ, Inst Met Rubber & Vibrat Noise, Sch Mech Engn & Automat, Fuzhou 350116, Peoples R China
[2] Tsinghua Univ, Dept Energy & Power Engn, Beijing 100084, Peoples R China
[3] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[4] Huazhong Univ Sci & Technol, Sch Naval Architecture & Ocean Engn, Wuhan 430074, Peoples R China
[5] Naval Univ Engn, Natl Key Lab Sci & Technol Vessel Integrated Power, Wuhan 430033, Peoples R China
[6] Naval Univ Engn, Coll Elect Engn, Wuhan 430033, Peoples R China
基金
中国国家自然科学基金;
关键词
Evaluation function; Turbulent kinetic energy; Impact head; Speed scheme; CENTRIFUGAL PUMP; TRANSIENT CHARACTERISTICS; PERFORMANCE; SIMULATION;
D O I
10.1016/j.oceaneng.2023.114058
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
The impact head, tip leakage vortex, and pressure pulsation during start-up can cause vibration and noise in the pump, and affect its hydraulic performance. The linear speed start-up method cannot solve the impact head and vibration problems. Therefore, in this study, a mixed-flow pump was investigated to explore the influence of different speed start-up schemes on the flow field and to optimize them. The rated speed was set to 1634 r/min, and numerical simulations of different start-up schemes were carried out using the standard k-e model. Furthermore, the turbulent kinetic energy distribution of the inlet and outlet sections of the mixed-flow pump during different start-up schemes was provided. In addition, the normalized helicity and blade surface pressure for different start-up schemes were compared. Finally, an evaluation function was proposed to evaluate the stability of the flow field during start-up. The results showed that the evaluation function had four factors related to speed and acceleration during start-up. Factors alpha and gamma were obtained based on the acceleration and speed at 0.2 s and 0.42 s during start-up, respectively. Factor beta was affected by the time taken to reach the rated speed. Parameter delta was determined by the acceleration of the period before reaching the rated speed. Based on the evaluation function, a theoretical scientific selection of speed start-up scheme is proposed to improve the stability of the flow field in the pump during start-up.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Start-up and Operation of the Ormen Lange Flowlines
    Burns, Catherine
    Lorimer, Susan
    Hartenhof, Micha
    Vanvik, Torgeir
    PROCEEDINGS OF THE EIGHTEENTH (2008) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 2, 2008, : 1 - +
  • [42] START-UP AND OPERATION OF EXOTHERMIC BATCH PROCESSES
    HUGO, P
    CHEMIE INGENIEUR TECHNIK, 1980, 52 (09) : 712 - 723
  • [43] Nitrification facilities start-up and initial operation
    Bailey, W.F.
    Bonomo, J.D.
    Jones, E.R.
    1600, (55):
  • [44] NITRIFICATION FACILITIES START-UP AND INITIAL OPERATION
    BAILEY, WF
    BONOMO, JD
    JONES, ER
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1983, 55 (03): : 221 - 228
  • [45] Research on start-up strategy of vehicle mounted heat pump air conditioning compressor
    Chen, Hongyu
    Cheng, Anyu
    Li, Sheng
    Wang, Rui
    2023 35TH CHINESE CONTROL AND DECISION CONFERENCE, CCDC, 2023, : 2088 - 2093
  • [46] Valve serves both start-up, full-flow operation functions
    Johnsen, Oivind
    Smirl, Paul A.
    Pipe Line and Gas Industry, 82 (05):
  • [47] Numerical Simulation of Inlet Flow Characteristics of Mixed Flow Pumps during Start-up
    Li W.
    Ma L.
    Shi W.
    Ji L.
    Li E.
    1600, Chinese Mechanical Engineering Society (32): : 666 - 673and680
  • [48] Cavitation-vibration correlation of a mixed flow pump under steady state and fast start-up conditions by experiment
    Lu, Yangping
    Tan, Lei
    Han, Yadong
    Liu, Ming
    OCEAN ENGINEERING, 2022, 251
  • [49] LAMINAR START-UP FLOW IN A PIPE
    PATIENCE, GS
    MEHROTRA, AK
    OTIS, DR
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1987, 54 (01): : 243 - 244
  • [50] LAMINAR START-UP FLOW IN A PIPE
    OTIS, DR
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1985, 52 (03): : 706 - 711