Feasibility study on energy harvesting with thermoelectric generators in a photovoltaic-ground source heat pump system

被引:0
|
作者
Chae, Hobyung [1 ]
Bae, Sangmu [1 ]
Jeong, Jae-Weon [3 ]
Nam, Yujin [2 ]
机构
[1] Pusan Natl Univ, Res Inst Ind Technol, Busan 46241, South Korea
[2] Pusan Natl Univ, Dept Architectural Engn, Busan 46241, South Korea
[3] Hanyang Univ, Coll Engn, Dept Architectural Engn, Seoul 04763, South Korea
基金
新加坡国家研究基金会;
关键词
Thermoelectric generator; Energy harvesting; Feasibility study; Hybrid system; Generated electricity; HIGH-PERFORMANCE; PROTOTYPE; EXCHANGER; DESIGN;
D O I
10.1016/j.egyr.2023.11.023
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermoelectric generators (TEGs) harness temperature differences to produce electricity and hold promise for diverse industrial applications. However, their limited conversion efficiency casts doubt on their role in achieving energy independence. This study introduces an advanced technique that exploits temperature gradients in water pipes, utilizing supplementary TEGs to augment power generation. This method maintains a stable temperature gradient for TEG operation. Additionally, TEG power output can be efficiently modulated via flow control. In the feasibility evaluation for residential settings, the temperature fluctuations across each system unit were analyzed. In the active system, the chosen sites for TEG integration were units equipped to manage heat transfer using working fluids. The inlet and outlet temperatures were calculated for photovoltaic-thermal (PVT) systems, ground heat exchangers (GHEs), and heat storage tanks (HSTs). The electricity produced by the TEGs was benchmarked against their conversion efficiency, zT. The results indicated that the TEGs yielded 10.95 kWh of electricity when systematically implemented in each unit. To realize a zero-energy building, an area of 64.5 m2 per unit is necessitated for TEG deployment, given a zT value of 1.
引用
收藏
页码:71 / 82
页数:12
相关论文
共 50 条
  • [21] Feasibility analysis of heating with solar energy-ground source heat pump system in inner Mongolian areas
    Jin G.
    Chen Z.
    Guo S.
    Hao N.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (04): : 334 - 341
  • [22] Energy efficiency and borehole sizing for photovoltaic-thermal collectors integrated to ground source heat pump system: A Nordic case study
    Liravi, Mohammad
    Karkon, Ehsan
    Jamot, Jakob
    Wemhoener, Carsten
    Dai, Yanjun
    Georges, Laurent
    ENERGY CONVERSION AND MANAGEMENT, 2024, 313
  • [23] Performance analysis and optimization of photovoltaic thermal coupled ground source heat pump system
    Wei, Wenqi
    Yue, Han
    Huang, Jiguang
    Zhang, Heng
    Liu, Haowen
    Chen, Haiping
    Cheng, Chao
    ENERGY, 2025, 319
  • [24] Performance enhancement of a photovoltaic thermal (PVT) and ground-source heat pump system
    Abu-Rumman, Mohammad
    Hamdan, Mohammad
    Ayadi, Osama
    GEOTHERMICS, 2020, 85
  • [25] Alternative refrigerants for the heat pump of a ground source heat pump system
    Sagia, Zoi
    Rakopoulos, Constantinos
    APPLIED THERMAL ENGINEERING, 2016, 100 : 768 - 774
  • [26] Optimization of an integrated system including a photovoltaic/thermal system and a ground source heat pump system for building energy supply in cold areas
    Qiu, Guodong
    Li, Kuangfu
    Cai, Weihua
    Yu, Shipeng
    APPLIED ENERGY, 2023, 349
  • [27] Feasibility study on two schemes for alleviating the underground heat accumulation of the ground source heat pump
    Zhou, Shiyu
    Cui, Wenzhi
    Li, Zhisong
    Liu, Xianyan
    SUSTAINABLE CITIES AND SOCIETY, 2016, 24 : 1 - 9
  • [28] Dynamic simulation analysis of ground source heat pump system based on photovoltaic power waste heat
    Yang X.
    Niu S.
    Mao H.
    Shi G.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (10): : 341 - 348
  • [29] Study on Solar Energy - Ground Source Heat Pump Application in Changchun
    Ran, Chunyu
    Yan, Bojiao
    RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 1506 - 1509
  • [30] Economic feasibility of ground source heat pump system deployed in expressway service area