Fast field echo resembling CT using restricted echo-spacing (FRACTURE) MR sequence can provide craniocervical region images comparable to a CT in dogs

被引:1
|
作者
Lee, Dongjae [1 ]
Kim, Eunjee [1 ]
Woo, Hyeonjae [1 ]
Jeon, Chang-Yeop [2 ]
Yoon, Junghee [1 ]
Choi, Jihye [1 ]
机构
[1] Seoul Natl Univ, Coll Vet Med, Dept Vet Med Imaging, Seoul, South Korea
[2] Korea Res Inst Biosci & Biotechnol, Natl Primate Res Ctr, Cheongju, South Korea
基金
新加坡国家研究基金会;
关键词
bone; canine; CT-like; MRI; vertebra; KING CHARLES SPANIELS; 3-DIMENSIONAL COMPUTED-TOMOGRAPHY; CHIARI-LIKE MALFORMATION; CAUDAL CRANIAL FOSSA; MORPHOMETRIC-ANALYSIS; BASILAR INVAGINATION; FEATURES; TIME;
D O I
10.3389/fbioe.2024.1297675
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Magnetic resonance imaging (MRI) is essential for evaluating cerebellar compression in patients with craniocervical junction abnormalities (CJA). However, it is limited in depicting cortical bone because of its short T2 relaxation times, low proton density, and organized structure. Fast field echo resembling a computed tomography (CT) scan using restricted echo-spacing (FRACTURE) MRI, is a new technique that offers CT-like bone contrast without radiation. This study aimed to assess the feasibility of using FRACTURE MRI for craniocervical junction (CCJ) assessment compared with CT and conventional MRI, potentially reducing the need for multiple scans and radiation exposure, and simplifying procedures in veterinary medicine. CT and MRI of the CCJ were obtained from five healthy beagles. MRI was performed using three-dimensional (3D) T1-weighted, T2-weighted, proton density-weighted (PDW), single echo-FRACTURE (sFRACTURE), and multiple echo-FRACTURE (mFRACTURE) sequences. For qualitative assessment, cortical delineation, trabecular bone visibility, joint space visibility, vertebral canal definition, overall quality, and artifacts were evaluated for each sequence. The geometrical accuracy, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were quantified. Both sFRACTURE and CT images provided significantly higher scores for cortical delineation and trabecular bone visibility than conventional MRI. Joint space visibility and vertebral canal definition were similar to those observed on CT images, regardless of the MR sequence. In the quantitative assessment, the distances measured on T2-weighted images differed significantly from those measured on CT. There were no significant differences between the distances taken using T1-weighted, PD-weighted, sFRACTURE, mFRACTURE and those taken using CT. T1-weighted and sFRACTURE had a higher SNR for trabecular bone than CT. The CNR between the cortical bone and muscle was high on CT and FRACTURE images. However, the CNR between the cortical and trabecular bones was low in mFRACTURE. Similar to CT, FRACTURE sequences showed higher cortical delineation and trabecular bone visibility than T2-weighted, T1-weighted, and PDW CCJ sequences. In particular, sFRACTURE provided a high signal-to-noise ratio (SNR) of the trabecular bone and a high CNR between the cortical bone and muscle and between the cortical and trabecular bones. FRACTURE sequences can complement conventional MR sequences for bone assessment of the CCJ in dogs.
引用
收藏
页数:14
相关论文
共 9 条
  • [1] Fast field echo resembling a CT using restricted echo-spacing (FRACTURE) sequence for shoulder joint in normal dogs
    Ryu, Sanghwa
    Park, Soomin
    Kim, Eunjee
    Woo, Hyeonjae
    Jeon, Chang-yeop
    Yoon, Junghee
    Choi, Jihye
    FRONTIERS IN VETERINARY SCIENCE, 2024, 11
  • [2] Fast field echo resembling a CT using restricted echo-spacing (FRACTURE): a novel MRI technique with superior bone contrast
    Johnson, Brian
    Alizai, Hamza
    Dempsey, Molly
    SKELETAL RADIOLOGY, 2021, 50 (08) : 1705 - 1713
  • [3] Fast field echo resembling a CT using restricted echo-spacing (FRACTURE): a novel MRI technique with superior bone contrast
    Brian Johnson
    Hamza Alizai
    Molly Dempsey
    Skeletal Radiology, 2021, 50 : 1705 - 1713
  • [4] Assessment of proximal tibial fractures with 3D FRACTURE (fast field echo resembling a CT using restricted echo-spacing) MRI-intra-individual comparison with CT
    Ristow, Inka
    Zhang, Shuo
    Riedel, Christoph
    Lenz, Alexander
    Akoto, Ralph
    Krause, Matthias
    Adam, Gerhard
    Bannas, Peter
    Henes, Frank Oliver
    Well, Lennart
    EUROPEAN RADIOLOGY, 2025,
  • [5] Bone injury imaging in knee and ankle joints using fast-field-echo resembling a CT using restricted echo-spacing MRI: a feasibility study
    Wang, Nan
    Jin, Zhengshi
    Liu, Funing
    Chen, Lihua
    Zhao, Ying
    Lin, Liangjie
    Liu, Ailian
    Song, Qingwei
    FRONTIERS IN ENDOCRINOLOGY, 2024, 15
  • [6] Added value of ultra-short echo time and fast field echo using restricted echo-spacing MR imaging in the assessment of the osseous cervical spine
    Eva Deininger-Czermak
    Dominic Gascho
    Sabine Franckenberg
    Pascal Kälin
    Christian Blüthgen
    Christina Villefort
    Michael J. Thali
    Roman Guggenberger
    La radiologia medica, 2023, 128 : 234 - 241
  • [7] Added value of ultra-short echo time and fast field echo using restricted echo-spacing MR imaging in the assessment of the osseous cervical spine
    Deininger-Czermak, Eva
    Gascho, Dominic
    Franckenberg, Sabine
    Kalin, Pascal
    Bluthgen, Christian
    Villefort, Christina
    Thali, Michael J.
    Guggenberger, Roman
    RADIOLOGIA MEDICA, 2023, 128 (02): : 234 - 241
  • [8] Three-Dimensional Magnetic Resonance Imaging Fast Field Echo Resembling a Computed Tomography Using Restricted Echo-Spacing Sequence Is Equivalent to 3-Dimensional Computed Tomography in Quantifying Bone Loss and Measuring Shoulder Morphology in Patients With Shoulder Dislocation
    Cui, De-Dong
    Long, Yi
    Yan, Yan
    Li, Cheng
    Yang, Yi-Tao
    Zhong, Jing-Lian
    Yang, Rui
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (06): : 1777 - 1788
  • [9] Unenhanced ECG-Gated Fast Spin-Echo MR Digital Subtraction Angiography (MRDSA) Using Short Echo-Spacing Three-Dimensional Sequence of Femoral Arteries: Initial Experience
    Morita, Satoru
    Kojima, Shinya
    Hirata, Masami
    Suzuki, Masaru
    Suzuki, Kazufumi
    Masukawa, Ai
    Ueno, Eiko
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (01) : 157 - 164