Bone injury imaging in knee and ankle joints using fast-field-echo resembling a CT using restricted echo-spacing MRI: a feasibility study

被引:0
|
作者
Wang, Nan [1 ]
Jin, Zhengshi [1 ]
Liu, Funing [1 ]
Chen, Lihua [1 ]
Zhao, Ying [1 ]
Lin, Liangjie [2 ]
Liu, Ailian [1 ]
Song, Qingwei [1 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Dalian, Peoples R China
[2] Philips Healthcare, Clin & Tech Support, Beijing, Peoples R China
来源
关键词
MRI; CT; bone; knee; ankle; SYNTHETIC CT; TIME UTE; SEQUENCE;
D O I
10.3389/fendo.2024.1421876
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To explore the consistency of FRACTURE (Fast-field-echo Resembling A CT Using Restricted Echo-spacing) MRI and X-Ray/computerized tomography (CT) in the evaluation of bone injuries in knee and ankle joints.Methods From Nov. 2020 to Jul. 2023, 42 patients with knee joint or ankle joint injuries who underwent FRACTURE MRI examinations were retrospectively collected. 11 patients were examined by both X-Ray and FRACTURE examinations. 31 patients were examined by both CT and FRACTURE examinations. The fracture, osteophyte, and bone destruction of the joints were evaluated by two radiologists using X-Ray/CT and FRACTURE images, respectively. Kappa test was used for consistency analysis.Results The evaluation consistency of fracture, osteophyte and bone destruction via X-Ray and FRACTURE images by radiologist 1 were 0.879, 0.867 and 0.847 respectively, and for radiologist 2 were 0.899, 0.930, and 0.879, respectively. The evaluation consistency of fracture, osteophyte and bone destruction via CT and FRACTURE images by radiologist 1 were 0.938, 0.937 and 0.868 respectively, and for radiologist 2 were 0.961, 0.930, and 0.818, respectively.Conclusion For fracture, osteophyte, and bone destruction of knee and ankle joints. FRACTURE MRI showed a high consistency with X-Ray/CT examinations.
引用
收藏
页数:9
相关论文
共 19 条
  • [1] Fast field echo resembling a CT using restricted echo-spacing (FRACTURE): a novel MRI technique with superior bone contrast
    Johnson, Brian
    Alizai, Hamza
    Dempsey, Molly
    SKELETAL RADIOLOGY, 2021, 50 (08) : 1705 - 1713
  • [2] Fast field echo resembling a CT using restricted echo-spacing (FRACTURE): a novel MRI technique with superior bone contrast
    Brian Johnson
    Hamza Alizai
    Molly Dempsey
    Skeletal Radiology, 2021, 50 : 1705 - 1713
  • [3] Fast field echo resembling a CT using restricted echo-spacing (FRACTURE) sequence for shoulder joint in normal dogs
    Ryu, Sanghwa
    Park, Soomin
    Kim, Eunjee
    Woo, Hyeonjae
    Jeon, Chang-yeop
    Yoon, Junghee
    Choi, Jihye
    FRONTIERS IN VETERINARY SCIENCE, 2024, 11
  • [4] Fast field echo resembling CT using restricted echo-spacing (FRACTURE) MR sequence can provide craniocervical region images comparable to a CT in dogs
    Lee, Dongjae
    Kim, Eunjee
    Woo, Hyeonjae
    Jeon, Chang-Yeop
    Yoon, Junghee
    Choi, Jihye
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [5] Assessment of proximal tibial fractures with 3D FRACTURE (fast field echo resembling a CT using restricted echo-spacing) MRI-intra-individual comparison with CT
    Ristow, Inka
    Zhang, Shuo
    Riedel, Christoph
    Lenz, Alexander
    Akoto, Ralph
    Krause, Matthias
    Adam, Gerhard
    Bannas, Peter
    Henes, Frank Oliver
    Well, Lennart
    EUROPEAN RADIOLOGY, 2025,
  • [6] Added value of ultra-short echo time and fast field echo using restricted echo-spacing MR imaging in the assessment of the osseous cervical spine
    Eva Deininger-Czermak
    Dominic Gascho
    Sabine Franckenberg
    Pascal Kälin
    Christian Blüthgen
    Christina Villefort
    Michael J. Thali
    Roman Guggenberger
    La radiologia medica, 2023, 128 : 234 - 241
  • [7] Added value of ultra-short echo time and fast field echo using restricted echo-spacing MR imaging in the assessment of the osseous cervical spine
    Deininger-Czermak, Eva
    Gascho, Dominic
    Franckenberg, Sabine
    Kalin, Pascal
    Bluthgen, Christian
    Villefort, Christina
    Thali, Michael J.
    Guggenberger, Roman
    RADIOLOGIA MEDICA, 2023, 128 (02): : 234 - 241
  • [8] Three-Dimensional Magnetic Resonance Imaging Fast Field Echo Resembling a Computed Tomography Using Restricted Echo-Spacing Sequence Is Equivalent to 3-Dimensional Computed Tomography in Quantifying Bone Loss and Measuring Shoulder Morphology in Patients With Shoulder Dislocation
    Cui, De-Dong
    Long, Yi
    Yan, Yan
    Li, Cheng
    Yang, Yi-Tao
    Zhong, Jing-Lian
    Yang, Rui
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (06): : 1777 - 1788
  • [9] Bone Imaging of the Knee Using Short-Interval Delta Ultrashort Echo Time and Field Echo Imaging
    Bae, Won C.
    Malis, Vadim
    Yamashita, Yuichi
    Mesa, Anya
    Vucevic, Diana
    Miyazaki, Mitsue
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (16)
  • [10] Is simultaneous multisection turbo spin echo ready for clinical MRI? A feasibility study on fast imaging of knee lesions
    Li, X.
    Peng, Z.
    Sun, Y.
    Cui, J.
    CLINICAL RADIOLOGY, 2020, 75 (03) : 238.e21 - 238.e30