A quantitative framework for patient-specific collision detection in proton therapy

被引:0
|
作者
Northway, Stephen K. [1 ,2 ]
Vallejo, Bailey M. [1 ,2 ]
Liu, Lawrence [1 ,2 ]
Hansen, Emily E. [1 ,2 ]
Tang, Shikui [3 ]
Mah, Dennis [4 ]
Macewan, Iain J. [1 ,2 ]
Urbanic, James J. [1 ,2 ]
Chang, Chang [1 ,2 ,5 ]
机构
[1] Univ Calif San Diego, Dept Radiat Med & Appl Sci, La Jolla, CA USA
[2] Calif Protons Canc Therapy Ctr, San Diego, CA USA
[3] Texas Ctr Proton Therapy, Irving, TX USA
[4] Procure Proton Therapy Ctr, Somerset, NJ USA
[5] Univ Calif San Diego, Dept Radiat Med & Appl Sci, 9730 Summers Ridge Rd, San Diego, CA 92121 USA
来源
关键词
collision detection; lateral penumbra; proton therapy; GAUSSIAN-BEAM MODEL; AVOIDANCE; PREDICTION; SIMULATION; PREVENTION; SCATTERING; SOFTWARE;
D O I
10.1002/acm2.14247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundBeam modifying accessories for proton therapy often need to be placed in close proximity of the patient for optimal dosimetry. However, proton treatment units are larger in size and as a result the planned treatment geometry may not be achievable due to collisions with the patient. A framework that can accurately simulate proton treatment geometry is desired.PurposeA quantitative framework was developed to model patient-specific proton treatment geometry, minimize air gap, and avoid collisions.MethodsThe patient's external contour is converted into the International Electrotechnique Commission (IEC) gantry coordinates following the patient's orientation and each beam's gantry and table angles. All snout components are modeled by three-dimensional (3D) geometric shapes such as columns, cuboids, and frustums. Beam-specific parameters such as isocenter coordinates, snout type and extension are used to determine if any point on the external contour protrudes into the various snout components. A 3D graphical user interface is also provided to the planner to visualize the treatment geometry. In case of a collision, the framework's analytic algorithm quantifies the maximum protrusion of the external contour into the snout components. Without a collision, the framework quantifies the minimum distance of the external contour from the snout components and renders a warning if such distance is less than 5 cm.ResultsThree different snout designs are modeled. Examples of potential collision and its aversion by snout retraction are demonstrated. Different patient orientations, including a sitting treatment position, as well as treatment plans with multiple isocenters, are successfully modeled in the framework. Finally, the dosimetric advantage of reduced air gap enabled by this framework is demonstrated by comparing plans with standard and reduced air gaps.ConclusionImplementation of this framework reduces incidence of collisions in the treatment room. In addition, it enables the planners to minimize the air gap and achieve better plan dosimetry.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] A Patient-Specific Computational Framework for the Argus II Implant
    Finn, Kathleen E.
    Zander, Hans J.
    Graham, Robert D.
    Lempka, Scott F.
    Weiland, James D.
    IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY, 2020, 1 : 190 - 196
  • [42] The case for patient-specific dosimetry in radionuclide therapy
    Stabin, Michael G.
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2008, 23 (03) : 273 - 284
  • [43] Improved patient-specific optimization of the stopping power calibration for proton therapy planning using a single optimized proton radiography
    Krah, N.
    Testa, M.
    Rinaldi, I.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S62 - S63
  • [44] A parameter estimation framework for patient-specific hemodynamic computations
    Itu, Lucian
    Sharma, Puneet
    Passerini, Tiziano
    Kamen, Ali
    Suciu, Constantin
    Comaniciu, Dorin
    JOURNAL OF COMPUTATIONAL PHYSICS, 2015, 281 : 316 - 333
  • [45] A framework for analytical estimation of patient-specific CT dose
    Youn, Hanbean
    Kim, Jin Woo
    Jeon, Hosang
    Nam, Jiho
    Yun, Seungman
    Cho, Min Kook
    Kim, Ho Kyung
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [46] A Computational Framework for Patient-Specific Dose Agreement Verification in CBCT-Guided Radiation Therapy
    Xia, R.
    Zhang, R.
    Yang, M.
    Guo, F.
    Tang, M.
    Zhou, L.
    Liu, M.
    Yin, F. F.
    Chen, M.
    Yang, Z.
    MEDICAL PHYSICS, 2024, 51 (10) : 7724 - 7725
  • [47] A Working TTFields Therapy Framework for Patient-Specific Segmentation-Based Treatment Planning and Dosimetry
    Stepovoy, K.
    Vardi, M.
    Zigelman, G.
    Urman, N.
    Naveh, A.
    Shapira, N.
    Berger, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E721 - E721
  • [48] Utility of a patient-specific aperture collimator and multi-leaf collimator in line scanning proton therapy
    Ko, Mincheol
    Jeon, Chanil
    Ahn, Sung Hwan
    Han, Youngyih
    Chung, Kwangzoo
    Cho, Sungkoo
    Jo, Kwanghyun
    Shin, Eun Hyuk
    Lee, Sehyoung
    Lee, Woojin
    Oh, Yoonjin
    Kim, Juhye
    Kang, Seokyoon
    Park, Hee Chul
    Lee, Kisung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 85 (09) : 751 - 762
  • [49] A 3D polymer gel dosimeter coupled to a patient-specific anthropomorphic phantom for proton therapy
    Hillbrand, M.
    Landry, G.
    Dedes, G.
    Pappas, E. P.
    Kalaitzakis, G.
    Kurz, C.
    Doerringer, F.
    Kaiser, K.
    Wuerl, M.
    Englbrecht, F.
    Dietrich, O.
    Makris, D.
    Pappas, E.
    Parodi, K.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S432 - S433
  • [50] Use of treatment log files in spot scanning proton therapy as part of patient-specific quality assurance
    Li, Heng
    Sahoo, Narayan
    Poenisch, Falk
    Suzuki, Kazumichi
    Li, Yupeng
    Li, Xiaoqiang
    Zhang, Xiaodong
    Lee, Andrew K.
    Gillin, Michael T.
    Zhu, X. Ronald
    MEDICAL PHYSICS, 2013, 40 (02)