Numerical simulation of laterite confined masonry building subjected to quasi-static monotonic lateral loading

被引:3
|
作者
Chourasia, Ajay [1 ]
Singhal, Shubham [2 ]
Chourasia, Akshat [3 ]
机构
[1] CSIR Cent Bldg Res Inst, Struct Engn Div, Roorkee, India
[2] Amity Univ, Amity Sch Engn & Technol, Noida, India
[3] Manipal Inst Technol, Dept Civil Engn, Manipal, India
关键词
Laterite blocks; confined masonry; stress analysis; seismic response; seismic parameters; PERFORMANCE; BEHAVIOR; STONES; WALLS; INDIA;
D O I
10.1080/24705314.2022.2142895
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper attempts to establish a relationship between strength of laterite units and mortar to predict masonry strength and elastic modulus of laterite masonry based on material properties reported in literature. The properties obtained from derived analytical models were used as input parameters for finite element analysis (FEA) of laterite confined masonry (LCM) buildings under quasi-static loading. Numerical studies were performed on LCM buildings up to four stories to study seismic behaviour. LCM buildings upto three storeys demonstrated stresses within the permissible limits for the wall thickness of 150 mm, while four storey LCM building showed high stress concentration exceeding the permissible limits, for which ground storey wall thickness may be increased to 300 mm. One storey LCM building resisted lateral load equivalent to 1.02 g of its mass, while the corresponding values for two, three and four storey LCM buildings were 0.40 g, 0.23 g and 0.13 g, respectively. LCM buildings up to three storey demonstrated maximum damage index in the range of 0.8 to 0.85, indicating collapse prevention state. Howbeit, four storey LCM building exhibited damage index of 0.91 at maximum displacement, which corresponds to collapse state.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [31] On crushing behavior of square aluminum/CFRP hybrid structures subjected to quasi-static loading
    Zhu, Guohua
    Zhao, Zhonghao
    Cao, Xi-Ao
    Wei, Lulu
    Wang, Zhen
    Zhao, Xuan
    THIN-WALLED STRUCTURES, 2023, 184
  • [32] The rate dependent response of a titanium alloy subjected to quasi-static loading in ambient environment
    W. Zhou
    K. G. Chew
    Journal of Materials Science, 2002, 37 : 5159 - 5165
  • [33] Effect of indenter displacement onangle plied composite plates subjected to quasi-static loading
    Kumar, M. Ashok
    Prasad, A. M. K.
    Ravishankar, D. V.
    Sateesh, N.
    Ravi, D.
    MATERIALS TODAY-PROCEEDINGS, 2015, 2 (4-5) : 2938 - 2943
  • [34] Experimental and numerical analysis of slotted tube systems under quasi-static loading
    Morris, Edmund
    Olabi, A.G.
    Hashmi, M. Saleem J.
    International Journal of Computational Materials Science and Surface Engineering, 2009, 2 (1-2) : 137 - 145
  • [35] Experimental and numerical assessment of oblique loading quasi-static testing of railway anticlimbers
    Moreno, C.
    Reid, S.
    Williams, T.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART F-JOURNAL OF RAIL AND RAPID TRANSIT, 2021, 235 (02) : 143 - 154
  • [36] Bidirectionally graded honeycombs under quasi-static loading: Experimental and numerical study
    Ahmed, Mohammad Faisal
    Granville, William
    MATERIALS TODAY COMMUNICATIONS, 2024, 41
  • [37] Numerical Simulation Study on Quasi-static fracture problem of implicit methods
    Yu, Qi-ming
    Chen, Yuyang
    Zhang, Zhi
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 3683 - 3686
  • [38] Three-dimensional numerical simulation of quasi-static pebble flow
    Sun, X. M.
    Dong, Y. J.
    Hao, P. F.
    Shi, L.
    Li, F.
    Feng, Y. T.
    ADVANCED POWDER TECHNOLOGY, 2017, 28 (02) : 499 - 505
  • [39] From Quasi-static to High Frequencies : An Overview of Numerical Simulation at EADS
    Sylvand, Guillaume
    SCIENTIFIC COMPUTING IN ELECTRICAL ENGINEERING (SCEE 2010), 2012, 16 : 81 - 85
  • [40] Numerical simulation of soft brick unreinforced masonry walls subjected to lateral loads
    Vemuri, Jayaprakash
    Ehteshamuddin, Syed
    Kolluru, Subramaniam
    COGENT ENGINEERING, 2018, 5 (01): : 1 - 21