Characterising the Pelletron beam at the University of Melbourne

被引:1
|
作者
Steinberg, A. F. [1 ,2 ,3 ]
Yap, J. S. L.
Norman, H. X. Q.
Appleby, R. B. [2 ,3 ]
Sheehy, S. L. [4 ]
机构
[1] Univ Melbourne, Grattan St, Parkville, Vic 3010, Australia
[2] Univ Manchester, Oxford Rd, Manchester M13 9PL, England
[3] Cockcroft Inst, Keckwick Lane, Daresbury WA4 4AD, England
[4] ANSTO, New Illawarra Rd, Lucas Heights, NSW 2234, Australia
关键词
Pelletron; Current; Phase space; Measurement; Proton beam; FARADAY CUP; ION-SOURCE; ACCELERATOR; BRIGHTNESS; TANDEM;
D O I
10.1016/j.nima.2023.169013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Pelletron at the University of Melbourne is a DC particle accelerator that has been used for materials analysis and ion implantation since its installation in the 1970s. Today, it is primarily used to produce proton and helium beams up to 3.5 MeV and 1.5 MeV respectively, for three beamlines with a range of different experiments. The beam stability and fundamental beam parameters such as the transverse phase space distribution and emittance have not been previously investigated in detail. We have performed systematic measurements to determine the beam current variation, finding persistent fluctuations: our study determined that internal wire scanners used for monitoring the beam profile contribute to a periodic current drop. We also found that large terminal voltage oscillations reduce the average current. In addition, the phase space has been measured using a custom-built slit-grid apparatus. We found that the Courant-Snyder (Twiss) parameters are a function of the operational characteristics of the Pelletron, with the emittance more than doubling between measurements. To parametrise the beam despite the fluctuations, we introduce a 'minimum bounding ellipse' described by a set of Courant-Snyder parameters that is representative of the beam characteristics for all the measurements: for our data, this has beta = 8.2(5) m, alpha =-5.2(3), and an emittance of 0.34(3) mmmrad. These parameters will enable future beamline design in Melbourne, and give an indication for the requirements at other Pelletron facilities. Our characterisation techniques can provide a low-cost method to probe beam parameters for improvements in the operation and efficiency of similar DC accelerators, allowing for more accurate measurements and reduced data acquisition times.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Demonstrating the melbourne university respirator
    Dean, Katrina
    AUSTRALIAN JOURNAL OF POLITICS AND HISTORY, 2007, 53 (03): : 392 - 406
  • [22] THE TARGET LABORATORY OF THE PELLETRON ACCELERATOR AT THE UNIVERSITY-OF-SAO-PAULO
    UETA, N
    ENGEL, WGP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 282 (01): : 188 - 190
  • [23] Development of a multimodal ion-beam-analysis system for the 1-MV tandem Pelletron accelerator installed at Tohoku University
    Maruta, Kyoka
    Toyama, Sho
    Miwa, Misako
    Takamura, Hitoshi
    Ishii, Akihiro
    Kada, Wataru
    Kikuchi, Yohei
    Matsuyama, Shigeo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2024, 554
  • [24] 14UD PELLETRON ACCELERATOR AT AUSTRALIAN-NATIONAL-UNIVERSITY
    OPHEL, TR
    HARRISON, JS
    NEWTON, JO
    SPEAR, RH
    TITTERTON, EW
    WEISSER, DC
    NUCLEAR INSTRUMENTS & METHODS, 1974, 122 (1-2): : 227 - 234
  • [25] Protective structures research at the University of Melbourne
    Ngo, T.
    Lumantarna, R.
    Mendis, P.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2012, 13 (01) : 43 - 63
  • [26] Protective structures research at the university of Melbourne
    Lumantarna, Raymond, 1600, Taylor and Francis Ltd. (13):
  • [27] Installation of ion implantation beam line for 3 MV Tandem Pelletron
    Poudel, P. R.
    Mitchell, L. J.
    Smith, E. B.
    Phinney, L. C.
    Hossain, K.
    Burns, L. R.
    Weathers, D. L.
    Duggan, J. L.
    McDaniel, F. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2): : 627 - 629
  • [28] FOUNDATION OF MEDICAL SCHOOL OF UNIVERSITY OF MELBOURNE
    RUSSELL, KF
    MEDICAL JOURNAL OF AUSTRALIA, 1962, 2 (06) : 228 - &
  • [29] The University of Melbourne: Practical loyalty.
    Berry, RJA
    LANCET, 1915, 1 : 1368 - 1369
  • [30] MEMORIES OF MELBOURNE UNIVERSITY - DOW,H
    MACINTYRE, S
    OVERLAND, 1984, (96): : 61 - 63