A passive membrane system for on-line mass spectrometry reagent addition

被引:1
|
作者
Zarkovic, Taelor M. [1 ,2 ]
Borden, Scott A. [1 ,2 ]
Krogh, Erik T. [1 ,2 ]
Gill, Chris G. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Vancouver Isl Univ, Dept Chem, Appl Environm Res Labs, Nanaimo, BC, Canada
[2] Univ Victoria, Dept Chem, Victoria, BC, Canada
[3] Simon Fraser Univ, Dept Chem, Burnaby, BC, Canada
[4] Univ Washington, Dept Environm & Occupat Hlth Sci, Seattle, WA USA
[5] Vancouver Isl Univ, Dept Chem, Appl Environm Res Labs AERL, 900 Fifth St, Nanaimo, BC V9R 5S5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; POST COLUMN DERIVATIZATION; LIQUID-CHROMATOGRAPHY; ELECTROSPRAY-IONIZATION; POSTCOLUMN ADDITION; ION CHROMATOGRAPHY; ORGANIC-COMPOUNDS; QUANTITATION; SUPPRESSION; ACID;
D O I
10.1002/rcm.9487
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationalePost-separation addition of chemical modifiers in liquid chromatography-mass spectrometry is widely used for improving ionization sensitivity and selectivity. This is typically accomplished using a post-column T-junction, which can result in sample dilution and imperfect mixing. We present a passive semi-permeable hollow fiber membrane approach for the addition of chemical modifiers that avoids these issues. MethodsModel compounds were directly infused by flow injection to an electrospray ionization triple quadrupole mass spectrometer after passing through a polydimethylsiloxane hollow fiber membrane. Ionization enhancement reagents were introduced into the flowing stream by membrane permeation from aqueous solutions. Ionization enhancement from volatile acids and bases in positive and negative electrospray ionization was evaluated to assess the feasibility of this approach. ResultsThe membrane-based apparatus resulted in relative ionization enhancement factors of up to 14x, depending upon the analyte, reagent, and ionization mode used. Ionization enhancement signal stability is reasonable (relative standard deviation of 5-7%) for extended periods from the same reagent solution, and minimal analyte dilution is observed. A proof-of-concept demonstration of the chromatographic "trifluoroacetic acid fix" strategy is presented. ConclusionsAn on-line mass spectrometry ionization reagent addition method with potential post-chromatography reagent addition applications was developed using a hollow fiber polydimethylsiloxane membrane. This approach offers a promising alternative to traditional methods requiring additional hardware such as pumps and T-junctions that can result in sample dilution and imperfect reagent mixing.