Separation of volatile organic contaminants from water using a direct-contact dehumidifier: An experimental study and modeling

被引:1
|
作者
Nikooei, Elnaz [1 ]
AuYeung, Nick [2 ]
Lima, Iolar [2 ]
Tan, Xu [3 ]
Benard, Andre [3 ]
Abbasi, Bahman [1 ]
机构
[1] Oregon State Univ, Sch Mech Ind & Mfg Engn, Corvallis, OR 97331 USA
[2] Oregon State Univ, Sch Chem Biol & Environm Engn, Corvallis, OR 97331 USA
[3] Michigan State Univ, Dept Mech Engn, E Lansing, MI 48824 USA
关键词
Water treatment; Dehumidification; Direct contact; Packed column; Heat and mass transfer; WASTE-WATER; NONCONDENSABLE GAS; SIMPLEX-METHOD; CONDENSATION; DISPOSAL; HYDROCARBON; EXTRACTION; OIL;
D O I
10.1016/j.jwpe.2023.103520
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A packed-bed, direct-contact dehumidifier (PB-DCD) has been developed to selectively condense water from a gaseous mixture of organic contaminants. In this process, hot air is humidified by mixing with wastewater vapor in a static mixer and is dehumidified by subcooled fresh water passing through the PB-DCD in a counter-current configuration. The goal of this study is to understand the relationship between various operating parameters and how they affect separation of isopropyl alcohol (IPA) from the gaseous mixture with the purpose of expanding the investigation to other contaminants in the future. The process has been successfully used to separate IPA from wastewater. Different parameters including the concentration of IPA in water, feed temperature, air-to-vapor ratio, and cooling-water-to-vapor mass ratio, as well as residence time were examined to determine their in-fluence on contaminant separation and clean water recovery rate. The Buckingham Pi theorem was applied to reduce the number of studying variables by generating non-dimensional groups. Experiments were performed to determine the relationship between the non-dimensional parameters and model mass transfer in the system. Mass transfer coefficients for multicomponent gaseous mixture condensation in a packed-bed direct contact condenser column are calculated and a modified correlation of mass transfer is developed. The parameters of the mass transfer model are obtained from operating conditions of the PB-DCD, stream conditions and thermodynamic properties. A modified Sherwood correlation is developed to predict IPA separation from a gaseous mixture consisting of air, water, and IPA. The modified Sherwood correlation is applied to successfully predict the Sherwood number with a mean absolute error equal to 6.6 %. According to the experimental results, the maximum IPA separation achieved was 76.3 %, which corresponds to a water recovery rate of 58.7 %.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Impact of Atmospheric Pressure Fluctuations on Nonequilibrium Transport of Volatile Organic Contaminants in the Vadose Zone: Experimental and Numerical Modeling
    Qi, Shengqi
    Wang, Yidong
    Wang, Liuwei
    Luo, Jian
    Hou, Deyi
    WATER RESOURCES RESEARCH, 2021, 57 (08)
  • [42] Modeling of volatile organic compounds removal from water by pervaporation process
    Ghoreyshi, A. A.
    Jahanshahi, M.
    Peyvandi, K.
    DESALINATION, 2008, 222 (1-3) : 410 - 418
  • [43] The effect of concentration polarization on the separation of volatile organic compounds from water by pervaporation
    Baker, RW
    Wijmans, JG
    Athayde, AL
    Daniels, R
    Ly, JH
    Le, M
    JOURNAL OF MEMBRANE SCIENCE, 1997, 137 (1-2) : 159 - 172
  • [44] Surface modification of membranes for the separation of volatile organic compounds from water by pervaporation
    Khayet, M
    Matsuura, T
    DESALINATION, 2002, 148 (1-3) : 31 - 37
  • [45] The effect of concentration polarization on the separation of volatile organic compounds from water by pervaporation
    Memb. Technology and Research, Inc., 1360 Willow Road, Menlo Park, CA 94025, United States
    不详
    不详
    J. Membr. Sci., 1-2 (159-172):
  • [46] Modeling of a direct-contact humidification-dehumidification desalination unit in a 256 MW steam power plant using effluent streams: Case study
    Zamen, Mohammad
    Kahani, Mostafa
    Yazdanpanahi, Javad
    Abedini, Reza
    Ahmadi, Mohammad Hossein
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 45
  • [47] Experimental and modeling approach to study sorption of dissolved hydrophobic organic contaminants to microbial biofilms
    Wicke, Daniel
    Boeckelmann, Uta
    Reemtsma, Thorsten
    WATER RESEARCH, 2007, 41 (10) : 2202 - 2210
  • [48] Experimental Study on Pressure Oscillations of Direct-Contact Condensation between Saturated Steam and Droplets at Sub-Atmospheric Pressure
    Jing, Yuanlin
    Wang, Chenhao
    Huang, Qunwu
    Wang, Yiping
    Yu, Yangyang
    PROCESSES, 2024, 12 (03)
  • [49] Removal of organic contaminants from water using nanosponge cyclodextrin polyurethanes
    Mhlanga, Sabelo D.
    Marnba, Bhekie B.
    Krause, Rui In
    Malefetse, Tshepo J.
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2007, 82 (04) : 382 - 388
  • [50] Removal of organic contaminants from flowback water using Fenton process
    Sinha, Shikha
    Roy, Debashis
    Roy, Omkar
    Neogi, Sudarsan
    De, Sirshendu
    JOURNAL OF WATER PROCESS ENGINEERING, 2022, 47