TROPOMI/S5P Total Column Water Vapor validation against AERONET ground-based measurements

被引:4
|
作者
Garane, Katerina [1 ]
Chan, Ka Lok [2 ,3 ]
Koukouli, Maria-Elissavet [1 ]
Loyola, Diego [2 ]
Balis, Dimitris [1 ]
机构
[1] Aristotle Univ Thessaloniki AUTH, Lab Atmospher Phys LAP, Thessaloniki 54124, Greece
[2] Deutsches Zentrum Luft & Raumfahrt DLR, Inst Method Fernerkundung IMF, D-82234 Oberpfaffenhofen, Germany
[3] Rutherford Appleton Lab Space, Oxford OX11 0QX, Oxon, England
关键词
PRECIPITABLE WATER; SENTINEL-5; PRECURSOR; H2O/HDO COLUMNS; SUN PHOTOMETER; RETRIEVAL; RADIOSONDES; CLIMATE; QUALITY; MISSION; GOME-2;
D O I
10.5194/amt-16-57-2023
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Water vapor plays an important role in the greenhouse effect, rendering it an atmospheric constituent that requires continuous and global monitoring by different types of remote sensing instruments. The TROPOspheric Monitoring Instrument Sentinel-5 Precursor (TROPOMI/S5P) Total Column Water Vapor (TCWV) is a new product retrieved from the visible blue spectral range (435-455 nm), using an algorithm that was originally developed for the GOME-2/MetOp sensors. For the purposes of this work, 2.5 years of continuous satellite observations at high spatial resolution are validated against co-located (in space and in time) precipitable water Level 2.0 (quality-assured) ground-based measurements from the NASA AERONET (AErosol RObotic NETwork). The network uses Cimel Sun photometers located at approximately 1300 stations globally to monitor precipitable water among other products. Based on data availability, 369 of the stations were used in this study. The two datasets, satellite- and ground-based, were co-located, and the relative differences of the comparisons were calculated and statistically analyzed. The Pearson correlation coefficient of the two products is found to be 0.91, and the mean bias of the overall relative percentage differences is of the order of -2.7 %. For the Northern Hemisphere midlatitudes (30-60 & LCIRC; N), where the density of the ground-based stations is high, the mean relative bias was found to be -1.8 %, while in the tropics (& PLUSMN;15 & LCIRC;) the TROPOMI TCWV product has a relative dry bias of up to -10 %. The effect of various algorithm and geophysical parameters, such as air mass factor, solar zenith angle, clouds and albedo, is also presented and discussed. It was found that the cloud properties affect the validation results, leading the TCWV to a dry bias of -20 % for low cloud heights (cloud top pressure (CTP) > 800 hPa). Moreover, cloud albedo introduces a wet bias of 15 % when it is below 0.3 and a dry bias up to -25 % when the clouds are more reflective. Overall, the TROPOMI/S5P TCWV product, on a global scale and for moderate albedo and cloudiness, agrees well at -2.7 & PLUSMN;4.9 % with the AERONET observations but probably within about -8 % to -13 % with respect to the "truth ".
引用
收藏
页码:57 / 74
页数:18
相关论文
共 50 条
  • [41] Evaluation of radiosonde, MODIS-NIR-Clear, and AERONET precipitable water vapor using IGS ground-based GPS measurements over China
    Gui, Ke
    Che, Huizheng
    Chen, Quanliang
    Zeng, Zhaoliang
    Liu, Haizhi
    Wang, Yaqiang
    Zheng, Yu
    Sun, Tianze
    Liao, Tingting
    Wang, Hong
    Zhang, Xiaoye
    ATMOSPHERIC RESEARCH, 2017, 197 : 461 - 473
  • [42] The comparison of IR and MW ground-based measurements of total precipitable water
    Berezin, I. A.
    Virolainen, Ya. A.
    Timofeyev, Yu. M.
    Poberovskii, A. V.
    IZVESTIYA ATMOSPHERIC AND OCEANIC PHYSICS, 2016, 52 (03) : 253 - 256
  • [43] Line parameter validation using ground-based solar occultation measurements: Water vapor-A case study
    Veihelmann, B.
    Maurellis, A. N.
    Smith, K. M.
    Tolchenov, R. N.
    Tennyson, J.
    van der Zande, W. J.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2007, 107 (02): : 349 - 359
  • [44] The comparison of IR and MW ground-based measurements of total precipitable water
    I. A. Berezin
    Ya. A. Virolainen
    Yu. M. Timofeyev
    A. V. Poberovskii
    Izvestiya, Atmospheric and Oceanic Physics, 2016, 52 : 253 - 256
  • [45] MICROWAVE GROUND-BASED MEASUREMENTS OF ATMOSPHERIC TOTAL WATER-CONTENT
    SHCHUKIN, GG
    BOBYLEV, LP
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1977, 58 (08): : 801 - 801
  • [46] Comparison of OMI-DOAS total ozone column with ground-based measurements in Argentina
    Orte, P. F.
    Luccini, E.
    Wolfram, E.
    Nollas, F.
    Pallotta, J.
    D'Elia, R.
    Carbajal, G.
    Mbatha, N.
    Hlongwane, N.
    REVISTA DE TELEDETECCION, 2020, (57): : 13 - 23
  • [47] Extended aerosol and surface characterization from S5P/TROPOMI with GRASP algorithm. Part II: Global validation and Intercomparison
    Chen, Cheng
    Litvinov, Pavel
    Dubovik, Oleg
    Bindreiter, Lukas
    Matar, Christian
    Fuertes, David
    Lopatin, Anton
    Lapyonok, Tatyana
    Lanzinger, Verena
    Hangler, Andreas
    Aspetsberger, Michael
    de Graaf, Martin
    Tilstra, Lieuwe Gijsbert
    Stammes, Piet
    Dandocsi, Alexandru
    Gasbarra, Daniele
    Fluck, Elody
    Zehner, Claus
    Retscher, Christian
    REMOTE SENSING OF ENVIRONMENT, 2024, 313
  • [48] Ground-Based GPS Measurements of Precipitable Water Vapor and Their Usefulness for Hydrological Applications
    Bordi, Isabella
    Raziei, Tayeb
    Pereira, Luis Santos
    Sutera, Alfonso
    WATER RESOURCES MANAGEMENT, 2015, 29 (02) : 471 - 486
  • [49] Ground-based measurements of mesospheric water vapor with 13.7 m radio telescope
    Zhou, YL
    Zeng, Q
    Pei, LB
    Yang, GP
    Liu, CS
    CHINESE SCIENCE BULLETIN, 1995, 40 (22): : 1899 - 1902
  • [50] Ground-based measurements of mesospheric water vapor with 13.7 m radio telescope
    Zhou, Y.
    Zeng, Q.
    Pei, L. et al.
    Chinese Science Bulletin, 40 (22):