Where to mount the IMU? Validation of joint angle kinematics and sensor selection for activities of daily living

被引:1
|
作者
Uhlenberg, Lena [1 ,2 ]
Amft, Oliver [1 ,2 ]
机构
[1] Hahn Schickard, Freiburg, Germany
[2] Univ Freiburg, Intelligent Embedded Syst Lab, Freiburg, Germany
来源
关键词
framework validation; joint kinematics; multiscale modeling; sensor selection; wearable inertial sensors; ANATOMY; FILTER;
D O I
10.3389/fcomp.2024.1347424
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We validate the OpenSense framework for IMU-based joint angle estimation and furthermore analyze the framework's ability for sensor selection and optimal positioning during activities of daily living (ADL). Personalized musculoskeletal models were created from anthropometric data of 19 participants. Quaternion coordinates were derived from measured IMU data and served as input to the simulation framework. Six ADLs, involving upper and lower limbs were measured and a total of 26 angles analyzed. We compared the joint kinematics of IMU-based simulations with those of optical marker-based simulations for most important angles per ADL. Additionally, we analyze the influence of sensor count on estimation performance and deviations between joint angles, and derive the best sensor combinations. We report differences in functional range of motion (fRoMD) estimation performance. Results for IMU-based simulations showed MAD, RMSE, and fRoMD of 4.8 degrees, 6.6 degrees, 7.2 degrees for lower limbs and for lower limbs and 9.2 degrees, 11.4 degrees, 13.8 degrees for upper limbs depending on the ADL. Overall, sagittal plane movements (flexion/extension) showed lower median MAD, RMSE, and fRoMD compared to transversal and frontal plane movements (rotations, adduction/abduction). Analysis of sensor selection showed that after three sensors for the lower limbs and four sensors for the complex shoulder joint, the estimation error decreased only marginally. Global optimum (lowest RMSE) was obtained for five to eight sensors depending on the joint angle across all ADLs. The sensor combinations with the minimum count were a subset of the most frequent sensor combinations within a narrowed search space of the 5% lowest error range across all ADLs and participants. Smallest errors were on average < 2 degrees over all joint angles. Our results showed that the open-source OpenSense framework not only serves as a valid tool for realistic representation of joint kinematics and fRoM, but also yields valid results for IMU sensor selection for a comprehensive set of ADLs involving upper and lower limbs. The results can help researchers to determine appropriate sensor positions and sensor configurations without the need for detailed biomechanical knowledge.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Modification of an IMU Based System for Analyzing Hand Kinematics During Activities of Daily Living
    Muslim, Taif Nabeel
    Lafta, Hassanain Ali
    INTERNATIONAL JOURNAL OF ONLINE AND BIOMEDICAL ENGINEERING, 2023, 19 (15) : 34 - 49
  • [2] Optimization of IMU Sensor Placement for the Measurement of Lower Limb Joint Kinematics
    Niswander, Wesley
    Wang, Wei
    Kontson, Kimberly
    SENSORS, 2020, 20 (21) : 1 - 16
  • [3] Effects of the soft tissue artefact on the hip joint kinematics during unrestricted activities of daily living
    D'Isidoro, Fabio
    Brockmann, Clara
    Ferguson, Stephen J.
    JOURNAL OF BIOMECHANICS, 2020, 104
  • [4] Sagittal plane knee kinematics can be measured during activities of daily living following total knee arthroplasty with two IMU
    Cornish, Bradley M.
    Diamond, Laura E.
    Saxby, David John
    Lloyd, David G.
    Shi, Beichen
    Lyon, Jenna
    Abbruzzese, Kevin
    Gallie, Price
    Maharaj, Jayishni
    PLOS ONE, 2024, 19 (02):
  • [5] Validation of the advanced activities of daily living scale
    Dias, Ewerton Naves
    da Silva, Jose Vitor
    Pais-Ribeiro, Jose Luis
    Martins, Teresa
    GERIATRIC NURSING, 2019, 40 (01) : 7 - 12
  • [6] Sensor Fusion for Recognition of Activities of Daily Living
    Wu, Jiaxuan
    Feng, Yunfei
    Sun, Peng
    SENSORS, 2018, 18 (11)
  • [7] Joint angle measurement of manipulator and error compensation based on an IMU sensor
    Zhang, Tianlin
    Chen, Sheng
    Xu, Guozheng
    Wang, Chao
    Tan, Caiming
    JOURNAL OF ENGINEERING-JOE, 2019, 2019 (23): : 9001 - 9005
  • [8] Hand Kinematics Characterization While Performing Activities of Daily Living Through Kinematics Reduction
    Jarque-Bou, Nestor J.
    Vergara, Margarita
    Sancho-Bru, Joaquin L.
    Gracia-Ibanez, Veronica
    Roda-Sales, Alba
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (07) : 1556 - 1565
  • [9] Three-Dimensional Shoulder Kinematics to Complete Activities of Daily Living
    Rundquist, Peter J.
    Obrecht, Crystal
    Woodruff, Lesley
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2009, 88 (08) : 623 - 629
  • [10] Annotating Sensor Data to Identify Activities of Daily Living
    Donnelly, Mark
    Magherini, Tommaso
    Nugent, Chris
    Cruciani, Federico
    Paggetti, Cristiano
    TOWARD USEFUL SERVICES FOR ELDERLY AND PEOPLE WITH DISABILITIES, 2011, 6719 : 41 - +