Anti-allergic drug screening in single living mast cells by means of a novel surface plasmon resonance imaging system

被引:1
|
作者
Wang, Qian [1 ]
Zhang, Xuerong [2 ]
Li, Qi [1 ]
Liu, Xiaoang [1 ]
Huang, Yusong [1 ]
Shi, Cheng [1 ]
Shinohara, Hiroaki [3 ]
Liu, Zhenming [1 ]
Zhu, Xianwei [1 ,2 ]
机构
[1] Peking Univ, Sch Pharmaceut Sci, State Key Lab Nat & Biomimet Drugs, Beijing 100191, Peoples R China
[2] Shandong Univ Tradit Chinese Med, Inst Pharm, Jinan 250300, Peoples R China
[3] Univ Toyama, Grad Sch Sci & Engn Res, 3190 Gofuku, Toyama 9308555, Japan
基金
中国国家自然科学基金;
关键词
Surface plasmon resonance imaging (SPRi); technology; SPR resonance angle (SPR-dip); Single living mast cell; Small molecule microarray chip; Phenotypic drug screening; PROTEIN-KINASE-C; ACCURATE DOCKING; DISCOVERY; IDENTIFICATION; DEGRANULATION; INHIBITION; PREDICTION; MEDICINES; RBL-2H3; DESIGN;
D O I
10.1016/j.snb.2024.135286
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In recent years, phenotypic drug screening has achieved renewed prominence, because it can develop drugs for some rare diseases with unknown etiology and without effective therapeutic drugs. Combined with biochip microarray technology, surface plasmon resonance imaging (SPRi) technology based on changes in reflected light intensity has been widely used to analyze interactions between biomolecules, especially for in vitro drug screening. However, changes in reflected light intensity are merely derivative of changes in surface plasmon resonance angles, so current SPRi technology suffers from low accuracy, poor sensitivity, and narrow linear range. In this study, we built an improved SPR microscopic imaging system capable of directly detecting SPR resonance angle (SPR-dip) shifts, with a sensitivity of 8.14 x 10(-6) RIU, and a stability less than +/- 2 m degrees. By optimizing the optical path system, the linear correlation coefficient of the system within the scanning range of 3800 m degrees is 0.9975. Based on this imaging system, we established a reliable screening system for single living mast cell allergy drugs. By developing small molecule microarray chips, we achieved high-throughput screening of 2400 sample points at one time. Our SPR microscopic imaging system integrates the comparative advantages of existing angle-scanning SPRi systems and opens the possibility of new applications in phenotypic drug screening.
引用
收藏
页数:11
相关论文
共 43 条
  • [41] One Hour In Vivo-like Phenotypic Screening System for Anti-cancer Drugs Using a High Precision Surface Plasmon Resonance Device
    Junko Johzuka
    Toshihiro Ona
    Masatoshi Nomura
    Analytical Sciences, 2018, 34 : 1189 - 1194
  • [42] One Hour In Vivo-like Phenotypic Screening System for Anti-cancer Drugs Using a High Precision Surface Plasmon Resonance Device
    Johzuka, Junko
    Ona, Toshihiro
    Nomura, Masatoshi
    ANALYTICAL SCIENCES, 2018, 34 (10) : 1189 - 1194
  • [43] An Assay Using Localized Surface Plasmon Resonance and Gold Nanorods Functionalized with Aptamers to Sense the Cytochrome-c Released from Apoptotic Cancer Cells for Anti-Cancer Drug Effect Determination
    Loo, Jacky Fong-Chuen
    Lau, Pui-Man
    Kong, Siu-Kai
    Ho, Ho-Pui
    MICROMACHINES, 2017, 8 (11):