TRUENESS EVALUATION OF LATEST GENERATION OF INTRAORAL SCANNERS ON COMPLETE-ARCH IMPLANT IMPRESSIONS

被引:2
|
作者
Issever, Dilara Seyma Alpkilic [1 ,2 ]
Deger, Sabire isler [1 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[2] Prof Dr Cavit Orhan Tutengil Sk 4, TR-34116 Istanbul, Turkiye
关键词
AMBIENT LIGHT; ACCURACY; PRECISION;
D O I
10.11607/ijp.7824
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the trueness of five intraoral scanners on a fully edentulous model with seven implants. Materials and Methods: The study model was created from gypsum with seven implant analogs that were placed with 2-mm gingival height and a 0-degree angle at tooth sites 47, 45, 43, 31, 33, 35, and 37 (FDI system). The study model was scanned 10 times (n = 10) with five intraoral scanners (CS 3600, Emerald S, Primescan, Trios 3, and Trios 4). The study model was digitized with a high-resolution industrial desktop scanner, and the data were imported into reverse-engineering software to be used as the reference model. The trueness assessment was performed digitally with superimposition using the software. Linear measurements were calculated as the differences between the centers of the scan bodies on the study models vs the reference model. Volumetric deviations were calculated with root mean square values. Data obtained in the study were analyzed statistically using one-way analysis of variance and Tukey tests. A value of P < .05 was accepted as statistically significant. Results: In linear measurements, Trios 4 showed the best trueness results, followed by Trios 3, Emerald S, Primescan, and CS 3600. Trios 4 showed statistically higher trueness results than CS 3600 (P = .029). However, no statistically significant differences were found between groups in volumetric measurements (P < .05). Conclusions: All of the intraoral scanners used in the study showed favorable deviation values for an edentulous model with seven implants. Trios 4 showed the best trueness values. The latest generation of intraoral scanners can be used in full-arch implant impressions.
引用
收藏
页码:e1 / e12
页数:12
相关论文
共 50 条
  • [41] Orthodontic elastomeric chain as an alternative to dental floss for splinting implant impression copings for complete-arch implant impressions
    Joshi, Amruta A.
    Gaikwad, Amit M.
    Nadgere, Jyoti B.
    Ram, Sabita M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 188 - 189
  • [42] Comparison of different artificial landmarks and scanning patterns on the complete-arch implant intraoral digital scans
    Kanjanasavitree, Primprapa
    Thammajaruk, Putsadeeporn
    Guazzato, Massimiliano
    JOURNAL OF DENTISTRY, 2022, 125
  • [43] Effect of simulated intraoral variables on the accuracy of a photogrammetric imaging technique for complete-arch implant prostheses
    Bratos, Manuel
    Bergin, Jumping M.
    Rubenstein, Jeffrey E.
    Sorensen, John A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02): : 232 - 241
  • [44] In vivo trueness and precision of full-arch implant scans using intraoral scanners with three different acquisition protocols
    Nedelcu, Robert
    Olsson, Pontus
    Thulin, Mans
    Nystrom, Ingela
    Thor, Andreas
    JOURNAL OF DENTISTRY, 2023, 128
  • [45] Effect of different intraoral scanners and post-space depths on the trueness of digital impressions
    Emam, Marwa
    Ghanem, Lomaya
    Sadek, Hoda M. Abdel
    DENTAL AND MEDICAL PROBLEMS, 2024, 61 (04) : 577 - 584
  • [46] Trueness and fit of complete-arch implant-supported frameworks in new-generation additively and subtractively manufactured polymers: An in-vitro study
    Yilmaz, Burak
    Donmez, Mustafa Borga
    Guven, Mehmet Esad
    Jamjoom, Faris Z.
    Kahveci, Cigdem
    Schimmel, Martin
    Cakmak, Gulce
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (05) : 986 - 997
  • [47] Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions
    Wu, Hio Kuan
    Chen, Guanhui
    Wang, Jing
    Zhang, Zhengchuan
    Huang, Xiaoqiong
    Lin, Xiaoxuan
    Deng, Feilong
    Li, Yiming
    JOURNAL OF DENTISTRY, 2024, 140
  • [48] In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems
    Orejas-Perez, Jaime
    Gimenez-Gonzalez, Beatriz
    Ortiz-Collado, Ignacio
    Thuissard, Israel J.
    Santamaria-Laorden, Andrea
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (07)
  • [49] Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
    Ryan Jin Young Kim
    Goran I. Benic
    Ji-Man Park
    Scientific Reports, 11
  • [50] Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
    Kim, Ryan Jin Young
    Benic, Goran, I
    Park, Ji-Man
    SCIENTIFIC REPORTS, 2021, 11 (01)