Permanent Magnet-Based Superficial Flow Velometer With Ultralow Output Drift

被引:28
|
作者
Wang, Zhangtao [1 ]
Wang, Shaoping [1 ,2 ,3 ]
Wang, Xingjian [1 ,2 ,3 ]
Luo, Xuesong [4 ]
机构
[1] Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100191, Peoples R China
[2] Beihang Univ, Ningbo Inst Technol, Ningbo 315800, Peoples R China
[3] Tianmushan Lab, Hangzhou 310023, Peoples R China
[4] Tsinghua Univ, Natl Engn Res Ctr Neuromodulat, Sch Aerosp Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Artificial lateral line; electric double layer (EDL); electrode polarization voltage; electromagnetic flowmeter; electromagnetic ocean current meter; electromagnetic velocity meter; ELECTROMAGNETIC FLOWMETER;
D O I
10.1109/TIM.2023.3304692
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Superficial flow velocity perception is inspired by aquatic organisms and has become increasingly important for underwater robots and vehicles. Existing marine electromagnetic velometers require very large alternating current (ac) coils with high power consumption for excitation, limiting their mobility and underwater applications. Permanent magnet excitation is preferable for miniature flow sensors because of low power consumption, small size, and high sensitivity. However, permanent magnet excitation has not been applicable due to the high output drift caused by electrode polarization voltage. This article proposes a permanent magnet-based flow velocity meter that measures the velocity based on the electrode output current instead of the output voltage. The relationship between the output current and the fluid velocity, fluid conductivity, permanent magnet parameters, and electrode position during permanent magnet excitation is derived, and a finite element simulation is conducted. A signal processing circuit is designed to obtain the current output. The experimental results show that the output drift ratio of the proposed sensor is 92% lower than that of the sensor measuring the voltage output, and the measurement R-2 is 0.998 in the test range of 0-0.875 m/s.
引用
收藏
页数:12
相关论文
共 37 条
  • [21] Temperature compensation strategy of output torque for permanent magnet synchronous motor based on BP neural network
    Ma, Zhenglei
    Zhang, Qian
    Wang, Qunjing
    Liu, Tong
    PROCEEDINGS OF THE 2017 12TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2017, : 774 - 779
  • [22] The Flux-Based Sensorless Field-Oriented Control of Permanent Magnet Synchronous Motors without Integrational Drift
    Strinic, Tomislav
    Silber, Siegfried
    Gruber, Wolfgang
    ACTUATORS, 2018, 7 (03)
  • [23] Underwater Surface Flow Velocity Sensor Based on Single Side Stray Field of Permanent Magnet
    Wang, Zhangtao
    Wang, Shaoping
    Luo, Xuesong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [24] Linear kalman filter(LKF) sensorless control for permanent magnet synchronous motor based on orthornal output linear model
    Huang, M. C.
    Moses, A. J.
    Anayi, F.
    Yao, X. G.
    2006 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3, 2006, : 1381 - +
  • [25] A New Optimization of Segmented Interior Permanent Magnet Synchronous Motor Based on Increasing Flux Weakening Range and Output Torque
    Arehpanahi, M.
    Kheiry, E.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2020, 33 (06): : 1122 - 1127
  • [26] Feed-forward Control for Permanent Magnet Synchronous Generator Based Wind Turbine Aimed at Output Power Smoothing
    Zhou, Linyuan
    Liu, Jinjun
    Zhou, Sizhan
    Zhu, Yangque
    Liu, Fangcheng
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 1305 - 1309
  • [27] Nonlinear filtering-based output tracking error constraint control for permanent magnet synchronous motors with complete unknown coefficients
    Wang, Jinying
    Wang, Yanping
    INTERNATIONAL JOURNAL OF ADAPTIVE CONTROL AND SIGNAL PROCESSING, 2023, 37 (01) : 264 - 277
  • [28] Design and development of samarium cobalt based permanent magnet flow meter for 100 NB pipe in sodium circuits
    Rajan, K. K.
    Sharma, Vijay
    Vijayakumar, G.
    Jayakumar, T.
    ANNALS OF NUCLEAR ENERGY, 2015, 76 : 357 - 366
  • [29] Characterization of displacement forces and image artifacts in the presence of passive medical implants in low-field (<100 mT) permanent magnet-based MRI systems, and comparisons with clinical MRI systems
    Van Speybroeck, C. D. E.
    O'Reilly, T.
    Teeuwisse, W.
    Arnold, P. M.
    Webb, A. G.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 : 116 - 124
  • [30] Aviation Fuel Pump Flow Control based Permanent Magnet Synchronous Motor DC-Link current Sampling
    He, Tiantian
    Ma, Ruiqing
    Hu, Chengzhuo
    Chen, Bo
    Zhou, Yang
    Liang, Jingzhi
    2024 THE 7TH INTERNATIONAL CONFERENCE ON ENERGY, ELECTRICAL AND POWER ENGINEERING, CEEPE 2024, 2024, : 384 - 389