Investigation on Co-combustion characteristics and NOX emissions of coal and municipal sludge in a tangentially fired boiler

被引:17
|
作者
Wang, Chang'an [1 ]
Chen, Meijing [1 ]
Zhao, Pengbo [1 ,2 ]
Zhou, Lei [1 ]
Hou, Yujie [1 ]
Zhang, Jinming [1 ]
Lyu, Qiang [1 ]
Che, Defu [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
[2] Xian TPRI Boiler & Environm Protect Engn Co Ltd, Xian 710054, Peoples R China
关键词
Municipal sludge; Coal-fired power plant; Co -processing technique; Resource disposal; Pollutant emissions; SEWAGE-SLUDGE; BITUMINOUS COAL; COMBUSTION; TEMPERATURE; PYROLYSIS; FLAME;
D O I
10.1016/j.fuel.2023.127608
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Using the current coal-fired power plant to treat sludge with large annual production is an efficient sludge treatment method. Nevertheless, the majority of the previous studies concentrated on sludge co-firing with low blending ratio and moisture content in utility boiler. Further analysis and discussion are necessary regarding the impact of sludge with high blending ratio and high moisture content on co-firing performance as well as the potential interactions between high moisture content sludge and coal during the co-firing process. The simulation results of the verified computational fluid dynamic (CFD) model can be regarded as numerical experiments. In the present research, CFD was used to analyze the co-firing characteristics of municipal sludge and coal in a 600 MW tangentially fired utility boiler. The impacts of sludge moisture content, blending ratio, blending strategy, and secondary air (SA) distribution on co-combustion characteristics and NOX emissions were investigated, and their potential synergistic effects were assessed. The co-firing of coal and sludge has little impact on the furnace outlet temperature while potentially lowering NOX emissions, provided that the net calorific value of the feeding of the mixture of sludge and coal is kept constant. The reduction of sludge moisture content can significantly improve co-combustion performance, but it also facilitates NOX production. Blending sludge from the position of the medium-upper burners can reduce the number of layers needed to burn the sludge in practical coal-fired boiler. Furthermore, the SA distribution has a major impact on the furnace outlet flue gas temperature and NOX content. The shrunk-middle type is the optimum scheme for SA distribution. This study contributes to a deeper knowledge of the actual co-firing of sludge and coal in the utility boiler and provides a possible theoretical foundation for the widespread, clean, and effective use of sludge.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Co-combustion of coal with printing and dyeing sludge: Numerical simulation of the process and related NOX emissions
    Hu, Zhifeng
    Ma, Xiaoqian
    Chen, Yumeng
    Liao, Yanfen
    Wu, Jie
    Yu, Zhaosheng
    Li, Shuangshuang
    Yin, Libao
    Xu, Qisheng
    FUEL, 2015, 139 : 606 - 613
  • [22] Combustion process simulation of a tangentially coal blend fired boiler
    Fang, Qingyan
    Zhou, Huaichun
    Huang, Lai
    Yao, Bin
    Wang, Huajian
    PROCEEDINGS OF THE 6TH INTERNATIONAL SYMPOSIUM ON COAL COMBUSTION, 2007, : 280 - 287
  • [23] CO-COMBUSTION OF MUNICIPAL SEWAGE SLUDGE AND HARD COAL ON FLUIDIZED BED BOILER WF-6
    Rajczyk, Rafal
    Bien, Jurand
    Palka, Henryk
    Pogodzinski, Andrzej
    Smorag, Hubert
    ARCHIVES OF ENVIRONMENTAL PROTECTION, 2014, 40 (03) : 101 - 113
  • [24] Environmental investigation on co-combustion of sewage sludge and coal gangue: SO2, NOx and trace elements emissions
    Yang, Zhenzhou
    Zhang, Yingyi
    Liu, Lili
    Wang, Xidong
    Zhang, Zuotai
    WASTE MANAGEMENT, 2016, 50 : 213 - 221
  • [25] Formation Characteristics of Particulate Matters During the Co-combustion of Municipal Sewage Sludge and Coal
    Zhou K.
    Liu H.
    Liu T.
    Zhang J.
    Jing Z.
    Wen C.
    Xu M.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (09): : 3286 - 3294
  • [26] Numerical investigation of low NOx combustion strategies in tangentially-fired coal boilers
    Zhang, Xiaohui
    Zhou, Jue
    Sun, Shaozeng
    Sun, Rui
    Qin, Ming
    FUEL, 2015, 142 : 215 - 221
  • [27] Co-combustion of sludge with coal
    Nadziakiewicz, J
    Koziol, M
    APPLIED ENERGY, 2003, 75 (3-4) : 239 - 248
  • [28] Gaseous Emissions from the Co-combustion of Wet Sludge and Coal
    Li, H.
    Li, Y.
    Jin, Y.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2015, 37 (19) : 2064 - 2072
  • [29] Numerically Study on Combustion and NOx Emission Characteristics in Tangentially Fired Boiler Co-firing Semi-coke
    Du, Yongbo
    Wang, Chang'an
    Wang, Pengqian
    Lv, Qiang
    Che, Defu
    PROCEEDINGS OF THE ASME POWER CONFERENCE, 2018, VOL 1, 2018,
  • [30] Combustion characteristics and NOx release of sludge combustion with coal in a 660 MW boiler
    Ji, Xingliang
    Yang, Qianyu
    Huang, Xinyue
    Wei, Daining
    Wang, Tao
    Sun, Baomin
    APPLIED THERMAL ENGINEERING, 2025, 258