Effect of different fixation methods on biomechanical property of cervical vertebral body replacement and fusion

被引:4
|
作者
Zhang, Dong-Xiang [1 ]
Guo, Li-Xin [1 ]
机构
[1] Northeastern Univ, Sch Mech Engn & Automat, Shenyang 110819, Peoples R China
基金
中国国家自然科学基金;
关键词
Vertebral body replacement and fusion; Anterior fixation; Self-stabilizing fixation; Anterior-posterior fixation; Cervical spine; Finite element; LUMBAR SPINE; MECHANICAL-PROPERTIES; STRUCTURAL-PROPERTIES; EXPANDABLE CAGES; FLEXION; DEGENERATION; CORRIDORS; STRENGTHS; MODEL; LOAD;
D O I
10.1016/j.clinbiomech.2022.105864
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The main purpose of this study was to examine the effect of different fixation methods (anterior fixation, self-stabilizing fixation and anterior-posterior fixation) on biomechanical property of vertebral body replacement and fusion.Methods: Three finite element models of cervical vertebral body replacement and fusion were established. The implanted models included artificial vertebral body and fixation system, and the loads imposed on the models included 75 N compression load and 1 Nm moment load.Findings: For anterior-posterior fixation, the cervical load was mainly transmitted by the posterior pedicle screw and rod (more than 50%), and the stress shielding problem was the most significant than the self-stabilizing and anterior fixation. Self-stabilizing fixation was more helpful to the fusion of implant and vertebrae, but the higher risk of vertebral body collapse was worthy of attention if the cervical spine with osteoporosis. The stress of bone was mainly concentrated around the screw hole. The maximum stress (20.03 MPa) was lower than the yield stress of cortical bone and the possibility of fracture around the fixation device of cervical spine was low. The anterior fixation could meet the requirement of vertebral body replacement and fusion, and the addition of posterior pedicle screws and rods might obtain better treatment in cases of severe spine injury or osteoporosis.Interpretation: The findings of this study may provide guidance on clinical treatments for choosing more appropriate fixation methods for different patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] BIOMECHANICAL CHARACTERIZATION OF VERTEBRAL BODY REPLACEMENT IN SITU: EFFECTS OF DIFFERENT FIXATION STRATEGIES
    Dong, Enchun
    Kang, Jianfeng
    Li, Dichen
    Wang, Ling
    TISSUE ENGINEERING PART A, 2022, 28 : S38 - S38
  • [2] Biomechanical characterization of vertebral body replacement in situ: Effects of different fixation strategies
    Dong, Enchun
    Shi, Lei
    Kang, Jianfeng
    Li, Dichen
    Liu, Bin
    Guo, Zheng
    Wang, Ling
    Li, Xiangdong
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 197
  • [3] Biomechanical comparison of expandable cages for vertebral body replacement in the cervical spine
    Kandziora, F
    Pflugmacher, R
    Schaefer, J
    Scholz, M
    Ludwig, K
    Schleicher, P
    Haas, NP
    JOURNAL OF NEUROSURGERY, 2003, 99 (01) : 91 - 97
  • [4] Sensitivity analysis of biomechanical effect in vertebral body of two different augmenters
    Sun Yuewan
    Wang Dongmei
    Wang Wei
    Sun Jingchuan
    Liu Anmin
    Shi Jiangang
    CLINICAL BIOMECHANICS, 2020, 80 (80)
  • [5] Translocation of Cervical Vertebral Body Replacement Device into the Esophagus
    Pennington, Zach
    Hersh, Andrew M.
    Lo, Sheng-Fu Larry
    WORLD NEUROSURGERY, 2021, 150 : 144 - 146
  • [6] Analysis of the Biomechanical Effects of Vertebral Body Tethering With Apical Fusion
    Frank, Jil
    Trobisch, Per David
    Pishnamaz, Miguel
    Hildebrand, Frank
    Praster, Maximilian
    SPINE, 2025, 50 (06) : E110 - E117
  • [7] Different fixation methods for extracranial vertebral radiosurgery
    Roosenthaler, Shanna
    Roosenthaler, S.
    Mutsaers, L.
    Lazeroms, T.
    Rabe, E.
    Bodis, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1138 - 1139
  • [8] A Biomechanical Study to Evaluate the Effect of PMMA Augmentation and Restoration of the Strength of Cervical Vertebral Screws Inserted in an Osteoporotic Vertebral Body
    Chen, Chun
    Zhao, Weidong
    Liu, Dongxu
    Sun, Peidong
    Wu, Changfu
    Ouyang, Jun
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (04): : 224 - 231
  • [9] Comparative biomechanical compression testing with a new implant for vertebral body replacement
    Knop, C
    Lange, U
    Bastian, L
    Oeser, M
    Blauth, M
    UNFALLCHIRURG, 2001, 104 (01): : 25 - 33
  • [10] Biomechanical compression tests with a new implant for thoracolumbar vertebral body replacement
    Knop, C
    Lange, U
    Bastian, L
    Oeser, M
    Blauth, M
    EUROPEAN SPINE JOURNAL, 2001, 10 (01) : 30 - 37