Magnetic resonance elastography for assessment of testicular stiffness in patients with varicocele Testis MR elastography

被引:0
|
作者
Pocan, Suheyl [1 ]
Karakas, Levent [2 ]
机构
[1] Nisantasi Univ, Fac Med, Dept Radiol, Istanbul, Turkiye
[2] Hlth Sci Univ, Istanbul Gaziosmanpasa Training & Res Hosp, Dept Radiol, Fac Med, Istanbul, Turkiye
关键词
Elastography; Magnetic Resonance; Stiffness; Varicocele; SHEAR-WAVE ELASTOGRAPHY; MEN;
D O I
10.4328/ACAM.21925
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: The purpose of this study was to evaluate the stiffness and volume of the testes in adult patients with varicocele using Doppler ultrasonography (DUS) and magnetic resonance elastography (MR-E), and to compare the findings to those from the patients with normal contralateral testes and those from healthy controls. Material and Methods: A prospective comparison research with 46 varicocele patients (92 testes) and 46 control patients (92 testes) was ethically authorized. There were 92 healthy control testes in Group III, 40 healthy contralateral testes in Group II, and a total of 52 testes with varicocele in Group I. Group comparisons were made using one-way analysis of variance (ANOVA), and binary comparisons were made using Student's t-test. Using Pearson's correlation test, the relationship between testicular stiffness and volume was investigated. Results: The mean MR-E stiffness values did not significantly differ between the two groups or the three groups (P 0.05). The mean testicular volume varied significantly between groups I and III (P = 0.022). The difference between groups I and II (P = 0.716) and groups II and III (P = 0.074) did not, however, differ significantly. In any group, there was no statistically significant relationship between testicular volume and stiffness. Discussion: Testicular volume or varicocele was not significantly correlated with MR-E readings. The accuracy of MR-E in predicting testicular parenchymal injury requires further research with larger patient groups.
引用
收藏
页码:325 / 329
页数:5
相关论文
共 50 条
  • [31] Assessment of Hepatic Fibrosis by Magnetic Resonance Elastography in Patients With Sclerosing Cholangitis
    Nguyen, Doris
    Talwalkar, Jayant A.
    Yin, Meng
    Lindor, Keith D.
    Ehman, Richard L.
    GASTROENTEROLOGY, 2011, 140 (05) : S919 - S919
  • [32] Magnetic resonance elastography in the assessment of hepatic fibrosis: a study comparing transient elastography and histological data in the same patients
    Toguchi, Masafumi
    Tsurusaki, Masakatsu
    Yada, Norihisa
    Sofue, Keitaro
    Hyodo, Tomoko
    Onoda, Minori
    Numoto, Isao
    Matsuki, Mitsuru
    Imaoka, Izumi
    Kudo, Masatoshi
    Murakami, Takamichi
    ABDOMINAL RADIOLOGY, 2017, 42 (06) : 1659 - 1666
  • [33] Magnetic resonance elastography in the assessment of hepatic fibrosis: a study comparing transient elastography and histological data in the same patients
    Masafumi Toguchi
    Masakatsu Tsurusaki
    Norihisa Yada
    Keitaro Sofue
    Tomoko Hyodo
    Minori Onoda
    Isao Numoto
    Mitsuru Matsuki
    Izumi Imaoka
    Masatoshi Kudo
    Takamichi Murakami
    Abdominal Radiology, 2017, 42 : 1659 - 1666
  • [34] COMPARISON OF TRANSIENT ELASTOGRAPHY AND MAGNETIC RESONANCE ELASTOGRAPHY FOR ASSESSMENT OF MASLD/MASH: A RETROSPECTIVE REVIEW
    Mathur, Anandita
    Paredes-Marin, Alejandra
    Ozkaya, Efe
    Rosberger, Sonam
    Sigel, Keith
    Taouli, Bachir
    Bansal, Meena
    HEPATOLOGY, 2024, 80 : S661 - S661
  • [35] Prognostic Value of Spleen Stiffness Assessed by Magnetic Resonance Elastography in Patients with Heart Failure
    Takahashi, Akinori
    Nagai, Toshiyuki
    Tada, Atsushi
    Kato, Yoshiya
    Tsuneta, Satonori
    Mori, Yuki
    Hamaya, Takeshi
    Naito, Seiichiro
    Takenaka, Sakae
    Konishi, Takao
    Sato, Takuma
    Kamiya, Kiwamu
    Anzai, Toshihisa
    CIRCULATION, 2024, 150
  • [36] Liver stiffness measurement in patients with nodular regenerative hyperplasia undergoing magnetic resonance elastography
    Cannella, Roberto
    Minervini, Marta I.
    Rachakonda, Vikrant
    Bollino, Gideon
    Furlan, Alessandro
    ABDOMINAL RADIOLOGY, 2020, 45 (02) : 373 - 383
  • [37] Liver stiffness measurement in patients with nodular regenerative hyperplasia undergoing magnetic resonance elastography
    Roberto Cannella
    Marta I. Minervini
    Vikrant Rachakonda
    Gideon Bollino
    Alessandro Furlan
    Abdominal Radiology, 2020, 45 : 373 - 383
  • [38] Evaluation of Liver Stiffness With Magnetic Resonance Elastography in Patients With Constrictive Pericarditis: Preliminary Findings
    Fenstad, Eric R.
    Dzyubak, Bogdan
    Oh, Jae K.
    Williamson, Eric E.
    Glockner, James F.
    Young, Phillip M.
    Anavekar, Nandan S.
    Leise, Michael D.
    Ehman, Richard L.
    Araoz, Philip A.
    Venkatesh, Sudhakar K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (01) : 81 - 88
  • [39] PROGNOSTIC SIGNIFICANCE OF LIVER STIFFNESS ASSESSED BY MAGNETIC RESONANCE ELASTOGRAPHY IN PATIENTS WITH HEART FAILURE
    Tada, Atsushi
    Nagai, Toshiyuki
    Kato, Yoshiya
    Omote, Kazunori
    Takahashi, Yuki
    Saiin, Kohei
    Naito, Seiichiro
    Takenaka, Sakae
    Mizuguchi, Yoshifumi
    Kobayashi, Yuta
    Konishi, Takao
    Sato, Takuma
    Kamiya, Kiwamu
    Anzai, Toshihisa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 431 - 431
  • [40] Assessment of stiffness changes in the ex vivo porcine aortic wall using magnetic resonance elastography
    Xu, Lei
    Chen, Jun
    Yin, Meng
    Glaser, Kevin J.
    Chen, Qingshan
    Woodrum, David A.
    Ehman, Richard L.
    MAGNETIC RESONANCE IMAGING, 2012, 30 (01) : 122 - 127