Sub-wavelength thick ITO-incorporated PCF based biosensor for non-invasive sensing of glucose and urea

被引:0
|
作者
Islam, Mohammad Atiqul [1 ]
Islam, Sharnali [2 ]
Ali, Khaleda [2 ]
机构
[1] Univ Dhaka, Semicond Technol Res Ctr, Dhaka, Bangladesh
[2] Univ Dhaka, Dept Elect & Elect Engn, Dhaka, Bangladesh
来源
OPTICS CONTINUUM | 2023年 / 2卷 / 11期
关键词
PHOTONIC CRYSTAL FIBER; PLASMON RESONANCE BIOSENSOR;
D O I
10.1364/OPTCON.506356
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This study presents an ultrathin indium tin oxide coated photonic crystal fiber (PCF) incorporated biosensor, suitable for sensing glucose and urea from in-vitro samples. The proposed device detects analytes with refractive indices spanning from 1.32 to 1.36 with maximum amplitude sensitivity of 231 RIU-1. A peak wavelength sensing capability of 12,000 nm/RIU at near-infrared spectrum (1400-2000nm) has also been achieved. Our design incorporates miniature air holes in the PCF to excite core-guided mode and one-tenth of the operating wavelength thick indium tin oxide (ITO) based cladding as the adaptive plasmonic surface. Air gaps in an "X" pattern, etched along the cross-sectional plane of the PCF, enhance the phase coherence between the plasmonic and the core-guided mode for Y polarized light for a narrow spectrum, ensuring higher Q-factor and hence greater sensitivity. The design is characterized using finite element method (FEM) with sensor resolutions as high as 8.33 x 10-6 RIU.
引用
收藏
页码:2436 / 2450
页数:15
相关论文
共 28 条
  • [21] Non-Invasive Blood Glucose Estimation System Based on a Neural Network with Dual-Wavelength Photoplethysmography and Bioelectrical Impedance Measuring
    Yen, Chih-Ta
    Chen, Un-Hung
    Wang, Guo-Chang
    Chen, Zong-Xian
    SENSORS, 2022, 22 (12)
  • [22] Highly sensitive non-invasive glucose sensing based on chitosan-coated MXene/NiCo-LDH composites
    Yin, Jingwen
    Zhang, Hongteng
    Wang, Yue
    Hasebe, Yasushi
    Dong, Yan
    Zhang, Zhiqiang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2025, 984
  • [23] Non-Invasive Real-Time Monitoring of Glucose Level Using Novel Microwave Biosensor Based on Triple-Pole CSRR
    Omer, Ala Eldin
    Shaker, George
    Safavi-Naeini, Safieddin
    Alquie, Georges
    Deshours, Frederique
    Kokabi, Hamid
    Shubair, Raed M.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2020, 14 (06) : 1407 - 1420
  • [24] Reusable, Non-Invasive, and Ultrafast Radio Frequency Biosensor Based on Optimized Integrated Passive Device Fabrication Process for Quantitative Detection of Glucose Levels
    Li, Yang
    Yao, Zhao
    Yue, Wenjing
    Zhang, Chunwei
    Gao, Song
    Wang, Cong
    SENSORS, 2020, 20 (06)
  • [25] Swept-wavelength lasers based on GaSb gain-chip technology for non-invasive biomedical sensing applications in the 1.7-2.5 μm wavelength range
    Vizbaras, Augustinas
    Simonyte, Ieva
    Miasojedovas, Arunas
    Trinkunas, Augustinas
    Buciunas, Tadas
    Greibus, Mindaugas
    Naujokaite, Greta
    Torcheboeuf, Nicolas
    Droz, Serge
    Boiko, Dmitri
    Dambrauskas, Zilvinas
    Gulbinas, Antanas
    Vizbaras, Kristijonas
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (10): : 4834 - 4849
  • [26] Sensitivity evaluation of miniature microstrip line-based sensors using multiple sensing parameters for non-invasive blood glucose monitoring
    Afshari N.
    Hashemi S.M.
    Geran F.
    IET Microwaves, Antennas and Propagation, 2023, 17 (11): : 872 - 886
  • [27] Non-Invasive Disposable 2D Ti3C2Tx based Enzyme Free Electrochemical Sweat Glucose Biosensor
    Saraswathi, K. A.
    Reddy, M. Sai Bhargava
    Jayarambabu, N.
    Rao, K. Venkateswara
    Aich, Shampa
    Rao, T. Venkatappa
    MICROCHEMICAL JOURNAL, 2024, 205
  • [28] Non-invasive determination of glucose directly in raw fruits using a continuous flow system based on microdialysis sampling and amperometric detection at an integrated enzymatic biosensor
    Vargas, E.
    Ruiz, M. A.
    Campuzano, S.
    Reviejo, A. J.
    Pingarron, J. M.
    ANALYTICA CHIMICA ACTA, 2016, 914 : 53 - 61