Numerical model of an industrial refrigeration system for condensation temperature optimisation

被引:1
|
作者
Giovannini, Michael [1 ]
Lorenzini, Marco [1 ]
机构
[1] Univ Bologna, Dept Ind Engn, Via Fontanelle 40, I-47121 Forli, Italy
关键词
Food refrigeration; Energy consumption minimisation; Evaporative condensers; EVAPORATIVE CONDENSER;
D O I
10.1016/j.tsep.2023.101846
中图分类号
O414.1 [热力学];
学科分类号
摘要
Refrigeration plants in the food industry have a key role, yet are very energy-intensive, which poses a serious problem given the current steep rise of energy prices. In this framework, energy consumption minimisation represents a paramount goal for plant managers, yet most are loathe to test new control strategies in real-life plants, lest normal operation be disrupted and food be spoiled as a consequence. In this view, numerical models able to demonstrate the reduction in energy consumption which can be achieved with suitable conduction strategies, especially in the case when evaporative condensers are employed, appear the ideal tool to provide the manager with an estimation of the potential savings and spur them into adopting such strategies. In this work one such model is developed for the primary loop of the refrigeration plant of a warehouse for food storage located in northern Italy. The choice of the model type is discussed at length, as are modelling issues related to all main components of the loop. The model has been validated with operational data from the real-life plant and employed to determine the optimal condensation pressure corresponding to the minimum total energy consumption according to ambient conditions. The method and model can be applied to other, similar plants in order to minimise their energy consumption.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Numerical Analysis of Steam Ejector Performance with Non-Equilibrium Condensation for Refrigeration Applications
    Lei, Yu
    Li, Shengyu
    Lu, Jun
    Xu, Ye
    Yong, Yong
    Xing, Dingding
    BUILDINGS, 2023, 13 (07)
  • [32] Experimental Study on Intermittent Operation Characteristics of Zeotropic Mixture Partial Condensation Based Dual-temperature Refrigeration System
    Chen, Qi
    Yan, Gang
    Wu, Qingping
    Yu, Jianlin
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (07): : 1815 - 1823
  • [33] OPTIMUM TEMPERATURE STAGING OF CRYOGENIC REFRIGERATION SYSTEM
    JEONG, S
    SMITH, JL
    CRYOGENICS, 1994, 34 (11) : 929 - 933
  • [34] Numerical Modeling and Thermal Analysis of an Adsorption Refrigeration System
    Sur, Anirban
    Das, Randip K.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2015, 23 (04)
  • [35] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi 'an
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
  • [36] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi'An
    Case Studies in Thermal Engineering, 2022, 39
  • [37] Numerical optimisation for model evaluation in combustion kinetics
    Fischer, M.
    Jiang, X.
    APPLIED ENERGY, 2015, 156 : 793 - 803
  • [38] Development of a Predictive Control Based on Takagi-Sugeno Model Applied in a Nonlinear System of Industrial Refrigeration
    Franco, I. C.
    Schmitz, J. E.
    Costa, T. V.
    Fileti, A. M. F.
    Silva, F. V.
    CHEMICAL ENGINEERING COMMUNICATIONS, 2017, 204 (01) : 39 - 54
  • [39] Fault detection and diagnostic system for an industrial refrigeration installation.
    de Miguel, LJ
    Moya, E
    Candau, J
    Perán, JR
    (SAFEPROCESS'97): FAULT DETECTION, SUPERVISION AND SAFETY FOR TECHNICAL PROCESSES 1997, VOLS 1-3, 1998, : 397 - 403
  • [40] INDUSTRIAL APPLICATION OF A DIRECT REFRIGERATION SYSTEM FOR ENERGY-CONSERVATION
    SHEA, DP
    SHELTON, JE
    WHITE, TL
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1982, 104 (02): : 170 - 173