Evaluation of radon concentration measurements in water using the radon degassing method

被引:4
|
作者
Matsumoto, Maho [1 ]
Yasuoka, Yumi [1 ]
Takakaze, Yui [1 ]
Hosoda, Masahiro [2 ]
Tokonami, Shinji [3 ]
Iwaoka, Kazuki [4 ]
Mukai, Takahiro [5 ]
机构
[1] Kobe Pharmaceut Univ, Radioisotope Res Ctr, Higashinada Ku, 4-19-1 Motoyamakitamachi, Kobe, Hyogo 6588558, Japan
[2] Hirosaki Univ, Dept Radiat Sci, Grad Sch Hlth Sci, 66-1 Hon Cho, Hirosaki, Aomori 0368564, Japan
[3] Hirosaki Univ, Inst Radiat Emergency Med, Dept Radiat Measurement & Phys Dosimetry, 66-1 Hon Cho, Hirosaki, Aomri 0368564, Japan
[4] Natl Inst Quantum Sci & Technol, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[5] Kobe Pharmaceut Univ, Dept Biophys Chem, Higashinada Ku, 4-19-1 Motoyamakitamachi, Kobe, Hyogo 6588558, Japan
关键词
Degassing; Radon; Exposure control; In-situ field measurement;
D O I
10.1007/s10967-022-08698-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study was the first to determine the effectiveness of radon concentration measurement in water using the degassing method as a screening method based on the liquid scintillation counter method. The degassing method used two radon monitors (AlphaGUARD and RAD7) and two monitor-attached degassing devices (AquaKIT and RAD H2O). These were effective screening methods based on the WHO guideline value of 100 Bq L-1. The screening values confirmed that a combination of the AlphaGUARD and AquaKIT was preferred. The results are useful for radon measurement for exposure control in drinking water and environmental in-situ field measurement.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 50 条
  • [41] A study on the radon concentration in water in Coonoor, India
    S. Selvasekarapandian
    R. Sivakumar
    N. M. Manikandan
    V.M. Ragjunath
    V. Kannan
    S. Rajaram
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 252 : 345 - 347
  • [42] RADON CONCENTRATION IN WATER MEASURED BY TRACK DETECTORS
    KVASNICKA, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03): : 563 - 567
  • [43] Estimating the radon concentration in water and indoor air
    A. F. Maged
    Environmental Monitoring and Assessment, 2009, 152 : 195 - 201
  • [44] STATISTICAL VERIFICATION OF THE METHOD OF EVALUATION THE SHORT TERM RADON INTEGRATED MEASUREMENTS
    Dubcakova, Renata
    Praks, Pavel
    Danihelka, Pavel
    16TH INTERNATIONAL CONFERENCE ON SOFT COMPUTING MENDEL 2010, 2010, : 524 - 530
  • [45] RADON SURVEY IN SCHOOL AND ESTIMATION OF EFFECTIVE DOSE USING CORRECTED RADON CONCENTRATION
    Lee, E. R.
    Chang, B. U.
    Kim, Y. J.
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (02) : 101 - 107
  • [46] A COMPARISON OF SEASONAL RADON CONCENTRATION AND WEEKLY SCREENING MEASUREMENTS
    AZIMIGARAKANI, D
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 263 - 265
  • [47] RESULTS OF RADON CONCENTRATION MEASUREMENTS IN SOME REGIONS OF RUSSIA
    MARENNY, AM
    VOROZHTSOV, AS
    NEFEDOV, NA
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 649 - 653
  • [48] Radon concentration measurements in the AMASRA coal mine, Turkey
    Baldik, R
    Aytekin, H
    Çelebi, N
    Ataksor, B
    Tasdelen, M
    RADIATION PROTECTION DOSIMETRY, 2006, 118 (01) : 122 - 125
  • [49] RADON AND RADON DAUGHTER MEASUREMENTS IN SOLAR BUILDINGS
    GEORGE, AC
    KNUTSON, EO
    FRANKLIN, H
    HEALTH PHYSICS, 1983, 45 (02): : 413 - 420
  • [50] MEASUREMENTS OF RADON AND RADON DAUGHTERS IN DWELLINGS IN ALGIERS
    CHEROUATI, DE
    DJEFFAL, S
    RADIATION PROTECTION DOSIMETRY, 1988, 25 (02) : 137 - 139