Feasibility of rapid gravity filtration and membrane ultrafiltration for the removal of microplastics and microlitter in sewage and wastewater from plastic industry

被引:35
|
作者
Gonzalez-Camejo, J. [1 ]
Morales, A. [2 ]
Pena-Lamas, J. [2 ]
Lafita, C. [3 ]
Enguidanos, S. [3 ]
Seco, A. [4 ]
Marti, N. [4 ]
机构
[1] Univ Politecn Valencia, Inst Univ Invest Engn Aigua & Medi Ambient IIAMA, CALAGUA Unidad Mixta UV UPV, Cami Vera S-N, Valencia 46022, Spain
[2] Valencia Parc Tecnol, Inst Tecnol Plast, AIMPLAS AIMPLAS, Carrer Gustave Eiffel 4, Valencia 46980, Spain
[3] Global Omnium, Camino Picana 16, Valencia 46014, Spain
[4] Univ Valencia, Dept Engn Quim, CALAGUA Unidad Mixta UV UPV, Avinguda Univ S-N, Valencia 46100, Spain
关键词
Microlitter; Microplastics; Rapid filtration; Ultrafiltration; Wastewater; HOLLOW-FIBER MEMBRANES; TREATMENT PLANTS; FATE; IDENTIFICATION; QUANTIFICATION; TECHNOLOGIES; ENVIRONMENT; SYSTEM;
D O I
10.1016/j.jwpe.2022.103452
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wastewater treatment plants (WWTPs) act as barriers in reducing uncontrolled microplastic and microlitter (MPML) emissions from both urban and industrial wastewaters. Despite removing most of the MP-ML, large quantities of this waste still enter the environment through WWTP effluents, which means further post-treatment technologies are needed. This study contains a technical evaluation of MP-ML removal from urban wastewater (UWW) and from the wastewater from the recycling plastic industry (PIWW) using two different pilot-scale post-treatment systems: rapid gravity filtration (RGF) and ultrafiltration (UF) membranes. The MP-ML mass concentrations contained in UWW and PIWW were measured by a simplified method adapted for the long-term monitoring of WWTP operations. The method was validated on standard samples. Despite the RGF system consumed less energy than UF treating UWW (0.097 kWh???m??? 3 and 0.156 kWh???m??? 3, respectively), RGF was not efficient enough to properly decrease the risk of MP-ML emissions (39.5 ?? 34.6 % of MP-ML removal). With respect to PIWW, the energy consumption of the UF plant decreased up to 0.059 kWh???m??? 3. The combination of RGF and UF technologies was expected to reduce membrane fouling but it did not show significant differences in the mid-term operation.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Recent advances in membrane filtration for heavy metal removal from wastewater: A mini review
    Xiang, Hongrui
    Min, Xiaobo
    Tang, Chong-Jian
    Sillanpaa, Mika
    Zhao, Feiping
    JOURNAL OF WATER PROCESS ENGINEERING, 2022, 49
  • [22] Hybrid flotation -: membrane filtration process for the removal of heavy metal ions from wastewater
    Blöcher, C
    Dorda, J
    Mavrov, V
    Chmiel, H
    Lazaridis, NK
    Matis, KA
    WATER RESEARCH, 2003, 37 (16) : 4018 - 4026
  • [23] Microplastics and pharmaceuticals from water and wastewater: Occurrence, impacts, and membrane bioreactor-based removal
    Nguyen, D.
    Nguyen, Minh-Ky
    Truong, Quoc-Minh
    Thai, Van-Anh
    Pham, Minh-Thuan
    Chang, S. Woong
    Nguyen, D. Duc
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 361
  • [24] Electrochemical removal and recovery of phosphorus from wastewater using cathodic membrane filtration reactor
    Lehui Ren
    Jun Xu
    Ruobin Dai
    Zhiwei Wang
    Chinese Chemical Letters, 2023, 34 (04) : 442 - 446
  • [25] A review of the function of using carbon nanomaterials in membrane filtration for contaminant removal from wastewater
    Chadha, Utkarsh
    Selvaraj, Senthil Kumaran
    Vishak Thanu, S.
    Cholapadath, Vishnu
    Abraham, Ashesh Mathew
    Zaiyan, M. Mohammed
    Manoharan, Manikandan
    Paramsivam, Velmurugan
    MATERIALS RESEARCH EXPRESS, 2022, 9 (01)
  • [26] Removal of micropollutants from treated domestic wastewater by addition of powdered activated carbon to rapid filtration
    Altmann, J.
    Bruebach, H.
    Sperlich, A.
    Jekel, M.
    WATER PRACTICE AND TECHNOLOGY, 2014, 9 (03): : 344 - 352
  • [27] Removal of microbes from municipal wastewater effluent by rapid sand filtration and subsequent UV irradiation
    Rajala, RL
    Pulkkanen, M
    Pessi, M
    Heinonen-Tanski, H
    WATER SCIENCE AND TECHNOLOGY, 2003, 47 (03) : 157 - 162
  • [28] Integrated electrocoagulation and membrane filtration for PAH removal from realistic industrial wastewater: effectiveness and mechanisms
    Gong, Chenhao
    Huang, Haiou
    Qian, Yu
    Zhang, Zhongguo
    Wu, Hongbin
    RSC ADVANCES, 2017, 7 (83): : 52366 - 52374
  • [29] Removal of zinc and nickel ions by complexation-membrane filtration process from industrial wastewater
    Gabor Borbely
    Endre Nagy
    DESALINATION, 2009, 240 (1-3) : 218 - 226
  • [30] Application of Sayong Ball Clay Membrane Filtration for Ni (II) Removal from Industrial Wastewater
    Noor, S. F. Mohd
    Ahmad, N.
    Khattak, M. A.
    Khan, M. S.
    Mukhtar, Anique
    Kazi, S.
    Badshah, Saeed
    Khan, Rafiullah
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2017, 11 (06): : 949 - 954