Load Test Method Using Two Small-Capacity Power Supplies for High-Frequency Transformers in Single-Phase Dual Active Bridge Converters

被引:0
|
作者
Orikawa, Koji [1 ]
Ogasawara, Satoshi [1 ]
机构
[1] Hokkaido Univ, Grad Sch Informat Sci & Technol, Sapporo, Hokkaido, Japan
关键词
high-frequency transformer; load test; power loss measurement; single-phase dual active bridge converter; DC-DC CONVERTER; STRATEGY; PERFORMANCE; MODULATION;
D O I
10.1109/APEC43580.2023.10131148
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a load test method using two small-capacity power supplies for high-frequency transformers in single-phase dual active bridge (DAB) converters operated at 40 kHz. It is experimentally verified that the total apparent power for two power supplies is only 56 VA while the rated output power of a test transformer is 1 kW. Moreover, experimental results show the accuracy of power loss measurement is improved compared to a conventional method which obtains the power loss by subtracting an output power from an input power of the transformer because in the proposed load test method the excitation loss and the load loss can be measured directly, and the range of voltage and current of the power analyzer for each power supply can be properly adjusted to the voltage and current of each power supply. This is another advantage of the proposed load test method in addition to reducing the capacity of the power supply for the load test of transformers.
引用
收藏
页码:3288 / 3293
页数:6
相关论文
共 24 条
  • [21] Control Method for Avoiding Transformer Saturation in High-Power Three-Phase Dual-Active Bridge DC-DC Converters
    Voss, Johannes
    Engel, Stefan P.
    De Doncker, Rik W.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (04) : 4332 - 4341
  • [22] A Comparative Review of High-Frequency Transient DC Bias Current Mitigation Strategies in Dual-Active-Bridge DC-DC Converters Under Phase-Shift Modulations
    Bu, Qinglei
    Wen, Huiqing
    Shi, Haochen
    Zhu, Yinxiao
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (02) : 2166 - 2182
  • [23] Power Flow Analysis for 3-Port 3-Phase Dual Active Bridge DC/DC Converter and Design Validation Using High Frequency Planar Transformer
    Baek, Seunghun
    Roy, Sudhin
    Bhattacharya, Subhashish
    Kim, Sungmin
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 388 - 395
  • [24] Detection of normal transitions in a hybrid single-phase Bi2223 high temperature superconducting transformer by using the active power method and a magnetic flux detection coil
    Nanato, N.
    Nakamura, S.
    Tanaka, S.
    29TH INTERNATIONAL SYMPOSIUM ON SUPERCONDUCTIVITY, 2017, 871