Cystic ovarian disease in dairy cattle: Diagnostic accuracy when using B-mode and color Doppler ultrasound

被引:4
|
作者
Turner, Z. B. [1 ]
Lima, F. S. [2 ]
Conley, A. J. [2 ]
McNabb, B. R. [1 ,2 ]
Rowe, J. D. [1 ,2 ]
Garzon, A. [2 ]
Urbano, T. M. [1 ]
Morris, C. M. [1 ]
Pereira, R. V. [1 ,2 ]
机构
[1] Univ Calif Davis, Vet Med Teaching Hosp, Livestock Herd Hlth & Reprod Serv, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Populat Hlth & Reprod, Davis, CA 95616 USA
关键词
cyst; luteal; follicular; endocrine; progesterone; FOLLICULAR CYSTS; RISK-FACTORS; BLOOD-FLOW; COWS; PROGESTERONE; ULTRASONOGRAPHY; SYNCHRONIZATION; INSEMINATION; STRATEGIES; PALPATION;
D O I
10.3168/jds.2022-22498
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The most frequently reported definition of cystic ovarian disease in cattle is an abnormally persistent follicle (>7 to 10 d) with a diameter >25 mm. Dis-crimination between luteal and follicular ovarian cystic structures has traditionally been conducted by mea-suring the rim width of luteal tissue. The most com-mon practice used in the field for diagnosis of cystic ovarian disease is examination by rectal palpation with or without the use of a B-mode ultrasound. Color Dop-pler ultrasound technology allows assessment of blood flow area measurements in the ovary, which has been proposed as a potential indirect measure for plasma progesterone (P4) concentrations. The objective of this study was to compare the diagnostic accuracy of differentiating luteal structures from follicular ovarian cysts using measures collected with B-mode and color Doppler transrectal ultrasonography. The definition of an ovarian cyst was a follicle greater than 20 mm in diameter in the absence of a corpus luteum that per -sisted for at least 10 d. A 3-mm luteal rim width was used to differentiate follicular and luteal cysts. A total of 36 cows were enrolled in the study during routine herd reproductive examination visits, with 26 and 10 having follicular and luteal cysts, respectively. Cows en -rolled in the study were examined using a Mini-ExaPad mini ultrasound with color Doppler capabilities (IMV Imaging Ltd.). Blood samples were collected from each cow to measure P4 serum concentrations. History and signalment of each cow, including days in milk, lacta-tion, times bred, days since last heat, milk composi-tion, and somatic cell counts, were retrieved from an online database (DairyComp 305, Valley Agricultural Software). The accuracy of diagnosing follicular from luteal cysts based on luteal rim thickness was analyzed by receiver operating characteristic (ROC) curve using P4 as the gold standard, where P4 concentrations exceeding 1 ng/mL was defined as luteal, and all other structures with less P4 were considered follicular. Lu-teal rim and blood flow area were selected for further analysis because they presented the best ROC curves for differentiating cystic ovarian structures, with areas under the curve of 0.80 and 0.76, respectively. Luteal rim width of 3 mm was used as the cutoff standard in the study, resulting in sensitivity and specificity of 50% and 86%, respectively. Blood flow area of 0.19 cm2 was used as the cutoff standard in the study, resulting in sensitivity and specificity of 79% and 86%, respectively. When combining the use of luteal rim width and blood flow area to differentiate cystic ovarian structures, a parallel approach resulted in sensitivity and specific-ity of 73% and 93%, respectively, whereas an in-series approach resulted in sensitivity and specificity of 35% and 100%, respectively. In conclusion, the use of color Doppler ultrasonography when discriminating between luteal and follicular ovarian cysts in dairy cattle re-sulted in higher diagnostic accuracy compared with using B-mode ultrasonography alone.
引用
收藏
页码:3411 / 3420
页数:10
相关论文
共 50 条
  • [21] Computer-aided Diagnosis of Breast Tumor Based on B-mode Ultrasound and Color Doppler Flow Imaging
    Diao, Xian-Fen
    Wang, Tian-Fu
    Yang, Ying
    Chen, Si-Ping
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 162 - 166
  • [22] Machine Learning Diagnostic Modeling for Classifying Fibromyalgia Using B-mode Ultrasound Images
    Behr, Michael
    Saiel, Saba
    Evans, Valerie
    Kumbhare, Dinesh
    ULTRASONIC IMAGING, 2020, 42 (03) : 135 - 147
  • [23] AREA MEASUREMENT OF CAROTID PLAQUE COMPARING B-MODE, DOPPLER COLOR AND CONTRAST-ENHANCED ULTRASOUND IMAGING
    Nyman, E.
    Vanoli, D.
    Gronlund, C.
    Naslund, U.
    Lindqvist, P.
    ATHEROSCLEROSIS, 2016, 252 : E191 - E191
  • [24] First results of an ultrasonographic evaluation and characterization of mammary neoplasia in bitches using b-mode and color Doppler mode
    Feliciano, M. A. R.
    Vicente, W. R. R.
    Galera, P. D.
    Castro, M. B.
    REPRODUCTION IN DOMESTIC ANIMALS, 2010, 45 : 86 - 86
  • [25] B-mode and color Doppler ultrasound of the forearm arteries in the preoperative screening prior to coronary artery bypass grafting
    Huzjan, R
    Brkljacic, B
    Delic-Brkljacic, D
    Biocina, B
    Sutlic, Z
    COLLEGIUM ANTROPOLOGICUM, 2004, 28 : 235 - 241
  • [26] Diagnostic Value of Elastography, Strain Ratio, and Elasticity to B-Mode Ratio and Color Doppler Ultrasonography in Breast Lesions
    Ranjkesh, Mahnaz
    Hajibonabi, Farid
    Seifar, Fatemeh
    Tarzamni, Mohammad Kazem
    Moradi, Behzad
    Khamnian, Zhila
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2020, 13 : 215 - 224
  • [28] Diagnostic Accuracy of Echo Envelope Statistical Modeling Compared to B-Mode and Power Doppler Ultrasound Imaging in Patients With Clinically Diagnosed Lateral Epicondylosis of the Elbow
    Bureau, Nathalie J.
    Destrempes, Francois
    Acid, Souad
    Lungu, Eugen
    Moser, Thomas
    Michaud, Johan
    Cloutier, Guy
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (10) : 2631 - 2641
  • [29] Classification of normal and medical renal disease using B-mode ultrasound images
    Subramanya, M. B.
    Kumar, Vinod
    Mukherjee, Shaktidev
    Saini, Manju
    2015 2ND INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT (INDIACOM), 2015, : 1914 - 1918
  • [30] Diagnostic accuracy of B-mode, Doppler ultrasound, strain elastography, and 2D shear wave elastography in differentiation between benign and malignant lymphadenopathy
    Abd-Elmageed, Mohamed Kamel
    Ibrahim, Sahar Gamal
    El Zawawi, Mohammed Salah Eldeen
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01):