Evaluation of a new portable corneal topography system for self-measurement using smartphones: a pilot study

被引:0
|
作者
Kobashi, Hidenaga [1 ,2 ,3 ]
Tsubota, Kazuo [1 ,2 ]
Aoki, Shunsuke [4 ]
Kobayashi, Masaaki [5 ]
Sumali, Brian [6 ]
Mitsukura, Yasue [6 ]
机构
[1] Tsubota Lab Inc, Tokyo, Japan
[2] Keio Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
[3] Ebina Ekimae Eye Clin, Ebina, Kanagawa, Japan
[4] Dentsu ScienceJam Inc, Tokyo, Japan
[5] Stratasys Japan Co Ltd, Tokyo, Japan
[6] Keio Univ, Fac Sci & Technol, Dept Syst Design Engn, Tokyo, Kanagawa, Japan
关键词
Smartphone; Selfie; Keratoconus; Corneal topography; AS-OCT; FOURIER-ANALYSIS;
D O I
10.1007/s00417-024-06426-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeHerein, we propose the use of the "KeraVio Ring", which is a portable, selfie-based, smartphone-attached corneal topography system that is based on the Placido ring videokeratoscope. The goal of this study was to evaluate and compare corneal parameters between KeraVio Ring and conventional corneal tomography images.MethodsWe designed the KeraVio Ring as a device comprising 3D-printed LED rings for generating Placido rings that can be attached to a smartphone. Two LED rings are attached to a cone-shaped device, and both corneas are illuminated. Selfies were taken using the KeraVio Ring attached to the smartphone without assistance from any of the examiners. Captured Placido rings on the cornea were analysed by intelligent software to calculate corneal parameters. Patients with normal, keratoconus, or LASIK-treated eyes were included. Anterior segment optical coherence tomography (AS-OCT) was also performed for each subject.ResultsWe found highly significant correlations between the steepest and flattest keratometry, corneal astigmatism, and vector components obtained with the KeraVio Ring and AS-OCT. In subjects with normal, keratoconus, and LASIK-treated eyes, the mean difference in corneal astigmatism between the two devices was -0.8 +/- 1.4 diopters (D) (95% limits of agreement (LoA), -3.6 to 2.0), -1.8 +/- 3.7 D (95% LoA, -9.1 to 5.5), and -1.5 +/- 1.3 D (95% LoA, -4.0 to 1.1), respectively.ConclusionsThe experimental results showed that the corneal parameters obtained by the KeraVio Ring were correlated with those obtained with AS-OCT. The KeraVio Ring has the potential to address an unmet need by providing a tool for portable selfie-based corneal topography.
引用
收藏
页码:2199 / 2207
页数:9
相关论文
共 50 条
  • [41] Pressure reducing capacity of felt: A feasibility study using a new portable system with thin sensors
    Deschamps, Kevin
    Messier, Benjamin
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 107 (03) : E11 - E14
  • [42] 3-D measurement of posture and back shape using a low cost, portable system - a reliability study
    Warren, JG
    Bettany-Saltikov, J
    Van Schaik, P
    Papastefanou, SL
    RESEARCH INTO SPINAL DEFORMITIES 3, 2002, 88 : 100 - 104
  • [43] Prospective evaluation of oral premalignant lesions using a multimodal imaging system: a pilot study
    Yang, Eric C.
    Vohra, Imran S.
    Badaour, Hawraa
    Schwarz, Richard A.
    Cherry, Katelin D.
    Jacob, Justin
    Rodriguez, Jessica
    Williams, Michelle D.
    Vigneswaran, Nadarajah
    Gillenwater, Ann M.
    Richards-Kortum, Rebecca R.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2020, 42 (02): : 171 - 179
  • [44] A Study on the Shape Evaluation using Non-contact Electromagnetic Measurement System
    Kim, Jae Min
    Yun, Seung Ho
    Won, Hyuk
    Park, Gwan Soo
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2010, 20 (02): : 45 - 51
  • [45] Evaluation of an Acne Severity Grading Self-Assessment System Suitable for the Thai Population - A Pilot Study
    Pakornphadungsit, Kallapan
    Harnchoowong, Sarawin
    Wattanakrai, Penpun
    CLINICAL COSMETIC AND INVESTIGATIONAL DERMATOLOGY, 2023, 16 : 3171 - 3179
  • [46] Evaluation of lumbar segmental instability in degenerative diseases by using a new intraoperative measurement system
    Hasegawa, Kazuhiro
    Kitahara, Ko
    Hara, Toshiaki
    Takano, K.
    Shimoda, Haruka
    Homma, Takao
    JOURNAL OF NEUROSURGERY-SPINE, 2008, 8 (03) : 255 - 262
  • [47] Evaluation of countermeasures for 1.10 MPa frost expansion pressure using a new measurement system
    Okubo, K
    Okamoto, T
    Ryokai, K
    Izuta, H
    GROUND FREEZING 2000: FROST ACTION IN SOILS, 2000, : 299 - 304
  • [48] Outcomes of topography-guided PRK/CXL in keratoconus using the NIDEK CXIII system-"Bharat Protocol" (Pilot study)
    Jain, Rajat
    Shuaib, Yusra
    Mohan, Neha
    Mittal, Vikas
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (09) : 3203 - 3209
  • [49] EVALUATION OF A NEW SYSTEM FOR KINETIC MEASUREMENT OF SERUM GLUTAMIC OXALACETIC TRANSAMINASE - AN INTERLABORATORY STUDY
    WINSTEN, S
    WILKINSON, JH
    BOUTWELL, JH
    CLINICAL CHEMISTRY, 1969, 15 (06) : 496 - +
  • [50] The self-concept of adolescents with cleft lip and palate: a pilot study using a multidimensional/hierarchical measurement instrument
    Gussy, M.
    Kilpatrick, N.
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2006, 16 (05) : 335 - 341