A Silicon-Based PDMS-PEG Copolymer Microfluidic Chip for Real-Time Polymerase Chain Reaction Diagnosis

被引:7
|
作者
Yang, Siyu [1 ,2 ,3 ]
Xian, Qingyue [1 ,2 ]
Liu, Yiteng [1 ,2 ]
Zhang, Ziyi [1 ,2 ]
Song, Qi [4 ]
Gao, Yibo [4 ]
Wen, Weijia [2 ,3 ,4 ]
机构
[1] Hong Kong Univ Sci & Technol, Interdisciplinary Program Off, Div Emerging Interdisciplinary Areas, Clear Water Bay, Hong Kong, Peoples R China
[2] Hong Kong Univ Sci & Technol Guangzhou, Thrust Adv Mat, Guangzhou 511400, Peoples R China
[3] HKUST Shenzhen Hong Kong Collaborat Innovat Res In, Shenzhen 518000, Peoples R China
[4] Hong Kong Univ Sci & Technol, Dept Phys, Clear Water Bay, Hong Kong, Peoples R China
关键词
Real-time PCR; PPc-Si chips; PDMS-PEG copolymer; microfluidic chip; molecular diagnosis; ENZYMATIC AMPLIFICATION; PRENATAL-DIAGNOSIS; ANALYSIS SYSTEMS; BETA-GLOBIN; QF-PCR; DNA; PROTEIN; POINT; ANEUPLOIDIES; SEQUENCES;
D O I
10.3390/jfb14040208
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polydimethylsiloxane (PDMS) has been widely used to make lab-on-a-chip devices, such as reactors and sensors, for biological research. Real-time nucleic acid testing is one of the main applications of PDMS microfluidic chips due to their high biocompatibility and transparency. However, the inherent hydrophobicity and excessive gas permeability of PDMS hinder its applications in many fields. This study developed a silicon-based polydimethylsiloxane-polyethylene-glycol (PDMS-PEG) copolymer microfluidic chip, the PDMS-PEG copolymer silicon chip (PPc-Si chip), for biomolecular diagnosis. By adjusting the modifier formula for PDMS, the hydrophilic switch occurred within 15 s after contact with water, resulting in only a 0.8% reduction in transmittance after modification. In addition, we evaluated the transmittance at a wide range of wavelengths from 200 nm to 1000 nm to provide a reference for its optical property study and application in optical-related devices. The improved hydrophilicity was achieved by introducing a large number of hydroxyl groups, which also resulted in excellent bonding strength of PPc-Si chips. The bonding condition was easy to achieve and time-saving. Real-time PCR tests were successfully conducted with higher efficiency and lower non-specific absorption. This chip has a high potential for a wide range of applications in point-of-care tests (POCT) and rapid disease diagnosis.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Minimization of Real-Time Polymerase Chain Reaction System
    Hwang, Ji Soo
    Kim, Yeo-Reum
    Park, Chan Young
    Song, Hye Jeong
    Kim, Yu Seop
    Kim, Jong Dae
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 124 : 7 - 7
  • [32] Real-Time Polymerase Chain Reaction A Revolution in Diagnostics
    Pabla, Simarjot Singh
    Pahla, Sarabjot Singh
    RESONANCE-JOURNAL OF SCIENCE EDUCATION, 2008, 13 (04): : 369 - 377
  • [33] Rickettsia prowazekii and real-time polymerase chain reaction
    Svraka, S
    Rolain, JM
    Bechah, Y
    Gatabazi, J
    Raoult, D
    EMERGING INFECTIOUS DISEASES, 2006, 12 (03) : 428 - 432
  • [34] Diagnosis of caprine mucopolysaccharidosis type IIID by real-time polymerase chain reaction-based genotyping
    Clavijo, Alfonso
    Sun, Feng
    Sneed, Loyd
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2010, 22 (04) : 622 - 627
  • [35] Real-time polymerase chain reaction based algorithm for differential diagnosis of Kinetoplastidean species of zoonotic relevance
    Munoz-Calderon, Arturo
    Wehrendt, Diana
    Cura, Carolina
    Gomez-Bravo, Andrea
    Abril, Marcelo
    Giammaria, Matilde
    Horacio Lucero, Raul
    Schijman, Alejandro G.
    INFECTION GENETICS AND EVOLUTION, 2020, 83
  • [36] Immunopolymerase chain reaction using real-time polymerase chain reaction for detection
    Sims, PW
    Vasser, M
    Wong, WL
    Williams, PM
    Meng, YG
    ANALYTICAL BIOCHEMISTRY, 2000, 281 (02) : 230 - 232
  • [37] On-chip, real-time, single-copy polymerase chain reaction in picoliter droplets
    Beer, N. Reginald
    Hindson, Benjamin J.
    Wheeler, Elizabeth K.
    Hall, Sara B.
    Rose, Klint A.
    Kennedy, Ian M.
    Colston, Bill W.
    ANALYTICAL CHEMISTRY, 2007, 79 (22) : 8471 - 8475
  • [38] Study of Optimal Real-time Polymerase Chain Reaction Chip by Comparison of Coating Reflective Materials
    Hwang, Ji-Soo
    Kim, Bo-Jun
    Kim, Jong-Dae
    Kim, Yu-Seop
    Song, Hye-Jeong
    Park, Chan-Young
    SENSORS AND MATERIALS, 2019, 31 (02) : 437 - 445
  • [39] Real-time polymerase chain reaction for diagnosis and quantitation of negative strand of chikungunya virus
    Chiam, Chun Wei
    Chan, Yoke Fun
    Loong, Shih Keng
    Yong, Sara Su Jin
    Hooi, Poh Sim
    Sam, I-Ching
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2013, 77 (02) : 133 - 137
  • [40] Real-time polymerase chain reaction for diagnosis and management of HIV-induced uveitis
    Selvaraj, Jayapratha R.
    Sudharshan, S.
    Therese, Lily K.
    Janani, M. K.
    Selvamuthu, Poongulali
    Rewri, Parveen
    Biswas, Jyotirmay
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (11) : 1634 - 1636