Exergoeconomic Evaluation of a Cogeneration System Driven by a Natural Gas and Biomass Co-Firing Gas Turbine Combined with a Steam Rankine Cycle, Organic Rankine Cycle, and Absorption Chiller

被引:3
|
作者
Liu, Ji [1 ]
Ren, Jie [2 ]
Zhang, Yujia [2 ]
Huang, Weilong [2 ]
Xu, Chen [2 ]
Liu, Lu [2 ]
机构
[1] Wuhan Business Univ, Sch Mech & Elect Engn, Wuhan 430056, Peoples R China
[2] Wuhan Univ Technol, Sch Naval Architecture Ocean & Energy Power Engn, Wuhan 430063, Peoples R China
关键词
cogeneration; biomass; natural gas; dual fuel gas turbine; exergoeconomic analysis; multi-objective optimization; WASTE HEAT-RECOVERY; THERMOECONOMIC MULTIOBJECTIVE OPTIMIZATION; WORKING FLUIDS; ENVIRONMENTAL-ANALYSES; THERMODYNAMIC ANALYSES; REFRIGERATION SYSTEMS; ZEOTROPIC MIXTURES; ECONOMIC-ANALYSIS; ENERGY; EXERGY;
D O I
10.3390/pr12010082
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Considering energy conversion efficiency, pollution emissions, and economic benefits, combining biomass with fossil fuels in power generation facilities is a viable approach to address prevailing energy deficits and environmental challenges. This research aimed to investigate the thermodynamic and exergoeconomic performance of a novel power and cooling cogeneration system based on a natural gas-biomass dual fuel gas turbine (DFGT). In this system, a steam Rankine cycle (SRC), a single-effect absorption chiller (SEAC), and an organic Rankine cycle (ORC) are employed as bottoming cycles for the waste heat cascade utilization of the DFGT. The effects of main operating parameters on the performance criteria are examined, and multi-objective optimization is accomplished with a genetic algorithm using exergy efficiency and the sum unit cost of the product (SUCP) as the objective functions. The results demonstrate the higher energy utilization efficiency of the proposed system with the thermal and exergy efficiencies of 75.69% and 41.76%, respectively, while the SUCP is 13.37 $/GJ. The exergy analysis reveals that the combustion chamber takes the largest proportion of the exergy destruction rate. The parametric analysis shows that the thermal and exergy efficiencies, as well as the SUCP, rise with the increase in the gas turbine inlet temperature or with the decrease in the preheated air temperature. Higher exergy efficiency and lower SUCP could be obtained by increasing the SRC turbine inlet pressure or decreasing the SRC condensation temperature. Finally, optimization results indicate that the system with an optimum solution yields 0.3% higher exergy efficiency and 2.8% lower SUCP compared with the base case.
引用
收藏
页数:28
相关论文
共 50 条
  • [31] Thermodynamic and thermoeconomic optimization of an integrated gas turbine and organic Rankine cycle
    Khaljani, M.
    Saray, R. Khoshbakhti
    Bahlouli, K.
    ENERGY, 2015, 93 : 2136 - 2145
  • [32] Real-gas effects in organic Rankine cycle turbine nozzles
    Colonna, P.
    Harinck, J.
    Rebay, S.
    Guardone, A.
    JOURNAL OF PROPULSION AND POWER, 2008, 24 (02) : 282 - 294
  • [33] The Role of Dense Gas Dynamics on Organic Rankine Cycle Turbine Performance
    Wheeler, Andrew P. S.
    Ong, Jonathan
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2013, 135 (10):
  • [34] Assessment and working fluid comparison of steam Rankine cycle -Organic Rankine cycle combined system for severe cold territories
    Zhang, Hong-Hu
    Li, Ming-Jia
    Feng, Yong-Qiang
    Xi, Huan
    Hung, Tzu-Chen
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [35] Performance analysis of a gas turbine combined cycle power plant with waste heat recovery in Organic Rankine Cycle
    Balanescu, Dan-Teodor
    Homutescu, Vlad-Mario
    12TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING (INTER-ENG 2018), 2019, 32 : 520 - 528
  • [36] Exergetic and exergoeconomic evaluation of co-firing biomass gas with natural gas in CCHP system integrated with ground source heat pump
    Zhang, Xiaofeng
    Zeng, Rong
    Mu, Kang
    Liu, Xiaobo
    Sun, Xiaoqin
    Li, Hongqiang
    ENERGY CONVERSION AND MANAGEMENT, 2019, 180 : 622 - 640
  • [37] Cogeneration system comprising back-pressure steam turbine generating unit coupled with organic Rankine cycle
    Liu, Q. (qiang-liu09@mails.tsinghua.edu.cn), 1600, Chinese Society for Electrical Engineering (33):
  • [38] Thermo-economic assessment of an externally fired hybrid CSP/biomass gas turbine and organic Rankine combined cycle
    Pantaleo, Antonio M.
    Camporeale, Sergio M.
    Miliozzi, Adio
    Russo, Valeria
    Mugnozza, Giacomo Scarascia
    Markides, Christos N.
    Shah, Nilay
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 174 - 181
  • [39] Externally Fired Micro-Gas Turbine and Organic Rankine Cycle Bottoming Cycle: Optimal Biomass/Natural Gas Combined Heat and Power Generation Configuration for Residential Energy Demand
    Camporeale, Sergio Mario
    Ciliberti, Patrizia Domenica
    Fortunato, Bernardo
    Torresi, Marco
    Pantaleo, Antonio Marco
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2017, 139 (04):
  • [40] Exergoeconomic and Exergoenvironmental Analysis of a Novel Power and Cooling Cogeneration System Based on Organic Rankine Cycle and Ejector Refrigeration Cycle
    Tao, Jinke
    Wang, Huitao
    Wang, Jianjun
    Feng, Chaojun
    ENERGIES, 2022, 15 (21)