Shaking Table Testing of a Scaled Nuclear Power Plant Structure with Base Isolation

被引:0
|
作者
Song, Linlin [1 ,2 ]
Zhang, Xueming [1 ,2 ]
Wei, Mingyang [1 ,2 ]
Sun, Yunlun [3 ]
Chen, Shicai [4 ]
Chen, Yan [3 ]
机构
[1] Shijiazhuang Tiedao Univ, Minist Educ, Key Lab Rd & Railway Engn Safety Control, Shijiazhuang 050043, Peoples R China
[2] Shijiazhuang Tiedao Univ, State Key Lab Mech Behav & Syst, Safety Traff Engn Struct, Shijiazhuang 050043, Peoples R China
[3] Chinergy Co Ltd, Beijing 100193, Peoples R China
[4] Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
SEISMIC ISOLATION; RISK-ASSESSMENT; SYSTEMS;
D O I
10.1155/2023/2536474
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To investigate the seismic performance and isolation effect of a high-temperature gas-cooled reactor, a 1/20 scale model including a reactor, a spent-fuel plant, and a nuclear auxiliary plant was fabricated. In addition, 220 mm lead-rubber bearings were designed and produced for use in the shaking table test, which included both isolated and nonisolated conditions. Two historical earthquake records and three artificial earthquake motions were used to input the ground motion in the tests. The results demonstrated that the seismic performance of the plant was better and that the structure was in an elastic state, under a safe shutdown earthquake event. Isolation bearings were found to effectively reduce the dominate frequency of the structure. The acceleration amplification factor of the superstructure was found to be less than 1. The isolation test results showed that the peak of the floor response spectrum at the pressure vessel support was less than 0.1 g. In the nonisolation test, the peak of the floor response spectrum was greater than 1 g. In the isolation test, the relative displacement of the structure was less than 1.1 mm, which was relatively small. The structure maintained a good isolation performance and exhibited improved safety under extreme ground motion.
引用
收藏
页数:23
相关论文
共 50 条
  • [21] Shaking table testing of two storey As-Built and retrofitted scaled URM buildings
    Giaretton, Marta
    Ingham, Jason M.
    Dizhur, Dmytro
    STRUCTURES, 2022, 41 : 260 - 269
  • [22] Shaking table tests of a scaled bridge model with rolling-type seismic isolation bearings
    Tsai, Meng-Hao
    Wu, Si-Yi
    Chang, Kuo-Chun
    Lee, George C.
    ENGINEERING STRUCTURES, 2007, 29 (05) : 694 - 702
  • [23] Seismic analysis of soil-structure system of nuclear power plant on non-rock site via shaking table test
    Wang Xiaohui
    Li Xiaojun
    Liu Aiwen
    He Qiumei
    Hou Chunlin
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2020, 136 (136)
  • [24] Shaking Table Tests of the Smart Restorable Sliding Base Isolation System (SRSBIS)
    Cardone, Donatello
    Narjabadifam, Peyman
    Nigro, Domenico
    JOURNAL OF EARTHQUAKE ENGINEERING, 2011, 15 (08) : 1157 - 1177
  • [25] Influences of base isolation system on seismic resistance of nuclear power plant containment
    Institute of Earthquake Engineering, Dalian University of Technology, Dalian
    Liaoning
    116024, China
    Zhao, Chun-Feng, 1600, Explosion and Shock Waves (34):
  • [26] Shaking Table Tests of the Cable Tray System in Nuclear Power Plants
    Huang, Baofeng
    Lu, Wensheng
    Mosalam, Khalid M.
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2017, 31 (04)
  • [27] Shaking table model tests of concrete containment Vessel (CCV) for CPR1000 nuclear power plant
    Liu, Jun
    Kong, Jianwei
    Kong, Xianjing
    PROGRESS IN NUCLEAR ENERGY, 2016, 93 : 186 - 204
  • [28] Analyses of Pile-Supported Structures with Base Isolation Systems by Shaking Table Tests
    Song, Sumin
    Jeong, Sangseom
    BUILDINGS, 2024, 14 (05)
  • [29] Shaking table test and numerical simulation study on base rocking isolation bridge piers
    Guo Z.
    Chen Y.
    He K.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (06): : 38 - 48
  • [30] Shaking table study of a large-scale thermal power plant building equipped with innovative damping and isolation techniques
    基于振动台试验的火电厂主厂房减隔震体系抗震性能研究
    Dai, Kaoshan, 1600, Chinese Society of Civil Engineering (53): : 227 - 232